• Title/Summary/Keyword: 불균등화 반응

Search Result 6, Processing Time 0.021 seconds

Analysis of Oxidation-reduction Equilibria in Aqueous Solution Through Frost Diagram (Frost도를 이용한 수용액의 산화-환원반응 평형 해석)

  • Lee, Man Seung
    • Resources Recycling
    • /
    • v.26 no.4
    • /
    • pp.3-8
    • /
    • 2017
  • Oxidation-reduction reaction is one of the most important reactions occurring in the aqueous phase. Analysis of the equilibria related to these oxidation-reduction reactions is of great value in designing many unit operations in hydrometallurgy, such as leaching, separation and electrochemical reactions. The construction of Frost diagram was discussed in this work. The conditions at which disproportionation and proportionation reactions can occur were explained by analyzing Frost diagram together with Latimer table. The information which can be obtained from Frost diagram was discussed.

Hydrodynamic and Atmospheric Effects on Corrosion of Zinc in Borate Buffer Solution (Borate 완충용액에서 아연의 부식에 대한 대류와 대기의 영향)

  • Chung, Se-Jin;Kim, Youn-Kyoo
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.575-580
    • /
    • 2011
  • It was investigated into the effects on zinc corrosion of the rotation speed of Zn-RDE and the oxygen concentration in borate buffer solution. Zinc corrosion was heavily influenced on the rotation speed of electrode and the oxygen concentration. We have suggested the disproportion reaction following the reversible one electron transfer as the corrosion mechanism of zinc.

A Study on Flow Distribution to Flocculation Basins Using DOE and RSA (실험계획법과 반응표면분석법을 적용한 응집지로의 유량분배에 관한 연구)

  • Kim, Seong-Jae;Kyung, Gyu-Sun;Jeong, Heui-Jung;Kim, Hyeong-Seop;Yang, Sa-Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.918-928
    • /
    • 2013
  • The inequitable flow distribution to flocculation basins is an important problem faced in many water treatment plants. This is caused by the structure of a distribution channel, the height differences of outlet weirs etc. But, a modified approach for the structures has no effectiveness to achieve flow equality. The aim of this study is to reduce the inequality by adopting optimized inlet valve opening (%) of the flocculation basins using DOE (Design of Experiments) and RSA (Response Surface Analysis). The inlet valve openings (%) and inflow distributions (%) of 6 paralleled basins were set as factors (X) and characteristics(Y) respectively. 2 level factorial experiments and RSA were conducted for optimization and regression analysis (Y = f(X) + Const.). Adopting the optimized inlet valve opening (%) at field, standard deviation of flow distribution (%) and effluent turbidity was declined from 3.80% to 0.42% and from 0.29 NTU to 0.03 NTU respectively.

Mechanistic Studies for Electrochemical Oxidation of ${\iota}$-Sparteine (${\iota}$-Sparteine의 전기화학적 산화반응에 대한 메카니즘의 연구)

  • Jin-Hyo Park;Chang-Soo Jin;Sung-Nak Choi;Yoon-Bo Shim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.711-716
    • /
    • 1993
  • The mechanism for electrochemical oxidation of natural alkaloid, ${\iota}$-sparteine (SP) was studied in acetonitrile solvent. The cyclic voltammogram of SP shows two irreversible anodic peaks at +0.75 V and +1.45 V vs. Ag/AgCl (0.1M AgNO$_2$ in acetonitrile) electrode. Coulometry reveals that the number of electrons involved in each oxidation peaks is in the range of 1.2∼1.3 respectively. Neutral imine radical was produced by fast deprotonation of SP radical cation formed by oxidation of one nitrogen atom in SP. Two pathways are possible for the reaction of the neutral radical: Due to the disproportionation of the radical, SP and enamine were mainly produced. Also, the 1,2-dehydrosparteinium cation was formed as minor product through the second one electron transfer oxidation of this radical. The (+)-lupanine was produced by treatment of sparteinium cation with potassium hydroxide. We have isolated and confirmed the electrolysis products using IR, GC-MS, UV-Vis, and thin-layer spectroelectrochemical method.

  • PDF

Anodic Reactions at a Pb-Ag Anode in Sulfuric Acid Solutions Containing Manganese(II) (망간(II)을 함유한 황산용액에서 Pb-Ag 양극의 산화반응)

  • Lee, Man-Seung;Nicol, M.J.
    • Resources Recycling
    • /
    • v.26 no.4
    • /
    • pp.34-41
    • /
    • 2017
  • The effect of Mn(II) concentration on the anodic reactions occurring on a Pb-Ag electrode in sulfuric acid solutions has been studied by potentiostatic oxidation in the potential range of 1.8 to 2.0 V. High oxidation potentials and low initial concentrations of Mn(II) resulted in higher concentrations of soluble Mn(III) ions which were obtained from spectrophotometric analysis of the solution after oxidation. $MnO_2$ was deposited on the electrode by electrochemical oxidation of Mn(II) at 1.8 and 1.9 V, while it was formed by disproportionation of Mn(III) at 2.0 V. No $PbO_2$ was formed in the presence of Mn(II) during potentiostatic oxidation treatment for two hours at 1.8 V. Chemical reduction of $PbO_2$ with Mn(II) led to a decrease in the amount of $PbO_2$ as Mn(II) concentration increased at 1.9 and 2.0 V.

A Strategy for Improving the Sewerage Systems of Two Rural Areas in Gyeonggi Province (경기도의 2개 시.군 사례를 통한 농어촌지역 하수도 정비 추진 방안)

  • Moon, Chul-Hwan;Ahn, Ji-Hoon;Jang, Mi-Jeong;Lee, Sang-Hyup;Cho, Young-Moo;Kim, Yun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.563-580
    • /
    • 2010
  • In 2009 the Korea Ministry of Environment announced 'A Comprehensive Plan for the Improvement of Sewer Service in Rural Area' aiming at reduction of the sewer service gap between urban and rural areas as well as improvement in the residential environment of the rural area. According to the plan, the sewer system supply rate for the rural area is expected to reach up to 75% until 2015 with the budget of 4.7 trillion won (Korean currency). It is not certain, however, that the increase in the sewer system supply rate will accompany improvement of water quality in receiving water because several veiled problems that can occur in small-scale sewer treatment plants are poorly addressed in the plan. In this study, those issues for the small-scale sewer treatment plants and their solutions were discussed based on a case study in which we investigated 19 treatment facilities at two rural regions in Gyeonggi province. This study also included strategies useful for the plan. From the results of investigation, some problems, e.g., high hourly variations but low in flowrates and low mass loading were commonly identified. Although operation parameters in sewer treatment plants require to be modified depending on the mass loading, most of the plants were operated with the initial design parameters which causes the decrease of removal efficiency. In the intensive diagnosis, we arranged and applied solutions (e.g., flow equalization, air on/off time control, etc) to the two selected plants and found out improvement of effluent water quality, especially organic matters (COD and SS) and T-N with better denitrification performance.