• Title/Summary/Keyword: 불안정성 골절

Search Result 44, Processing Time 0.021 seconds

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Review in Remplissage on Anterior Shoulder Instability with Huge Hill-Sachs Lesion (전방 견관절 불안정성의 Hill-Sachs 병변의 치료에서 Remplissage의 Review)

  • Ko, Sang-Hun;Lee, Chae-Chil;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.134-139
    • /
    • 2011
  • Purpose: We wanted to review the arthroscopic Remplissage technique and introduce our experiences with it for treating recurrent shoulder instability with a large Hill-Sachs lesion. Materials and Methods: The arthroscopic Remplissage technique with Bankart repair is performed in patients with no osteoarthritis, no fracture around the shoulder, a history of recurrence more than 10 times, a large Hill-Sachs lesion more than 30 to 40% of the humeral articular surface and glenoid bone loss less than 20%. Results and Conclusion: For recurrent shoulder instability with a large Hill-Sachs lesion, the Remplissage technique resulted in a good outcome for the shoulder stability, and good clinical and functional results.

The Difference between Short and Long Intramedullary Nailing as the Treatment for Unstable Intertrochanteric Femoral Fracture (AO/OTA 31-A2) in Elderly Patients (고령환자에서 발생한 불안정성 대퇴골 전자간부 골절(AO/OTA 31-A2)의 치료 시 골수강내 금속정의 길이에 따른 추시 결과)

  • Shin, Won Chul;Lee, Eun Sung;Suh, Kuen Tak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.25-32
    • /
    • 2017
  • Purpose: The purpose of this study was to analyze the radiological and clinical outcomes in elderly patients with unstable intertrochanteric femur fractures in accordance with the length of intramedullary nail. Materials and Methods: Between August 2009 and December 2014, a total of 139 patients-older than 65 years of age with AO/OTA classification of 31-A2 unstable intertrochanteric femur fracture-who has been followed-up for at least 1 year after the treatment with internal fixation by using an intramedullary nail were enrolled for this retrospective control study. The subjects were classified into two groups according to the length of intramedullary nail: 106 patients in the short group (group I) and 33 patients in the long group (group II). For radiological assessments, the reduction state, time to union, and implant related complications were examined. The clinical outcomes were assessed by preoperative hemoglobin, operating time, intraoperative bleeding amount, blood transfusion rate, hospitalization period, and Charnley hip pain scoring system at the final follow-up. Results: The postoperative radiographs showed good or acceptable reduction in all cases. The mean time of radiologic bone union was 4.8 months, and there was no difference between the two groups. With respect to surgical time, the group II was found to take longer (57.87 minutes) than the group I (45.65 minutes) (p=0.003). The bleeding amount during surgery of the group II was greater (288.78 ml) than that of the group I (209.90 ml) (p=0.046). The clinical results at the final follow-up were found to be satisfactory in both groups. Conclusion: In cases of good reduction of the fracture from the treatment of unstable intertrochanteric femur fracture accompanying the posteromedial fragment in elderly patients, both groups-long and short intramedullary nails-showed satisfactory radiological and clinical outcomes.

Complications after Trauma Around the Elbow Joint (주관절 주위 외상후 합병증)

  • Jeon, In-Ho;Kim, Ju-Eun;Kim, Poong-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.264-270
    • /
    • 2009
  • Purpose: The elbow joint is one of the most stable joints. Dislocation and fracture can occur in elbow joint most commonly next to shoulder joint. Various injuries can occur according to generated mechanism, age of patient and impact. Despite proper treatment, various complications can occur. Materials and Methods: We describe etiology and treatment of these complications after elbow trauma such as stiffness, instability and heterotopic ossification. Results and Conclusion: Malunion, nonunion and traumatic arthritis are addressed as a possible complication after fracture around elbow joint.

Clinical Application of Radial Head Prosthesis (요골두 치환술의 임상적 적용)

  • Moon, Jun-Gyu
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.140-145
    • /
    • 2011
  • Purpose: Installing a radial head prosthesis has developed into a reliable procedure to replace the native radial head for treating unreconstructible radial head fracture when this is associated with an unstable elbow or forearm. A variety of implants have been developed and these are now commercially available. This article reviews the literature related to the indications, the available implants and the surgical techniques of radial head replacement arthroplasty. Materials and Methods: The main indication for a metallic radial head prosthesis is a comminuted fracture that is not amenable to reconstruction, and particularly if it is associated with complex elbow injuries. Excision of the radial head should be avoided in the presence of combined injured ligaments or interosseous membrane injury. Three different implants are available in Korea, including the bipolar, press fit monopolar and loose fit monopolar radial head prostheses. A primary technical goal of radial head arthroplasty is the insertion of an implant that closely replicates the native radial head. The major pitfall when using a metallic radial head prosthesis is the insertion of a longer implant, which results in overstuffing of the radiocapitellar joint. Results and Conclusion: Satisfactory clinical results can be anticipated when a radial head prosthesis is used for the correct indications and when a systemic approach is undertaken to ensure proper sizing. For the future studies, we need data regarding the long term outcomes and comparison of the various types of prostheses.

The Operative Treatment of Scapular Glenoid Fracture (견갑골 관절와 골절의 수술적 치료)

  • Kang, Ho-Jung;Jung, Sung-Hoon;Jung, Min;Hahn, Soo-Bong;Kim, Sung-Jae;Kim, Jong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.212-219
    • /
    • 2007
  • Purpose: To determine the causes of the surgical treatment results in glenoid fracture by a retrospective analysis. Materials and methods: From March 1999 to February 2004, 9 patients who underwent an open reduction due to a glenoid fracture were reviewed. The modified Ideberg classification was used. There were 1, 3, 2, 1 and 2 cases of modified Ideberg type I, II, III, V, and VI, respectively. The internal fixators were a reconstruction plate, a small plate, a one-third tubular plate, a small screw, and a cannulated screw in 6, 1, 3, 3 and 1 case, respectively. The constant score and Adam's functional assessment method were used to evaluate the postoperative shoulder function. Results: The average time for fracture union was 7 weeks. The functional assessment was excellent in 4 cases, good in 3 cases, and fair in 2 cases. There were two complications related to surgery; articular screw encroachment, and inferior glenoid bone resorption without instability. Conclusion: A glenoid fracture with glenohumeral instability or displaced that was treated by open surgery showed good clinical results. Moreover, the more comminuted fracture had a lower functional score.

Customized Model Manufacturing for Patients with Pelvic Fracture using FDM 3D Printer (FDM 방식의 3D 프린터를 이용한 골반 골절 환자의 맞춤형 모델제작)

  • Oh, Wang-Kyun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.370-377
    • /
    • 2014
  • At present trend 3D Printing technology has been using more efficiently than conventional subtractive manufacturing method in various medical fields, in particular this technology superior in saving production time, cost and process than conventional. Especially in orthopedics, an attractive attention has been paid by adopting this technology because of improving operation, operation accuracy, and reducing the patient's pain. Though 3D printing technology has enormous applications still in some hospitals have not been using due to having the problem of technical utilization of hardware, software & chiefly financial availability and etc. In order to solve these problems by reducing the cost and time, we have used CT images in pre-operative planning by directly making the pelvic fracture model with open source DICOM viewer and STL file conversion program, assembly 3D printer of FDM wire additive manufacturing. After having the customized bone model of six patients who underwent unstable pelvic fracture surgery, we have operated our system in orthopedic section of University Hospital through the clinician. Later, we have received better reviews and comments on utilization availability, results, and precision and now our system considered to be useful in surgical planning.

Avulsion of the Tibial Attachment of the Posterior Cruciate Ligament in a 13-year-old child - A Case Report - (13세 소아에서 후방십자인대의 경골 부착 부위의 견열 골절 - 증례보고-)

  • Lee Kwang-Won;Lee Seung-Hun;Kim Ha-Yong;Kim Byung-Sung;Choy Won-Sik
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.61-64
    • /
    • 2002
  • The authors report one case of isolated avulsion fracture of the tibial attachment of the posterior cruciate ligament. A 13 years old boy was admitted for right knee pain and swelling after the soccer injury on his knee. Hemarthrosis and posterior instability were present. Simple roentgenographic examination showed an isolated avulsion fracture of the tibial attachment of the posterior cruciate ligament. Open approach through the popliteal fossa was used and bony fragment was fixed into its bed using pull-out sutures. Postoperatively, a long leg cast was applied for 4 weeks. The patient was followed for 6 months. He returned to his previous activity levels. There was no residual laxity. Isolated avulsion of the posterior cruciate ligament from the tibia before the epiphyseal fusion is very rare in children. We reported one case of our experience and its result.

  • PDF

Treatment of an Occipital Fracture by Esquillectomy (골편적출술을 적용한 후두골 골절 치료)

  • Park, Jin-Uk;Cho, Ki-Rae;Chang, Dong-Woo;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.450-452
    • /
    • 2010
  • A 4-year-old male Yorkshire terrier was referred to us with signs of vomiting and unconsciousness due to a blunt head trauma. Gross examinations detected facial edema, subcutaneous hemorrhage and hypersalivation. A survey radiograph located an occipital fragment which was displaced caudally. A three-dimensional computed tomographic reconstruction demonstrated that the ventral portion of the fragment was attached incompletely. Because of the instability of the fragment, it was decided to perform an esquillectomy. After removing the fragment, the defect was reinforced with a muscular flap originating from the splenius muscle. The patient's condition gradually improved except for a slightly ataxic gait. At 20 months follow-up, there was no evidence of ataxia. The neurological status did not deteriorate before starting surgical intervention, although the patient sustained a skull fracture with severe intracranial hemorrhage. It is likely that the fragment being displaced outwardly played an important role in preventing an increase in intracranial pressure which could have led to neurological deterioration.

Comparison of Three Surgical Method Outcomes for Dorsal Communition Distal Radial Fractures: External Fixation, External Fixation with Allogenous Bone Graft (DBM) and Volar Locking Plate Fixation (배측 분쇄가 있는 원위부 요골 관절내 골절의 3가지 수술적 치료 결과 비교: 외고정 기구 단독, 외고정 기구와 동종골이식 및 수장측 잠김 압박 금속판)

  • Choi, Joon-Cheol;Na, Hwa-Yeop;Lee, Young-Sang;Kim, Woo-Sung;Oh, Kyung-Soo;Song, Woo-Suk;Kim, Se-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose: To evaluate the outcomes of three different surgical approaches in treating a distal radius fracture with dorsal communition. Materials and Methods: From April, 2006 to May, 2009, 49 patients over age of 60years old with unstable dorsal communition distal radius fracture were analyzed. We compared maintainability of reduction by radiological follow-up observations and clinical outcomes using Mayo wrist scores. One-Way ANOVA test was performed to examine the statistical correlation between the methods. Results: All three approaches provided satisfactory post-op reduction results. However, follow-up observations showed significant loss of reduction in the external fixation only group compared to the added bone graft group and the volar anatomical locking plate group (P<0.05). Mayo wrist score was indifferent between the three groups. Conclusion: Treatment of a distal radius fracture with severe dorsal communition using an external fixation only appears to be insufficient in maintaining reduction of a cancellous bone defect.

  • PDF