• Title/Summary/Keyword: 비강

Search Result 597, Processing Time 0.022 seconds

A Review on Physical Activity for Health Care in the Era of COVID-19 (COVID-19 시대의 건강관리를 위한 신체활동 고찰)

  • Yoo, Jae-Hyun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.2
    • /
    • pp.149-157
    • /
    • 2021
  • One year has passed since the pandemic of COVID-19, which occurred in Wuhan, China, in November 2019 began. Worldwide, as of January 2021, more than 95 million people have been infected, and the death toll is higher than 2 million. In Korea, there are 74,262 infected and 1,328 dead, and government policies such as social distancing to prevent infection are being implemented. Accordingly, many inconveniences occurred in the physical activity environment, such as the closure of various sports facilities. It was necessary to consider physical activities to maintain healthy life while cooperating with the national policy while preventing infection. This study investigated the benefits of physical activity to reduce the risk of trichomoniasis and diabetes, improve bone mineral density, prolong healthy lifespan, maintain activity performance with aging, and improve psychological anxiety and depression. In addition, the physiological changes that may occur in the situation of stopping exercise due to social distancing to prevent COVID-19 infection were reviewed. In addition, moderate-intensity exercise that helps strengthen immune function by activating natural killer cells, neutrophils, and antibody responses was investigated. In addition, it reduces the level and function of blood B-cells, T-cells, and natural killer cells for several hours, decreases phagocytosis of neutrophils in the nasal cavity, increases inflammatory cytokines, decreases immune function, and increases infection. High-intensity exercise was considered. Therefore, in the age of COVID-19, long-term high-intensity exercise such as marathon, which causes impaired immune function, should be refrained from. And you should do moderate-intensity regular aerobic exercise such as fast walking to help prevent infection. It is also recommended to participate in resistance exercises to prevent loss of muscle mass.

Analysis of ROX Index, ROX-HR Index, and SpO2/FIO2 Ratio in Patients Who Received High-Flow Nasal Cannula Oxygen Therapy in Pediatric Intensive Care Unit (고유량 비강 캐뉼라 산소요법을 받은 소아중환자실 환아의 ROX Index와 ROX-HR Index 및 SpO2/FIO2 Ratio분석)

  • Choi, Sun Hee;Kim, Dong Yeon;Song, Byung Yun;Yoo, Yang Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.53 no.4
    • /
    • pp.468-479
    • /
    • 2023
  • Purpose: This study aimed to evaluate the use of the respiratory rate oxygenation (ROX) index, ROX-heart rate (ROX-HR) index, and saturation of percutaneous oxygen/fraction of inspired oxygen ratio (SF ratio) to predict weaning from high-flow nasal cannula (HFNC) in patients with respiratory distress in a pediatric intensive care unit. Methods: A total of 107 children admitted to the pediatric intensive care unit were enrolled in the study between January 1, 2017, and December 31, 2021. Data on clinical and personal information, ROX index, ROX-HR index, and SF ratio were collected from nursing records. The data were analyzed using an independent t-test, χ2 test, Mann-Whitney U test, and area under the curve (AUC). Results: Seventy-five (70.1%) patients were successfully weaned from HFNC, while 32 (29.9%) failed. Considering specificity and sensitivity, the optimal cut off points for predicting treatment success and failure of HFNC oxygen therapy were 6.88 and 10.16 (ROX index), 5.23 and 8.61 (ROX-HR index), and 198.75 and 353.15 (SF ratio), respectively. The measurement of time showed that the most significant AUC was 1 hour before HFNC interruption. Conclusion: The ROX index, ROX-HR index, and SF ratio appear to be promising tools for the early prediction of treatment success or failure in patients initiated on HFNC for acute hypoxemic respiratory failure. Nurses caring for critically ill pediatric patients should closely observe and periodically check their breathing patterns. It is important to continuously monitor three indexes to ensure that ventilation assistance therapy is started at the right time.

A Fundamental Study on Mode of Operation for Maritime Autonomous Surface Ship(MASS) - Based on review of IMCA M 220

  • Jeong-Min Kim;HyeRi Park
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.5
    • /
    • pp.163-170
    • /
    • 2023
  • As the development of the 4th industrial revolution in the maritime industry has accelerated, the technical development and progress of maritime autonomous surface ship(MASS), and the development of international regulations have been accelerated. In particular, the IMO Maritime Safety Committee(MSC) has established a road-map for the development of the non-mandatory goal-based MASS instrument(MASS Code) and started developing a non-mandatory MASS Code at MSC 105th meeting. Many countries are actively participating in the Correspondence Group on the development of MASS Code, and the development of detailed requirements for MASS functions in the MASS Code is underway. Especially, the concept of "Mode of Operation" for MASS functions was mentioned in the Correspondence Group for the first time, and it is expected that discussions on these modes will be conducted from the IMO MASS JWG meeting to held in April 2023. The concept of "Mode of Operation" will be useful in explaining MASS and MASS functions and will be discussed continually for the development of MASS Code. This paper reviews the contents of the IMCA M 220 document, which provides guidelines on operating modes, to conduct research on the benchmark for setting the operating modes of MASS.

Test Evaluation of a Linerless Composite Propellant Tank Using the Composite Collapsible Mandrel (복합재 분리형 맨드릴을 이용한 라이너 없는 복합재 추진제 탱크에 대한 시험 평가)

  • Seung Yun Rhee;Kwangsoo Kim;Young-Ha Yoon;Moo-Keun Yi;Hee Chul Kim
    • Composites Research
    • /
    • v.36 no.2
    • /
    • pp.132-139
    • /
    • 2023
  • A linerless composite propellant tank was designed and manufactured by using the carbon fiber-reinforced composite materials which have superior strength-to-weight ratio in order to reduce weight of the tank. In this research, we designed a sub-scale composite propellant tank with a diameter of 800 mm to withstand an MEOP of 1.7 MPa. We manufactured the boss of the tank by using the same composite materials to reduce the thermal expansion difference between the boss and the secondary-bonded composite layers of the barrel in the cryogenic environment. We used the collapsible mandrel to manufacture the tank without any liner. The mandrel was made from epoxy-based composite tooling prepregs to reduce weight of the mandrel. We manufactured the test tanks by laying up the carbon fiber fabric prepregs manually on the mandrel and then applying the autoclave cure process. We performed a proof test, a helium tightness test, a repeated pressurization test, and a burst test in room temperature. The test results demonstrate that the proposed design and manufacture process satisfies all strength requirements as well as an anti-leakage requirement.

Evaluation of Applicability of Customized Bolus According to 3D Printer Material Characteristics (3D 프린터 소재 특성에 따른 맞춤형 볼루스의 적용성 평가)

  • Kyung-Tae Kwon;Hui-Min Jang;Myeong-Seong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1091-1097
    • /
    • 2023
  • Bolus is used in radiation therapy to prescribe an even dose to the tumor when the skin surface is inclined or has irregularities. At this time, the dose to the skin surface increases. Due to the patient's unique body structure and irregular skin, voids may occur between the bolus and the skin, which may reduce the accuracy of treatment. Therefore, in this study, the existing bolus and the self-produced bolus through 3D printing were applied to the nasal area, and the difference between the surface dose after treatment plan and the dose directly measured with an Optically Stimulated luminescence(OSL) dosimeter was compared to the existing bolus. The bolus rate was 97%, PLA 100.33%, ePETELA 75A 100.53%, and ePETELA 85A 100.36%. It was confirmed that there was little error in the measurement values and treatment plan values for each material. In addition, compared to when applying a conventional bolus, a difference of -3% to +0.5% for a 3D printed bolus can be confirmed, so a customized bolus produced through 3D printing can complement the shortcomings of the existing bolus. It is believed that there will be.

Comparative Morphology and Morphometry of the Olfactory Organ of Carassius auratus and Carassius cuvieri (Cypriniformes, Cyprinidae) (붕어 Carassius auratus와 떡붕어 Carassius cuvieri 후각기관의 형태 및 형태계측학적 비교 연구)

  • Hyun-Tae Kim;Jin-hui Lee
    • Korean Journal of Ichthyology
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2023
  • The olfactory organ of Carassius auratus and C. cuvieri was compared morphologically and morphometrically using stereomicroscopy and statistical program (SPSS version 18.0). The external morphology of the olfactory organ consists of the open semicircular anterior and posterior nostril, and nasal flap. The internal structure showed the oval rosette consisting of several lamellae arranged radiately. In statistical analysis of standard length (SL), olfactory lamellar number (LN), and SL/LN ratio between two species using independent two sample t-test and Pearson's correlation and coefficient, C. cuvieri is the longer SL than that of C. auratus and C. auratus LN (14~20) is lager than that of C. cuvieri (14~16) (P<0.001) and C. auratus LN/SL ratio (12.7±0.7%) is larger than that of C. cuvieri (8.2±0.6%). These results suggest that i) open semicircular nostrils is functional morphology to offset the boundary layer and ii) the lager LN of smaller C. auratus may be a morphological adaptation to reflect its higher olfactory dependence than C. cuvieri and iii) such interspecific difference in LN and LN/SL ratio could be applied as a new taxonomic trait for identification.

Recurrence Analysis after Video-assisted Thoracic Surgery for the Treatment of Spontaneous Pneumothorax (자연기흉의 비디오흉강경수술 후 재발에 대한 분석)

  • Kim, Sung-Wan;Kim, Duk-Sil;Lim, Chang-Young;Lee, Hyeon-Jae;Lee, Gun;Kong, Joon-Hyuk
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.710-715
    • /
    • 2010
  • Background: Video-assisted thoracic surgery (VATS) became common in the treatment of spontaneous pneumothorax (SP). Therefor we've reviewed the recurrence rate after VATS and analysed the factors affecting recurrent pneumothorax after VATS on this study. Material and Method: This retrospective analysis was performed on 321 patients of SP who had undergone VATS from Jan. 2001 to Dec. 2008. The two groups were divided as follow: group A, non-recurrent group (298 patients: 93%); and group B, recurrent group (26 patients: 7%); the two groups were analysed retrospectively. Result: The average age of the study groups were $20.9{\pm}4.3$ years old in recurrent group vs. $25.9{\pm}11.7$ years old in non-recurrent group with statistical significance (p < 0.05). There were no statistical significance in male to female ratio, height/weight ratio, location of pneumothorax, smoking history, operative time, duration of drain, hospital stay, indication of opertion and incidence rate. Average length of duration in recurrence was 12.9 months. There was 22 (95.7%) recurrent patients after VATS within 4 year period among recurrent group. Treatment methods in 23 of recurrent patients were, 8 (VATS), 2 (Axillary thoracotomy) with 15% or more in amount of pneumothorax and 7 (7 Fr. chest tube), 6 (nasal 02) with 15% or less in amount of pneumothorax. Among 10 cases of reoperation, there were 3 cases of over looking type and 7 cases of new growing type. There was no additional recurrence after these procedures were given. Conclusion: There was higher recurrence rate in younger age after VATS thus for those under 20 yrs old, detailed and possible preoperative warning for recurrence is warranted. Most recurrence occured within 4 year period, thus for this reason, regular interval based follow up with chest x-ray study is suggested during this period.

Effects of Horseshoe Expander (Horseshoe Expander의 확장 효과에 관한 연구)

  • Chung, Kyu-Rhim;Park, Young-Guk;Lee, Young-Jun;Kim, Hong-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.553-563
    • /
    • 2000
  • Horseshoe Expander is one of Slow Maxillary Expansion(SME) which aims to accommodate the contra- lateral expansion and midpalatal suture expansion or the palate. The appliance consists of skeleton type strew embedded in split Horseshoe appliance. It is the objectives of the presentation to manifest the changes in dental & craniofacial components subsequent to the application of Horseshoe Expander. The subjects for this study consisted of 32 patients (mean age : 12.7). frontal, lateral cephalometric headfilm were taken and study casts were fabricated before and after expansion. 24 items were measured, compared preexpansion with postexpansion. Especially, palatal volume was measured by means of 'Hydro-measurement method'. Tooth axis measurement on the dental casts were made with Universal bevel protractor, and Horseshoe Expander group were compared with RME group. This study of changes to maxillary expansion with Horseshoe Expander revealed the following significant results. 1. Triangular-shaped expansion pattern appeared in frontal cephalometric headfilm. 2. Palatal plane, occlusal plane, mandibular plane and upper incisor to FH increased in lateral cephalometrir headfilm. 3. Palatal volume increased significantly. A slight bite opening, reduction of occlusal contact points showed in dental casts. 4. A 2.2:1 ratio of the amount of intermolar width in maxilla(orthodontic movement) to maxillary width (orthopedic movement) was determined. 5. Horseshoe Expander group has less buccal tipping tendency than RME group, by taking high correlation coefficients in the upper second premolar and first molar. It was suggested that Horseshoe Expander showed less orthodontic changes, less buccal tipping tendency. In addition, it was effective in maxillary expansion.

  • PDF

Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite (COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증)

  • Moon, Yun Seob;Lee, Kangyeol
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.420-433
    • /
    • 2016
  • The purpose of this study is to improve the calibration matrixes of 2-D and 3-D convective rainfall rates (CRR) using the brightness temperature of the infrared $10.8{\mu}m$ channel (IR), the difference of brightness temperatures between infrared $10.8{\mu}m$ and vapor $6.7{\mu}m$ channels (IR-WV), and the normalized reflectance of the visible channel (VIS) from the COMS satellite and rainfall rate from the weather radar for the period of 75 rainy days from April 22, 2011 to October 22, 2011 in Korea. Especially, the rainfall rate data of the weather radar are used to validate the new 2-D and 3-DCRR calibration matrixes suitable for the Korean peninsula for the period of 24 rainy days in 2011. The 2D and 3D calibration matrixes provide the basic and maximum CRR values ($mm\;h^{-1}$) by multiplying the rain probability matrix, which is calculated by using the number of rainy and no-rainy pixels with associated 2-D (IR, IR-WV) and 3-D (IR, IR-WV, VIS) matrixes, by the mean and maximum rainfall rate matrixes, respectively, which is calculated by dividing the accumulated rainfall rate by the number of rainy pixels and by the product of the maximum rain rate for the calibration period by the number of rain occurrences. Finally, new 2-D and 3-D CRR calibration matrixes are obtained experimentally from the regression analysis of both basic and maximum rainfall rate matrixes. As a result, an area of rainfall rate more than 10 mm/h is magnified in the new ones as well as CRR is shown in lower class ranges in matrixes between IR brightness temperature and IR-WV brightness temperature difference than the existing ones. Accuracy and categorical statistics are computed for the data of CRR events occurred during the given period. The mean error (ME), mean absolute error (MAE), and root mean squire error (RMSE) in new 2-D and 3-D CRR calibrations led to smaller than in the existing ones, where false alarm ratio had decreased, probability of detection had increased a bit, and critical success index scores had improved. To take into account the strong rainfall rate in the weather events such as thunderstorms and typhoon, a moisture correction factor is corrected. This factor is defined as the product of the total precipitable waterby the relative humidity (PW RH), a mean value between surface and 500 hPa level, obtained from a numerical model or the COMS retrieval data. In this study, when the IR cloud top brightness temperature is lower than 210 K and the relative humidity is greater than 40%, the moisture correction factor is empirically scaled from 1.0 to 2.0 basing on PW RH values. Consequently, in applying to this factor in new 2D and 2D CRR calibrations, the ME, MAE, and RMSE are smaller than the new ones.

The Effect of Oxygen Therapy on VPB in Patients with Chronic Obstructive Pulmonary Disease (만성 폐쇄성 폐질환 환자에서 심실 조기수축에 대한 산소치료의 효과)

  • Shin, Kyu-Suck;Ko, Jeong-Seok;Kim, Seo-Jong;So, Kun-Ho;Jin, Gyo-Hyun;Lee, Keun;Lee, Gwi-Lae;Roh, Yong-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.42-49
    • /
    • 1999
  • Background: In patients with chronic obstructive pulmonary disease(COPD). it is well known that hypoxemia increases the frequency of VPB, which is associated with the poor prognosis such as sudden death. The aim of this study is to evaluate the effect of short and long-term low flow oxygen therapy on the development of VPBs in patients with COPD by correcting the hypoxemia. Method: In 19 patients with COPD, oxygen saturation and VPB's were monitored by pulse oxymeter and 24-hour Holter EKG, with room air and oxygen saturation and VPB's were monitored on the 1st and on the 8th day during oxygen therapy with nasal prong (2L/min). Results : The arterial oxygen saturation was significantly higher on the 1st day of oxygen therapy compared with breathing room air, and was also higher on the 8th day of oxygen therapy than on the 1st day. We found that there was significant correlation between the lowest value of the arterial oxygen saturation and the mean value of the arterial oxygen saturation. The number of VPB's per hour was significantly lower on the 1st day of oxygen therapy compared with breathing room air, and also lower on the 8th day of oxygen therapy than on the 1st day. Our results showed positive correlation between the decrease in the frequency of VPB's and the increase in the lowest arterial oxygen saturation, even though correlation was not significant(p=0.056). Conclusion: With oxygen therapy, the arterial oxygen saturation was increased and the number of VPB's was decreased. Long-term oxygen therapy more than 7days, would be helpful to decrease the number of VPB' s in patients with COPD.

  • PDF