• Title/Summary/Keyword: 비교항목 측정치

Search Result 95, Processing Time 0.022 seconds

Comparison of 3D Scanned Anthropometric Data between Korean and American Adults by using Ratios and Indices (지수치를 활용한 한국과 매국 성인 3차원 인체치수 비교)

  • Yi, Kyong-Hwa;Istook, Cynthia
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.6
    • /
    • pp.959-967
    • /
    • 2008
  • The body measurement ratios and indices used in this study are all 3D female measurement data of the two countries were obtained from Size Korea Project and SizeUSA Project. The purpose of the study is to compare and analyze body measurement data between two countries. The results of this research are helpful for the clothing manufacturer and company to trade with America. The samples were 1,988 Korean and 6,306 American females. Thirty-five body measurement ratios and indices were chosen as the principal measurements in making garments. The conclusion of this research was as follow; First, U.S. females have measurements that exceed Korean women, except for crotch length total and shoulder slope. Second, the correlation coefficients of height and weight are relatively higher than other measurements in the two countries' body measurements. Finally, American women's height ratios are significantly bigger than Korean women's in most height ratios. On the other hand, Korean are significantly bigger than American in weight ratios. The drop values of Korean females are also smaller than those of American. It was recognized that American women are much bigger, wider and more obese than Korean according to the results by utilizing the girth ratios. BMI, Rohrer and Vervaeck index.

A Study on Knowledge-based Alternatives Analysis Model(KAAM) for the Best Decision Making in Weapon Systems Acquisition (무기체계 획득시 최적 의사결정을 위한 지식기반 대안분석모델(KAAM) 연구)

  • Park, Kwang-Woong;Lee, Kang-Yeong;Kim, Chi-Han;Choi, Sang-Young
    • Journal of the military operations research society of Korea
    • /
    • v.33 no.1
    • /
    • pp.1-18
    • /
    • 2007
  • In the early stage of weapon system acquisition process, acquisition policy is necessarily established to acquire weapon system in a faster, better, cheaper way. Several alternatives, such as "buy", "domestic research and development", and "technical corporative production", can be considered for the best acquisition policy making. However, the comparison factors for those alternatives have different metrics and values. Therefore, the aim of this paper is to suggest KAAM(Knowledge-based Alternatives Analysis Model) as a scientific method to compare the alternatives having such different metrics and values and giving a weighted and normalized single measurement for the easy comparison. KAAM is a hybrid model incorporating Satty technique, Delphi/Shang method, Consensus method, and SAW method. KAAM is implemented on Microsoft Excel environment and provided tabular form user interface. Finally, an illustrative example is shown using KAAM.

An Examination of Expectation as a Comparison Standard in Measuring Service Quality in the Hospitality Industry (환대산업에서 서비스 품질 측정을 위한 표준치와 기대치의 비교)

  • Yoon, Tae-Hwan;Kim, Ki-Young
    • Culinary science and hospitality research
    • /
    • v.8 no.2
    • /
    • pp.19-35
    • /
    • 2002
  • 본 연구는 서비스업에서 서비스 품질을 측정하는 것에 있어서 표준과 기대치에 관한 비교다. 외식산업에서의 기대의 개념은 서비스 품질을 측정한다는 것으로 이를 표준화하기 위해 광범위하게 사용되었다. 그러나, 서비스 품질 측정에 있어서 기대치가 당위성과 신뢰성에 의해 많은 연구자들에 의해 비평되었다. 이 연구의 목적은 기대치에 통한 서비스업에서의 서비스 품질을 측정한다는 것이다. 본 연구는 다음과 같은 한계점을 가진다. 첫째로, 연구의 표본수가 적기 때문에 분석에 있어서 신뢰성이 떨어졌다. 둘째, 한정된 한국의 호텔을 이용했던 여행자에 한하여 설문을 했기 때문에 객관성이 결여될 수가 있다. 셋째, 총체적인 서비스 품질과 고객 만족의 측정은 하나의 항목 저울과 이와 같이 그것을 사용하면서 수행되었기 때문에 이들의 신뢰성을 추정하는 것이 불가능했다. 연구결과 소비자가 서비스의 평가를 위한 비교 기준으로서 기대치에 대한 4개의 다른 수준을 가진 요인을 사용하였다. 본 연구에 있어서 기대의 개념이 고객 만족에 서비스 품질보다 관계가 높다는 것을 밝힌다.

  • PDF

Comparative Analysis of Korean and American Body Sizes & Shapes using 3D Scanned Anthropometric Data (한국과 미국 성인의 3차원 인체 치수 비교)

  • Yi, Kyong-Hwa;Istook, Cynthia;Kang, Yeo-Sun;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.892-901
    • /
    • 2007
  • This research is the initial step for establishing a convertible body sizing table applicable to the Korean and American female apparel industry. All 3D female measurement data of the two countries were obtained from Size Korea Project and SizeUSA Project. The sample subjects used in this study were 1,988 Korean and 6,306 American females. Thirty-four(34) variables were chosen as the principal measurements in making garments. The conclusion of this research was as follow: First, it was determined that American women were larger and longer than Korean women in all measurement except shoulder slope measurement. Second, according to the differences analysis of the each age group in Korean Females, all measurements except hip girth had significant differences among the age groups. In case of American females, all measurements except arm length(shoulder to wrist) had significant differences among the age groups. Third, in the comparison of differences between the age groups of the two countries' women, some dimensions varied significantly with age, while others did not show any statistical significance among the age groups. Fourth, according to the t-tests of same age groups between Korean & American female measurements, American female measurements were larger and longer than Korean in all measurements except crotch length total, shoulder slope, hip girth-bust girth and hip girth-waist girth.

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

A Study of Facial Asymmetry and Masticatory Pattern Using Panorama and PA Cephalograph. (파노라마 및 정모방사선사진을 이용한 저작형태에 따른 안면비대칭에 관한 연구)

  • Lee, You-Mee;Kim, Jae-Chang
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.2
    • /
    • pp.167-176
    • /
    • 2006
  • Recent studies have shown that there are significant increasing facial asymmetry using 3-dimensional imaging. This study use panorama view and PA cephalograph that were low in price and make good use in dentistry. For this study, 35 persons without remarkable malocclusion were selected, they had panorama view and PA cephalograph, make written questionnaire about facial asymmetry cognition and masticatory pattern. Data obtained were statistically processed by the SPSS Windows program and the results of this study were as follows: 1. There were significant difference between Rt and Lt. on Co-Go, Co-Ag, Co-Go-Ag, Go-Me- Ag. 2. In panorama view, There were significant difference between Rt. and Lt Co-Ag that chewing right side, Rt. and Lt. Co-Go that chewing left side, 3. In PA cephalograph view, There were significant difference in Rt. and Lt. Cg-Go, Rt. and Lt. Co-Ag that chewing right side, Rt. and Lt. Cg-Go that chewing left side 4. There were significant difference in Rt. and Lt. Co-Go, CO-si-CR, go-ME-Ag that cogniting facial asymmetry.

ASSESSMENT OF DENTAL ANXIETY IN THE CHILD PATIENT BY THEIR DRAWINGS (환아의 그림을 통한 치과치료시 불안도 평가)

  • Choi, Seo-Jung;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.354-362
    • /
    • 2003
  • The aim of the present study was to establish validity for Dental Anxiety Scale in children by their drawings. Dental treatment was provied for 35 children in the ages of 4 to 8, using the quadrant approach. The children's anxiety arising during dental treatment was measured by Modified Sheskin's Criteria(Dental Anxiety Scale, DAS). After reliability analysis of Dental Anxiety Score, it was compared with Faces Pain Scale and was tested for their correlation. Thereafter the several factors having an effect on Dental Anxiety Scale were examined. A significant correlation(r=0.2610) was found between the two scales and Dental Anxiety Scale was high significantly in 4-6 score of Faces Pain Scale. The findings suggested that the Dental Anxiety Scale is a valid means of assessing child dental anxiety status in a clinical context and the Dental Anxiety Scale can be affected by 'Age', 'Gender' and 'Reaction in the past'.

  • PDF

Comparision of two cephalometric superimposition methods - Nasion-sella line method and Anterior cranial base method (두가지 두부 방사선 사진 중첩 방법의 비교 - Nasion-Sella line 중첩과 Anterior cranial base 중첩)

  • Kyung, Seung-Hyun;Moon, Yon-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.633-641
    • /
    • 1997
  • Spatial change of craniofacial structures from growth or orthopedic force is usually evaluated by cephalometric superimpositions at different points in time.As the evaluation cu be changed according to cephalometric superimposition method,selettion for correct superimposition method is very important.Double registration of nineteen pairs of female lateral head films,their growth period is average 3.7 years and age is overage 10.7 years,were performed by two observers.Comparisions was made between two methods and the results revealed the following, 1. NS line and ACB superimpositions ate not markedly different in reliability due to almost same registration error of them. 2. The investigation was undertaken to examine interobserver difference.In NS line method, there is no significance in all measurements. In ACB method,significant difference was revealed in 4 measurements of 7 measurements was 3. In the investigation of intermethod difference, there is no significance between NS line and ACB superimpositions

  • PDF

기준 베타선 흡수선량 비교 측정

  • 김정묵;장시영;이기창
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.23-27
    • /
    • 1996
  • $\beta$-선 흡수선량의 1차 표준이 확립되지않은 상황에서 측정표준이 이미 확립된 외국의 표준기관에서 검증되어 도입된 $\beta$-선 흡수선량 조사시설에 대해 ISO-6980에서 명시한 항목에 대해 성능실험을 수행하였고, 외삽형전리함을 사용하여 측정된 이온화전류로 부터 흡수선량률을 재평가하여 외국의 검증결과와 비교하였다. 조사시설의 성능실험 결과 Sr$^{90}$ +Y$^{90}$ 선원에 대해 선원으로부터 30cm거리에서 빔 균일도, 제동복사선 기여도 및 $\beta$-선 최대잔여에너지가 기준에 적합한 것으로 나타났다. 그리고 흡수선량 평가결과는 '96. 4. 1을 기준으로하여 20 $^{\circ}C$,1기압에서 2.686 ($\pm$2.73%)$\mu$Gy/sec로 외국표준기관의 측정치와 1.8%이내에서 일치하는 것으로 나타났다.

  • PDF

A Prediction of $CO_2$ Concentration and Measurement of Indoor Air Quality in the EMU (전동차 실내공기질 측정 및 $CO_2$ 농도 예측)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.4
    • /
    • pp.378-383
    • /
    • 2008
  • In December 2006, the Ministry of Environment Republic of Korea established the guideline which is "Indoor Air Quality Management Guidelines in Public Transportation." as control items, $CO_2$ (carbon dioxide) and PM10 (particle matter) are classified two categories, that is, Level 1 (non-rush hour), Level 2 (rush hour). Therefore, the quality of air in train and subway should be controlled in accordance with the guideline. We took a measure the air freshness inside train twice at Line 4 (Tangogae-Oido), in Sep. 2007 and at Line 1 (Dongincheon-Yongsan) in Nov. 2007, respectively and, also expected the emitted $CO_2$ concentration by using a property of matter such as EMU (Electric Multiple Unit) design reviewing specification and air. According to the measured values, the concentration of PM10 was 44, 57, 45% and the concentration of $CO_2$ was 39, 36, 44% respectively, all measured values are within the guideline and also, as a result we found the expected value and measured value are similar.