• Title/Summary/Keyword: 블로우다운

Search Result 9, Processing Time 0.019 seconds

A Study on the Performance Characteristics of the Hybrid Rocket with Blowdown Oxidizer Feeding System (블로우다운 산화제 공급방식을 적용한 하이브리드 추진 시스템의 성능특성에 관한 연구)

  • Yoon, Chang-Jin;Kim, Jin-Kon;Moon, Hee-Jang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.248-251
    • /
    • 2007
  • The blowdown oxidizer feeding system is effective in the respect of higher reliability by the small number of parts and the absence of additional pressurization tanks, but it also has the unfavorable disadvantage such as thrust variation during the operation. Thus, in order to understand the these performance characteristics inherent in the Hybrid Rocket Motor (HRM) with blowdown oxidizer feeding system, this study proposed the integrated mathematical model to describe physical phenomena in the following parts: the oxidizer tank, combustion chamber, fuel grain, nozzle and injector.

  • PDF

A Study on Modeling of the Pneumatic Part in a Gas Blow-Down System Including Pressure Regulator and Pipe-Line Characteristics (압력조절밸브와 배관 특성을 포함한 유도무기용 기체 블로우다운 시스템의 공압부 모델링에 관한 연구)

  • Park, Youngwoo
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.32-39
    • /
    • 2017
  • In this study, a mathematical model of the pneumatic part in a gas blow-down system is proposed. The mathematical model consists of four major parts: pressure vessel, reservoir, pressure regulator and pipe-line. To ensure accuracy in long-time simulations, heat transfer between gas and pressure vessel is considered. The model is validated by comparing simulation results with experimental data. Experiments are conducted on the ground, where free convection can be assumed. Simulation results indicate the proposed model can accurately describe behavior of a gas blow-down system. Therefore, it may be used for design and analysis of similar systems with a slight modification.

빙축열, 고효율조명, 보일러 스케일방지시설까지 건물 곳곳에 ESCO 시설투자

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.15
    • /
    • pp.22-25
    • /
    • 2002
  • 터미널과 상가로 구성된 서울고속버스터미널은 지난해 건물 냉방을 위한 빙축열시스템과 보일러 스케일방지를 위한 자동 블로우다운 시스템 설치공사를 ESCO사업을 통해 실시했다. 재작년에는 ESCO 고효율조명 교체사업을 마쳤다. 준공이후 설비개체를 하지 않아 노후된 시설이 많았던 터라 이곳 관계자들은 ESCO사업을 통해 에너지비용을 줄이고 훨씬 쾌적한 내부환경을 건물 이용자들에게 제공해줄 수 있게 된 결과에 매우 만족해했다.

  • PDF

기술현황분석 - 원전 압력방출장치의 용량인증기관 현황

  • Son, Sang-Ho
    • 기계와재료
    • /
    • v.26 no.1
    • /
    • pp.50-62
    • /
    • 2014
  • 원전발전소에 납품되는 원전용 안전밸브의 성능은 ASME나 KEPIC와 같은 기술기준코드에 따라 설정압력, 블로우다운(blowdown), 풀리프트(Full lift), 누설(leakage), 방출용량(discharge flow rate)등과 같은 특성인자로 평가된다. 그 중에서도 방출용량은 ASME SEC III NB 7000 코드에 따라 ASME 용량인증이 요구되지만, 아직 국내에는 국제적으로 공인되니 압력방출장치 용량시험기관이 부재하여 외화유출 및 국내 PRD 기술개발에 많은 어려움이 있어왔으며, 이에 따라 원전 PRD 인증기관 개발을 통하여 세계적인 인프라 구축의 필요성이 부각되고 있다. PRD 인증기관 구축은 국내 원전 핵심기자재의 고급기술 국산화에 이바지 할 수 있고, PRD 성능 및 용량시험지원을 통하여 국내 밸브기술 경쟁력 확보하는 데 기여할 것으로 기대된다.

  • PDF

추력기를 이용한 우주비행체 자세제어설계

  • Sun, Byung-Chan;Park, Yong-Kyu
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.186-195
    • /
    • 2005
  • This paper deals with attitude control design for a thruster system which is mainly used as a control system of space vehicles. Attitude controllers are designed based on a simple blowing-down thruster system structure. In order to consider severe time-delay effects of the thruster system during controller design, the control design problem is defined based on the corresponding limit cycle analysis. Optimal roll controllers and optimal pitch/yaw controllers are resulted from co-evolutionary optimum design processes for each flight phase. The control performances are verified by computer simulations.

  • PDF

EFFECTS OF AN ORIFICE-TYPE FLOW RESTRICTOR ON THE TRANSIENT THERMAL-HYDRAULIC RESPONSE OF THE SECONDARY SIDE OF A PWR STEAM GENERATOR TO A MAIN STEAM LINE BREAK (가압경수로 주증기관 파단시 증기발생기 2차측 과도 열수력 응답에 미치는 오리피스형 유량제한기의 영향)

  • Jo, J.C.;Min, B.K.
    • Journal of computational fluids engineering
    • /
    • v.20 no.3
    • /
    • pp.87-93
    • /
    • 2015
  • In this study, a numerical analysis was performed to simulate the thermal-hydraulic response of the secondary side of a steam generator(SG) model equipped with an orifice-type SG outlet flow restrictor to a main steam line break(MSLB) at a pressurized water reactor(PWR) plant. The SG analysis model includes the SG upper steam space and the part of the main steam pipe between the SG outlet and the broken pipe end. By comparing the numerical calculation results for the present SG model to those obtained for a simple SG model having no flow restrictor, the effects of the flow restrictor on the thermal-hydraulic response of SG to the MSLB were investigated.

Modeling and Simulation of the Pneumatic Part in a Cold Gas Blow-Down Type Hydraulic Actuation System for a Missile (상온기체 블로우다운 방식을 사용한 유도무기용 유압식 구동장치의 공압부에 대한 모델링 및 시뮬레이션)

  • Park, Hee Seung
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 2016
  • A cold gas blow-down hydraulic actuation system is widely used in missiles that require an actuation system with a fast response time under a limited space with a short operating time and large loads on the actuators. The system consists of a pneumatic part that supplies the regulated high-pressure gas to a reservoir, and a hydraulic part that supplies pressurized hydraulic oil to the actuators by the pressurized gas in the reservoir. This paper proposes a mathematical model to analyze and simulate the pneumatic part of an actuation system that supplies the operating power to the actuators. The mathematical model is based on the ideal gas equation and also considers the models for heat transfer. The model is applied to the pressure vessel and the gas part of the reservoir, and the model for the pneumatic part is established by connecting the two models for the parts. The model is validated through a comparison of the simulation results with the experimental results. The comparison shows that the suggested model could be useful in the design of the pneumatic part of a cold gas blow-down type hydraulic actuation system.

The Performance Estimation of Pressure-Type Rapid Automatic Filter (압력식 급속 자동 여과장치의 여과성능 평가)

  • Kim, Deok-Jin;Ryu, Hea-Seong;Shin, Sang-Yoon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.607-612
    • /
    • 2006
  • A pressure-type rapid automatic filter of 2000mm diameter and 170 ton/h filtering capacity was fabricated. In case of no external impurity inflow, the turbidity removal efficiency on raw water was experimented and the numbers of impurities of each sizes were analyzed by particle counter. As the result of circulated filtering, the raw water of 40 NTU was filtered to 0.44 NTU and the numbers of impurities above $1{\mu}m$ were removed by approximately 95%. With the filtering efficiency experimented and the mathematical method, the turbidity change of circulation water were calculated according to the inflow rate of external impurity and water treatment method of blow-down or filtering. The cost of blow-down water was calculated from above results. And simple payback period for this filter is calculated as about one year. Nowadays, as the cost of water is continuously increasing and environment regulations will be more strict, the water quality control using this filter will be expected to satisfy the user requirement.

  • PDF