• Title/Summary/Keyword: 불요 방사

Search Result 122, Processing Time 0.027 seconds

A Simulation Investigation on the Spurious Emission Reduction of the Automotive DC-DC Converter (자동차용 DC-DC 컨버터의 전자파 방사 감소 방법에 대한 시뮬레이션 연구)

  • Chae, Gyoo-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.47-52
    • /
    • 2020
  • In this study, a simulation investigation was conducted on the method of reducing switching noise and spurious emission among design methods for step-down DC-DC converter modules for automotive. A typical 4-layer converter circuit using a PMIC(Power Management Integrated Circuit) chip was presented, and the simulation results of conductive emissions at two input terminals (+, -) and the point between the input filter and the PMIC was performed in the 1.0~5.0MHz band and the 100MHz band. The results for the conducted and radiated emissions in the HF(3~30MHz) and VHF(30-300MHz) bands were presented. It showed an improvement of about 10dB over the bands by routing the output terminal placed on the 3 or 4-layer in the opposite direction to the input terminal. The result of this study is expected to be useful in the design of the DC-DC converter modules in the future because it gives a better improvement compared to the existing methods.

A study on technical standard of surge tests (Surge 시험 기술 기준에 대한 고찰)

  • 양윤석;위규진
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.2
    • /
    • pp.55-72
    • /
    • 1993
  • 기술의 발달과 정보화 사회로의 이행은 각종 전기, 전자 기기 사용의 양적, 질적 증가를 가져 왔으며 이에 따른 불요 전자파는 전기, 전자 기기 상호간의 장해, 인체에의 유해 등 기술적, 사회적 문제로 나타나 고 있다. 따라서, 전자파 환경을 보호하기 위하여 전자파 장해 검정 제도가 국, 내외 적으로 시행되고 있으며 또한 열악한 전자파 환경에서 정상적인 동작을 보장하기 위한 전자파 내성이 요구되고 있다. 이러한 전자파 내성을 국제 전기 표준 위원회(IEC)에서는 그 원인에 따라 ESD 내성(정전기 방전), 방사 내성, EFT 내성(급격한 과도 현상), Surge 내성, 전도 내성 등으로 분류하고 있으며 원인별 시험 기술기준도 작성되고 있다. (IEC 801 시리즈)

  • PDF

Modeling and Application of 1D DGS Using Transmission Line Theory (1D DGS에 대한 전송이론적 모델링 및 응용)

  • 신윤미;이지면;이범선
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.152-156
    • /
    • 2001
  • 본 논문에서는 단일 DGS의 전송특성을 ABCD 파라미터로 모델링하여 연속한 N개의 DGS 분석 및 설계를 용이 하게 하였다. 모델링된 식의 검증을 위해 연속된 N개의 주기적 DGS에서 전송특성을 이론, 회로 시뮬레이션, EM 시뮬레이션을 비교하였다. 또한 응용 예로서, 능동안테나의 불요 고조파가 방사하는 것을 저지하기 위한 DGS를 설계 및 시뮬레이션하여 제시된 방법론의 타당성을 검증하였다.

  • PDF

First flush modeling of the radial type surface runoff and a placement strategy for stormwater inlets to improve the effectiveness of the first flush treatment in a small impervious catchment (방사형 강우 유출의 초기세척 모의 및 소규모 불투수 배수구역에서의 초기우수 처리효과 상승을 위한 집수시설 배치 방안)

  • Kang, Joo-Hyon;Lee, Dong Hoon;Kim, Jin Hwi
    • Journal of Wetlands Research
    • /
    • v.19 no.4
    • /
    • pp.375-382
    • /
    • 2017
  • In this study, general characteristics of dynamic behavior of stormwater runoff from a small impervious catchment was investigated from a series of simulations for a radial type surface runoff. Based on the simulation results, a better placement strategy for stormwater inlets to improve performance of a structural best management practice (BMP) was suggested. The degree of pollutant first flush from an ideal radial type impervious catchment was simulated using a 1-D diffusion wave equation coupled with a pollutant transport equation. The results showed that the first flush of the chemical oxygen demand was the strongest when the catchment length ranged 30-50m at a bed slope of 0.02. This result suggested that a required degree of the first flush can be intentionally obtained by just changing the locations and numbers of stormwater inlets, and thereby adjusting the catchment length. Particularly, the overall performance of a structural BMP in reducing pollutant load can be improved by placing the stormwater inlets at locations for obtaining a required first flush strength.

Determination of Therapeutic Dose of I-131 for First High Dose Radioiodine Therapy in Patients with Differentiated Thyroid Cancer: Comparison of Usefulness between Pathological Staging, Serum Thyroglobulin Level and Finding of I-123 Whole Body Scan (분화 갑상선암 수술 후 최초 고용량 방사성옥소 치료시 투여용량 결정: 병리적 병기, 혈청 갑상선글로불린치와 I-123 전신 스캔의 유용성 비교)

  • Jeong, Hwan-Jeong;Lim, Seok-Tae;Youn, Hyun-Jo;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.301-306
    • /
    • 2008
  • Purpose: Recently, a number of patients needed total thyroidectomy and high dose radioiodine therapy (HD-RAI) get increased more. The aim of this study is to evaluate whether pathological staging (PS) and serum thyroglobulin (sTG) level could replace the diagnostic I-123 scan for the determination of therapeutic dose of HD-RAI in patients with differentiated thyroid cancer. Materials and Methods: Fifty eight patients (M:F=13;45, age $44.5{\pm}11.5\;yrs$) who underwent total thyroidectomy and central or regional lymph node dissection due to differentiated thyroid cancer were enrolled. Diagnostic scan of I-123 and sTG assay were also performed on off state of thyroid hormone. The therapeutic doses of I-131 (TD) were determined by the extent of uptakes on diagnostic I-123 scan as a gold standard. PS was graded by the criteria recommended in 6th edition of AJCC cancer staging manual except consideration of age. For comparison of the determination of therapeutic doses, PS and sTG were compared with the results of I-123 scan. Results: All patients were underwent HD-RAI. Among them, five patients (8.6%) were treated with 100 mCi of I-131, fourty three (74.1%) with 150 mCi, six (10.3%) with 180 mCi, three (5.2%) with 200 mCi, and one (1.7%) with 250 mCi, respectively. On the assessment of PS, average TDs were $154{\pm}25\;mCi$ in stage I (n=9), $175{\pm}50\;mCi$ in stage II (n=4), $149{\pm}21\;mCi$ in stage III (n=38), and $161{\pm}20\;mCi$ in stage IV (n=7). The statistical significance was not shown between PS and TD (p=0.169). Among fifty two patients who had available sTG, 25 patients (48.1%) having below 2 ng/mL of sTG were treated with $149{\pm}26\;mCi$ of I-131, 9 patients (17.3%) having $2{\leq}\;sTG\;<5\;ng/mL$ with $156{\pm}17\;mCi$, 5 patients (9.6%) having $5{\leq}\;sTG\;<10\;ng/mL$ with $156{\pm}13\;mCi$, 7 patients (13.5%) having $10{\leq}sTG\;<50\;ng/mL$ with $147{\pm}24\;mCi$, and 6 patients (11.5%) having above 50 ng/mL with $175{\pm}42\;mCi$. The statistical significance between sTG level and TD (p=0.252) was not shown. Conclusion: In conclusion, PS and sTG could not replace the determination of TD using I-123 scan for first HD-RAI in patients with differentiated thyroid cancer.

Effect of oxyfluorination on activated electrospun carbon nanofibers for $CO_2$ storage (함산소불소화 효과에 의한 전기방사 활성탄소나노섬유의 $CO_2$ 저장)

  • Bai, Byong Chol;Kim, Jong Gu;Im, Ji Sun;Lee, Young-Seak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.219.2-219.2
    • /
    • 2011
  • The oxyfluorination effects of electrospun carbon nanofibers (OFACFs) were investigated for $CO_2$ storage. Carbon nanofibers were prepared form poly acrylonitrile / N,N-dimethylformamide solution through electrospinning method and heat treatment. Chemical activation of carbon nanofibers were carried out in order to improve the pore structure. And the surface modification of activated carbon nanofibers was conducted by oxyfluorination to improve the $CO_2$ storage on effect of introduced functional groups. The samples were labeled CF (electrospun carbon nanofiber), ACF (activated carbon nanofibers), OFACF-1 ($F_2:O_2$ = 3:7), OFACF-2 ($F_2:O_2$ = 5:5) and OFACF-3 ($F_2:O_2$ = 7:3). The functional group of OFACFs was investigated by x-ray photoelectron spectroscopy analysis. The specific surface area, pore volume and pore size of OFACFs were calculated and pore shape was estimated by the BET equation. Through the adsorption isotherm, the specific surface area and pore volume significantly decreased by oxyfluorination.

  • PDF

연구로 1호 TRIGA Mark - II - 33년 운영과정과 폐로계획

  • 서두환
    • Nuclear industry
    • /
    • v.15 no.11 s.153
    • /
    • pp.48-52
    • /
    • 1995
  • 연구로 1호는 우리나라 최초의 원자로로서, 62년 3월 19일 최초 임계에 도달하여, 우리나라에서 처음으로 `제3의 불`을 점화시켰다. 그후 33년 동안 연구로 1호는 그 역할을 최대한 수행하였다. 이제는 노후된데다가 새 연구로인 $\ulcorner$하나로$\lrcorner$의 완공에 따라, 금년말경에는 운전을 정지하여 방사성물질을 제거한 후, 2000년경에 기념전시관으로 이용할 계획으로 있다. 연구로 1호의 건설$\cdot$운영$\cdot$이용 및 그 폐로계획에 대하여, 33년간의 그 흥성과 종결을 연보형식으로 그 발자취를 되새겨보면서 살펴본다.

  • PDF

Characteristics of Resonance Suppression of PBS using EBG (EBG 구조를 이용한 전력공급/접지판의 RF 잡음저감 특성)

  • Sin, Eun-Cheol;Kim, Hyeong-Seok;Gang, Seung-Taek
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.504-506
    • /
    • 2008
  • 전기전자 장치 내부의 PCB에 존재하는 전력공급/접지판은 RF 공진잡음을 발생시켜 디지틀 신호 품질 저하 및 불요방사의 문제를 일으킨다. 본 논문에서는, 전력공급/접지판의 RF 잡음을 제거하기 위한 방법으로 Mush-room EBG 구조를 사용할 때 이 구조가 가지는 전자기 및 전기적 특성을 모드해석법과 회로이론의 하이브리드화를 통해 예측을 수행한다. 예측을 통해 잡음을 억제할 수 있는 유용한 정보를 얻는다.

  • PDF

A Method for Estimating Mean Residence Time of Water using Soil Moisture at a Hillslope on the Forested Catchment (토양수분을 이용한 산림사면에서의 물 평균체류시간 추정방법)

  • Kwak, Yong-Seok;Jin, Sung-Won;Kim, Sang-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.308-313
    • /
    • 2009
  • 유역에서 물의 평균체류시간은 강우에 의해 토양에 강우 등으로 인해 수분이 침투하여 유출되기까지 소요되는 평균 시간이며, 침식, 식생분포, 유출기작 등을 지배하는 수문학적 과정을 이해하는데 중요한 요소이다. 물의 평균체류시간을 산정하는 대표적인 방법인 방사성 동위원소에 의한 추적자법은 계산과정이 복잡하고 많은 비용이 들면서도 간접적인 방법임으로, 본 연구에서는 토양수분의 거동을 관측해 산지사면에서 물의 평균체류시간을 산정하는 보다 직접적인 방법을 고안하였다. 토양수분의 측정을 위해 광릉 국립수목원에 위치한 산림 소유역에 토양 수분 측정장비인 TDR을 설치하고 1년 동안 2시간 간격으로 깊이별 측정을 수행하였다. 토양수분을 이용해 산정된 물의 체류시간은 대상유역의 불투수 지하면에 가까워질수록 상승하는 경향을 보였고 강우가 집중된 여름에 가장 짧은 것으로 나타났다. 실험에서 얻어진 평균체류시간은 기존의 화학적 방법을 통해 산정된 값과 유사한 경향을 보였는데 이러한 결과들은 토양수분의 측정과 분석을 통한 방법이 방사성 동위원소를 이용한 방법보다 더욱 효율성 있는 측정을 할 수 있다는 것을 나타낸다.

  • PDF