Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

Criminal Law Issues in Epidemiological Investigations Under the INFECTIOUS DISEASE CONTROL AND PREVENTION ACT (감염병의 예방 및 관리에 관한 법률상 역학조사와 관련된 형사법적 쟁점)

  • Jang, Junhyuk
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.3
    • /
    • pp.3-44
    • /
    • 2022
  • As a result of a close review focusing on the case of obstruction of epidemiological investigation by a religious group A in Daegu, which was a problem when the pandemic of Covid-19 infection began in Korea around February 2, 2020, when an epidemiological investigator requested a specific group to submit a list, While there have been cases where an act of not responding or submitting an edited omission list was sentenced to the effect that the act did not fall under an epidemiological investigation, in the case of non-submission of the visitor list for the B Center, even though a 'list of visitors' was requested. Regarding the fact of refusal without a justifiable reason, 'providing a list of persons entering the building is a key factual act that forms a link between epidemiological investigations accompanying an epidemiological investigation, and refusing to do so is also an act of refusal and obstruction of an epidemiological investigation. There are cases where it is possible to demand criminal punishment. Regardless of whether the request for submission of the membership list falls under the epidemiological investigation, there are cases in which the someones' actions correspond to the refusal or obstruction of the epidemiological investigation. A lower court ruling that if an epidemiological investigation is rejected or obstructed as a result of interfering with factual acts accompanying an epidemiological investigation, comprehensively considering whether or not the list has been diverted for purposes other than epidemiological investigation, the logic is persuasive. Epidemiological investigations such as surveys and human specimen collection and testing are conducted for each infectious disease patient or contact confirmed as a result of the epidemiological investigation, but epidemiological investigations conducted on individual individuals cannot exist independently of each other, and the This is because the process of identification and tracking is essential to an epidemiological investigation, and if someone intentionally interferes with or rejects the process of confirming this link, it will result in direct, realistic, and widespread interference with the epidemiological investigation. In this article, ① there are differences between an epidemiological investigation and a request for information provision under the Infectious Disease Control and Prevention Act, but there are areas that fall under the epidemiological investigation even in the case of a request for information, ② Considering the medical characteristics of COVID-19 and the continuity of the epidemiological investigation, the epidemiological investigator the fact that the act of requesting a list may fall under the epidemiological investigation, ③ that the offense of obstructing the epidemiological investigation in certain cases may constitute 'obstruction of Performance of Official Duties by Fraudulent Means', and ④ rejecting the request for information provision under the Infectious Disease Control and Prevention Act from September 29, 2020 In this case, it is intended to be helpful in the application of the Infectious Disease control and Prevention Act and the practical operation of epidemiological investigations in the future by pointing out the fact that a new punishment regulation of imprisonment or fine is being implemented.

Arthroscopic Full-Thickness Rotator Cuff Repair in Elderly Patients (고령 환자의 관절경적 회전근 개 봉합술의 결과)

  • Cheon, Sang Jin;Lee, Dong Ho;Park, Yong Geon;Son, Seung Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2020
  • Purpose: To examine the clinical and structural outcomes of an at least two-year follow-up of arthroscopic full-thickness rotator cuff repairs with a single-row or suture-bridge technique in patients more than 65 years of age. Materials and Methods: Patients diagnosed with a full-thickness rotator cuff tear who were more than 65 years of age, underwent arthroscopic rotator cuff repair after at least six months of conservative treatment, agreed to take a follow-up magnetic resonance imaging (MRI) six months postoperatively, and visited outpatient for at least two years were enrolled in this study. Clinical evaluations were done using The University of California Los Angeles score, Constant Shoulder Score, and visual analogue scale evaluated two years after the surgery. The structural integrity was analyzed using follow-up MRI. During surgery, a suture-bridge technique was used if the rotator cuff tendon could cover half of the footprint under constant tension. Otherwise, single-row repair was performed. Results: The samples were 158 cases, consisting of 93 single-repairs and 65 suture-bridge repairs. A preoperative comparison of the age distribution, fatty degeneration of supraspinatus and infraspinatus muscle, medial retraction of torn cuff tendon, and tear size between the two groups were not significant. The clinical scores were improved significantly in all cases. The distribution of the structural integrity by Sugaya classification were 49 cases in type 1 (31.0%), 62 cases in type 2 (39.2%), 30 cases in type 3 (19.0%), 11 cases in type 4 (7.0%), and six cases in type 5 (3.8%). The re-tear rate of the single-row group was 9.7% (nine out of 93 cases) and 12.3% (eight out of 65 cases) for the suture-bridge group. Conclusion: Satisfactory clinical and radiological outcomes were achieved after arthroscopic full-thickness rotator cuff repair in patients more than 65 years of age. Both single-row and suture-bridge techniques would be beneficial for the elderly.

The Role of Inhaled Corticosteroid in the Management of Chronic Cough (만성 기침에서 스테로이드 흡입제의 역할)

  • Lee, Kyung-Hun;Jang, Seung Hun;Lee, Jung-Hwa;Eom, Kwang-Seok;Bahn, Joon-Woo;Kim, Dong-Gyu;Shin, Tae Rim;Park, Sang Myon;Lee, Myung-Gu;Kim, Chul-Hong;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.2
    • /
    • pp.221-227
    • /
    • 2006
  • Background : Cough may be a consequence of bronchial hyperresponsiveness or inflammation. Empirical treatment is important in this context because it difficult to verify the obvious cause of cough using laboratory tests, Corticosteroid has a nonspecific anti-inflammatory effect, and can be used for cough management. However, its response rate has not yet been fully elucidated. This study investigated the short- term effects of inhaled corticosteroid on chronic cough Methods : Patients with chronic cough with a normal chest radiograph and a pulmonary function test were enrolled. Cases with a prior respiratory infection within 8 weeks, a history of bronchial asthma, objective wheezing on examination, subjective symptoms of gastroesophageal reflux or taking an ACE inhibitor were excluded. On the first visit, a methacholine bronchial provocation test, spontaneous sputum eosinophil count performed twice and a paranasal sinus radiograph were checked, and the patients were treated with budesonide turbuhaler $800{\mu}g/day$ for ten days. The primary outcome measure was a decrease in the cough score after treatment. Results : Sixty nine chronic coughers were finally analyzed. The final diagnoses by the routine tests were as follows: bronchial asthma 13.0%, eosinophilic bronchitis 18.8%, paranasal sinusitis 23.2% and non-diagnostic cases 53.6%. The following responses to the inhaled corticosteroid were observed: definite responders, 76.8%, possible responders, 2.9% and non-responders, 20.3%. The response rate was not affected by the final diagnosis even in the non-diagnostic cases. There were minimal adverse drug related effects during the empirical treatment. Conclusion : Routine objective tests such as methacholine provocation, sputum eosinophil count and simple radiographs were notare not suitable for diagnosing chronic cough Therefore, empirical treatment is important. Short term inhaled corticosteroid is effective and can guide a further treatment plan for chronic cough.

Diagnostic Performance of Routine Objective Tests and Cost-Effective Approach for Chronic Cough (만성 기침의 진단 성적과 경제적 접근 모델)

  • Jeon, Gang;Jang, Seung Hun;Song, Hae Geun;Ha, Jun-Wook;Eom, Kwang-Seok;Bahn, Joon-Woo;Kim, Dong-Gyu;Shin, Tae Rim;Park, Sang Myon;Park, Yong Bum;Kim, Chul-Hong;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.6
    • /
    • pp.535-542
    • /
    • 2004
  • Background : Despite the clinical clues of bronchial asthma, some chronic coughers fail to be diagnosed due to negative test results. This study was aimed at evaluating the diagnostic performance of routine objective tests and identifying a cost-effective approach for asthmatics with a chronic cough. Methods : Patients with a chronic cough of more than 3 weeks duration, and showing normal chest radiograph and spirometry were enrolled. On the first visit, objective tests, composed of serum total IgE, peripheral blood eosinophil count, spontaneous sputum eosinophil count, methacholine bronchial provocation test (MBPT) and paranasal sinus radiograph, were performed, with the simultaneous administration of oral prednisolone (0.5mg/kg) for one week. The final diagnoses were made on the basis of the test results, and the patients grouped according to their steroid responsiveness. The role of the etiologic diagnosis tests was evaluated, and the medical costs of the final management plan simulated with respect to three assumed models. Results : Sixty chronic coughers were finally analyzed. The final diagnoses were as follows: bronchial asthma 21.7%, eosinophilic bronchitis 6.7%, paranasal sinusitis 18.3%, presumptive allergy 8.3% and non-diagnostic case 45.0%. Ninety percent were steroid responder. With the bronchial asthma cases, the positive rate of MBPT was 38.5%, with sputum eosinophil count in 84.6%, serum total IgE in 38.5%, and a peripheral blood eosinophil count rate of 30.8%. When the test results and steroid responsiveness data were applied to the 3 models, the chest radiograph, spirometry, sputum eosinophil count and paranasal sinus radiograph test results, and simultaneous short term steroid treatment seemed to have acceptable diagnostic performances, which could be used as a further guide to cost-effective planning. Conclusion : Objective tests, composed of chest radiograph, spirometry, paranasal sinus radiograph and sputum eosinophil count, with simultaneous short term steroid treatment, are suggested as cost-effective approaches for asthmatics with a chronic cough.

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.

Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.