• Title/Summary/Keyword: 불균일 보상

Search Result 34, Processing Time 0.016 seconds

A research on improving signal to noise ratio for magnetic resonance imaging through increasing filling factor inside surface coil (자기공명 검사시 코일 내 filling factor 증가를 통한 신호대 잡음비의 향상에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5299-5304
    • /
    • 2012
  • MRI signals are significantly reduced by the magnetic field inhomogenity result from human body itself being consisted of various materials like air, fat, muscle, bone and blood vessels. In this study we used silicon which is tissue equivalent to compensate wound body shapes. Objects were eight adults who do not have any special symptoms. Feet were scanned because of their complicated structures and consequently signal reduction occurs a lot. Thirty images were acquired from the middle of arcus pedis longitudinalis including five distal phalanges parallel to the line connecting metatarsal bone and phalanges. SNR data from bones and soft tissues were compared before and after sticking silion between toes and paired t test was performed. It was came out that SNR data from bone and soft tissue were both significantly higher after applying silicon on both T1 and T2 weighted images and it was statistically meaningful having positive corelation. As a result, this study dramatically increases SNR without affecting object by increasing the object volume inside the surface coil.

A Study on Beam Operation of an Airborne AESA Radar with Uniform Search Performance in Whole Scan Area (전 탐색 영역 균일 성능을 갖는 항공기 탑재 능동 위상 배열 레이더의 빔 운용 연구)

  • Ahn, Chang-Soo;Roh, Ji-Eun;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.740-747
    • /
    • 2012
  • An Active Electronically Scanned Array(AESA) radar required necessarily as the Fire Control Radar(FCR) of recent fighters has ununiform detection range with regard to scan angle due to scan loss. Although the compensation method of scan loss in an AESA radar with variable dwell time is investigated, the effectiveness of the method in a fighter FCR with multi-function such as search, track, and missile guidance within limited resources should be considered systematically. In this paper, uniform search performance of an AESA radar using variable dwell time with regard to scan angle is derived. We assumed the search load of 50 % for case without changing dwell time in fixed frame time and showed the fighter FCR requirement for multi-function is not satisfied because the search load for the uniform search performance should be increased by about 100 %. On the other hand, in case of increasing the frame time for the uniform search performance and search load of 50 %, degradation of the search performance is shown by 86.7 % compared with the former. Based on these analyses, the effective beam operation strategy on an airborne AESA radar with uniform search performance in whole scan area is described with consideration of frame time, search load and performance as a whole.

The Effects of Substituted $Co^{+2}$ and $Ti^{+4}$ Cations on Magnetic Properties and Particle Characteristics of Ba-Ferrite Powder for Use in High Density Magnetic Recording (고밀도 자기기록용 Ba-Ferrite 분말의 자기적 물성과 입자특성에 미치는 $Co^{+2}$$Ti^{+4}$의 효과)

  • 홍양기;박상준;정홍식
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.4
    • /
    • pp.275-280
    • /
    • 1995
  • The sites for $Fe^{+3}$ are partly substituted by $Co^{+2}$ and $Ti^{+4}$ cations to control coercivity of Ba-ferrite particles for use in high density magnetic recording. The substituted $Co^{+2}$ cation has very much different effects on magnetic properties and particle characteristics from that $Ti^{+4}$ cation has. The decrease in the coercivity with the $Co^{+2}$ substitution is attributed to the formation of excessive spinel-block(S-block) in pure Ba-ferrite crystal, while saturation magnetization is increased and the distributions of coercivity and particle size become broad. The substitution with the $Ti^{+4}$ decreases the sauration magnetization, but has less effect on a change in coercivity than the $Co^{+2}$. The $Ti^{+4}$ acts as a nucleation agent in amorphous phase of formulated compound, and consequently particle size and aspect ratio are decreased. Furthermore, the enhancement of substitution of the $Co^{+2}$ for the $Fe^{+3}$ sites in rhombohedral-block(R-block) by the $Ti^{+4}$ retards the nucleation of spinel phase of Ba-ferrite, which results in uniform magnetic properties of Ba-ferrite particles. It is suggested that the contents of the cations to be substituted for the $Fe^{+3}$ sites are optimized on the bases of magnetic properties and particle characteristics rather than on the base of electrical charge balance.

  • PDF

Study of the error chsracteristics in a mirror loss measurement system using an exqonential decay metod (지수감쇠 기법을 이용한 반사경 손실측정 시스템의 오차특성 연구)

  • 조민식
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • Error characteristics of a mirror loss measurement system using an exponential decay method were studied, with the two samples having about 200-ppm-loss and 30-ppm-loss, respectively. In order to minimize the decay signal deviation from an exponential curve due to cavity length fluctuation, a data average method was tried. The data average method significantly improved the exponential curve fitting error of the decay signal, so that for a 6 decay signal data average the loss measurement error was reduced by about 2.4 times for the 200-ppm-loss mirror and 1.3 times for the 30-ppm-loss mirror compared with a single shot measurement. Day-to-day mirror loss repeatability error for the two samples was investigated. The repeatability error was measured to be about 5% for the 200-ppm-loss mirror and about 26.4% for the 30-ppm-loss mirror. Low decay signal average effect and high repeatability error in the low loss mirror measurement were explained with non-uniform spatial loss distribution of the sample and contamination from the environment, in addition to the error sources of the mirror loss measurement system itself. The influence of cavity length fluctuation and cavity length measurement error on the mirror loss measurement system performance was theoretically calculated. It confirmed that the requirement for the cavity length parameters was not so strict in the mirror loss measurement system of several ppm resolution. ution.

  • PDF