• Title/Summary/Keyword: 비가역성

Search Result 64, Processing Time 0.018 seconds

Changes of Glutamate and Polyamine Levels of Hippocampal Microdialysates in Response to Occlusion of Both Carotid Arteries in Mongolian Gerbils (뇌허혈 손상에 있어서 해마-세포외액내 Glutamate와 Polyamine 농도의 변동에 관한 연구)

  • Shin, Kyung-Ho;Kim, Hyung-Gun;Choi, Sang-Hyun;Cho, So-Hyun;Chun, Yeon-Sook;Chun, Boe-Gwun
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.3
    • /
    • pp.273-289
    • /
    • 1994
  • Reversible brain ischemia was produced by occluding both common carotid arteries for 5 min, and the effects of aminoguanidine (AG), $DL-{\alpha}-difluoromethylornithine$ (DFMO), MK-801, and nimodipine (NM) on the ischemia induced changes of the polyamine, glutamate and acetylcholine levels in the hippocampus CA1 subfield and the specific $[^3H]\;MK-801$ binding to the hippocampus synaptosomal membranes were studied with a histological reference of the cresyl violet stained hippocampus. The basal putrescine level $(PT:\;74.4{\pm}8.8\;nM)$ showed a rapid increase (up to 1.7 fold) for 5 min of ischemia, remained significantly increased for 6 h, and then resumed the further increase to amount gradually up to about 3 fold 96 h after recirculation. However, the level of spermidine was little changed, and the spermine level showed a transient increase during ischemia followed by a sustained decrease to about 40% of the preischemic level after recirculation. The increase of PT level induced by brain ischemia was enhanced with AG or MK-801, but it was reduced by DFMO or NM. The basal glutamate level $(GT:\;0.90{\pm}0.l4\;{\mu}M)$ rapidly increased to a peak level of $8.19{\pm}1.14\;{\mu}M$ within 5 min after onset of the ischemia and then decreased to the preischemic level in about 25 min after recirculation. And NM reduced the ischemia induced increase of GT level by about 25%, but AG, DFMO and MK-801 did not affect the GT increase. The basal acetylcholine level $(ACh:\;118.0{\pm}10.5\;{\mu}M)$ did little change during/after brain ischemia and was little affected by AG or NM. But DFMO and MK-801, respectively, produced the moderate decrease of ACh level. The specific $[^3H]\;MK-801$ binding to the hippocampus synaptosomal membrane was little affected by brain ischemia for 5 min. The control value (78.9 fmole/mg protein) was moderately decreased by AG and MK-801, respectively but was little changed by DFMO or NM. The microscopic findings of the brains extirpated on day 7 after ischemia showed severe neuronal damage of the hippocampus, particularly CA1 subfield. NM and AG moderately attenuated the delayed neuronal damage, and DFMO, on the contrary, aggravated the ischemia induced damage. However, MK-801 did not protect the hippocampus from ischemic damage. These results suggest that unlike to the mode of anti-ischemic action of NM, AG might protect the hippocampus from ischemic injury as being negatively regulatory on the N-methyl-D-aspartate (NMDA) receptor function in the hippocampus.

  • PDF

Changes of Sputum Matrix Metalloproteinases and Tissue Inhibitor of Matrix Metalloproteinase-1 by Antibiotic Treatment in Acute Exacerbation of Chronic Bronchitis (만성 기관지염의 급성 악화에서 항생제 투여에 의한 유도객담 내 Matrix metalloproteinase와 Tissue inhibitor of matrix metalloproteinase의 변화)

  • Yoon, Hyoung-Kyu;Ahn, Joong-Hyun;Kim, Chi-Hong;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.420-430
    • /
    • 2002
  • Background : Excessive extracellular matrix (ECM) deposition by airway inflammation is presumed to play an important role in the pathogenesis of worsening airflow obstruction (Ed- acceptable three-word noun) seen during acute exacerbations of chronic bronchitis. Although many proteases can cleave ECM molecules, matrix metalloproteinases (MMPs) and their inhibitors are likely to be the physiologically relevant mediators of ECM degradation. Objectives ; The purpose of this study was to demonstrate that antibiotic treatment can change airway MMPs and TIMP-1 concentrations/levels by controlling airway inflammation in acute exacerbation of chronic bronchitis. Methods : We studied 40 patients, all of whom had an acute exacerbation of chronic bronchitis. The patients were treated with two different antibiotics, moxifloxacin and clarithromycin, in a double-blind manner for 7 days. Sputum samples were induced and collected before and after antibiotic therapy. We measured the sputum concentration of MMP-1,-9, TIMP-1, IL-8 and secretory leukocyte proteinase inhibitor (SLPI) in sputum supernatants by ELISA method. Results : There was no difference after antibiotic treatment in the sputum concentrations of MMP-1,-9, TIMP-1, IL-8 and SLPI between the patients treated with moxifloxacin and those treated with clarithromycin. But the sputum concentrations of TIMP-1, and SLPI, and the TIMP-1/MMP-1 ratio were significantly reduced by the antibiotic therapy. There were significant positive correlations between sputum TIMP-1 levels and IL-8 levels (p<0.01, r=0.751), and between the sputum TIMP-1/MMP-1 ratio and IL-8 levels (p<0.01, r=0.752). The sputum SLPI levels were significantly elevated by antibiotic treatment and were negatively correlated with sputum TIMP-1 levels (p<0.01, r=-0.496) and TIMP-1/MMP-1 levels (p<0.01, r=-0.456). Conclusion : The study shows that the worsening of airway inflammation in acute exacerbation of chronic bronchitis is associated with an imbalance between the concentrations/levels of TIMP-1 and MMPs. Antibiotic treatment can prevent progression of airway narrowing in acute exacerbation of chronic bronchitis by modulation of the protease and anti-protease imbalance.

Fitness of Adjustable Dental Impression Trays on the Caucasian and African American (백인과 흑인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Park, Yong-Suck;Kim, Yu-Lee;Oh, Sang-Cheon;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.185-192
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Caucasian and African American. Material and methods: The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. Sixty Caucasian (male:30, female:30) and sixty African American (male:30, female:30) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. Results: 1. Uniform impression material width was achieved by controling the width of the tray using stops and beveled guides. 2. In the maxillary tray on the Caucasian, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 13.0 mm. 3. In the maxillary tray on the African American, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 12.0 mm, posterior palatal part 11.0 mm and the labial frenum width was 11.0 mm. 4. In the maxillary tray on the African American, the impression material width of posterior border (0.8 mm) was measured to be small. 5. In the mandibular tray on the Caucasian, the impression material width was measured (2.7-6.7 mm) and posterior border width (2.1 mm) was measured small. The impression material length was measured (2.8-6.7 mm). 6. In the mandibular tray on the African American, the impression material width was measured to be rather great showing width of the labial frenum 9.2 mm and the width of posterior border was measured too small (0.3 mm). Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Caucasian and African American, we can take more easy and accurate dental impressions.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.