• Title/Summary/Keyword: 분진입자

Search Result 165, Processing Time 0.028 seconds

A Numerical Study on an Optimum Design of a Hybrid Collector Coupled with the Principle of Cyclone, Baffle and Bag-Filter (싸이클론과 배플 및 백필터 원리를 결합한 하이브리드형 집진기의 최적화 설계를 위한 수치해석)

  • Hong, Sung-Gil;Jung, Yu-Jin;Lim, Ki-Hyuk;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.983-989
    • /
    • 2013
  • The current research reviewed the design conditions that would maximize the efficiency of the hybrid collector that combines in one unit "cyclone-inertial impaction-bag filter". The computational analysis for the shape of cyclone entry predicts that a design that installs the guide vane at the entry of the tangential type cyclone brings a high-rpm and powerful vortex, very effective in promoting the deflection of coarse particles from the streamline at the cyclone. As the lower part of the cyclone is venturi-shaped, however, a strong flow downward of 4 to 5 m/sec persists through the lower part of the hopper, revealing the likely reentrainment of collected dust. And the removal of the venturi at the lower part of the cyclone would solve the problem of the reentrainment of collected dust. The acceleration of the flow velocity through the adjustment of the gap of the collision baffle would increase the effect of collision, but as the interference with the dust separation is expected, the original design should be kept for the baffle.

High Temperature Thermal Behavior of EAF Dust by Coke at Initial Reaction Stage (초기 반응단계에서 코크스에 의한 EAF DUST의 고온열적 거동)

  • 정봉진;배상민;문석민;신형기
    • Resources Recycling
    • /
    • v.7 no.5
    • /
    • pp.19-25
    • /
    • 1998
  • High temperature thermal behaviors of EAF dust by coke at initial reaction stage were studied to obtain the fundamental data of EAF dust treatment process, that is Extended Arc Plasma Furnace System called RAPID system. In this study thermal behaviors including calcination of limestone, devolatilization of EAF dust itself, and reduction & devolatilization of mixture(EAF dust : coke : limestone = 80 : 10 : 10 wt.%) were investigated as functions of reaction temperature (1000~1300$^{\circ}C$) and reaction time (3~12 min), considering the 180% equivalence of carbon reduction and 1.7 bacisity for optimum reduction and melting of EAF dust in the RAPID system. Size of sample was about below 0.1 mm for these experiments. Limestone was completely calcined at above 1100$^{\circ}C$ within 1 minutes. In the case of devolatilization of EAF dust itself, weight loss of EAF dust was about 14% at 1300$^{\circ}C$ and 12 minutes, and partial sintering and melting were found in part of sample. Weight loss of mixtures increased with increasing reaction temperature and time, about 46% weight loss in it was occurred at 1300$^{\circ}C$ and 12 minutes. From these weight losses showing devolatilization and reduction of EAF dust, the treatment time of EAF dust inside.

  • PDF

The wintertime distribution of ionic components in Seoul and Busan: Comparative analysis between fine and coarse particles (겨울철 서울과 부산지역의 분진 중 이온분포의 특성 연구: 미세와 조대영역간의 비교)

  • Kim, Ki-Hyun;Kang, Chang-Hee;Choi, Kum Chan;Kim, Young J.
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.230-239
    • /
    • 2004
  • Using our PM2.5 and PM10 concentration data obtained from Seoul and Busan during winter 2002, we conducted comparative analysis on the role of inorganic ions in constituting airborne particles in two distinctive urban areas. Whereas the mass concentration of fine particle was more significant in Seoul, no such pattern was found in Busan. In addition, when the major components were compared between different particle fractions and between different sites, clear pattern was apparent between those. Although the major components of fine particles were generally compatible each other ($NH{_4}^+$, $NO{_3}^-$, and NSSS), those of coarse fractions were clearly distinguished. Although anthropogenic signatures were still important in Seoul, the influence of oceanic sources was clear in coarse fraction of Busan ($Cl^-$ and $Na^+$). Detailed statistical analysis of our data consistently supports the importance of different source processes between particle modes and source processes.

A Study on Numerical Calculations of Multi-stage Dedust System coupled with the Collection Principle of Cyclone, Inertial Impaction and Bag filter (I) : Optimized Design of Dedust inlet (사이클론과 관성충돌 및 백필터의 제진원리를 일체화한 멀티 제진시스템의 수치 해석적 연구 (I) : 집진기 입구 최적화 설계)

  • Jung, Yu-Jin;Jeong, Moon-Heon;Park, Ki-Woo;Hong, Sung-Gil;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.367-370
    • /
    • 2012
  • 본 연구는 하나의 장치 내에서 "싸이클론-관성충돌-여과포 집진"이라는 다단 제진 단계가 동시에 이루어져 입경 분포별로 순차적인 제진이 가능한 멀티 집진기의 처리가스 제어 효율을 극대화시킬 수 있는 기류 흐름을 얻기 위한 최적화 설계 조건을 검토하는 것이다. 우선 1단계 제진 과정인 원심력을 이용하여 조대입자의 유선 이탈을 촉진시킬 수 있는 사이클론 유동을 최적화시키기 위한 집진기 입구 형상 설계 검토를 위해 수치 해석적 연구를 수행하였다. 그 결과, 멀티집진기 입구 형상을 일반적인 설계 방식인 접선 유입식으로만 설계한 것에 비해 선회류를 한번 더 가속화시킬 수 있는 가이드 베인을 추가로 설계한 경우 선회류의 pitch가 짧고 강하게 형성되어 사이클론부에서 조대입자의 유선 이탈을 촉진시키는데 매우 효과적인 것으로 예측되었다. 단, 사이클론부 하단 벤츄리 형상으로 인해 약 4~5 m/s의 강한 하향 흐름이 호퍼 하단까지 형성되고 있어 탈리 분진의 재비산 문제가 발생할 가능성이 크므로 벤츄리 형상 설치 유무에 대한 영향도 추가적으로 연구가 필요할 것으로 판단된다.

  • PDF

The distribution characteristics of trace elements of fine ambient particulate in Korea

  • Lim, Jong-Myoung;Lee, Jin-Hong;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.241-249
    • /
    • 2005
  • In this study, instrumental neutron activation analysis was used to measure the concentrations of about 30 trace elements in airborne particulate (PM2.5) samples at urban area of Daejeon city located in the southwestern region of Korea. An inspection of the measurement data indicates that the distribution patterns of trace elements could clearly distinguish the elements with their concentrations ranging over five orders of magnitude. The mean values for Lu and Dy were found to be the lowest at values of 0.01 and $0.04ng/m^3$, while those for K and Fe showed the highest value of 671 and $653ng/m^3$, respectively. The results of correlation analysis showed that PM2.5 concentrations can exhibit much more enhanced correlations with the elements of earth crustal components. The results of factor analysis further indicated that there are no more than six factors with statistical significance, which may exert dominant roles in regulating the elemental concentration levels in the study area. Enrichment factor analysis supports explicit interpretation of results found by this factor analysis.

Conversion Rate of Gaseous Ammonia to Particulate Ammonium During Atmospheric Transport (대기 수송중 암모니아의 암모늄염으로의 전환속도)

  • Kim Hui-Kang;Y. Hashimoto;Yong-Kuen Lee
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.2
    • /
    • pp.88-94
    • /
    • 1982
  • The concentrations of gaseous ammonia and particulate ammonium emitted from a urea plan were measured, and the conversion rate of ammonia to ammonium was estimated. The conversion of ammonia to ammonium has two stages with transport time in the atmosphere. In the initial 15min the conversion rate was 3.2% min$^{-1}$, and thereafter 0.26% min$^{-1}$. The high conversion rate of ammonia to ammonium at the initial period of it's transport might be due to the dissolution of ammonia into water droplets formed by the decrease in temperature of the stack effluent. The concentration of ammonium is further increased by the decomposition of urea in alkaline droplet formed. Half-lives of ammonia gas at initial and latter slag were 16 min and 192 min respectively. No correlation of particulate ammonium concentration to temperature, relative humidity, and concentrations of sulfur dioxide, nitrogen oxides and airborne particulate matter were found in this field measurement.

  • PDF

Occupational exposure to dust and respirable quartz in coal briquettes ash handling worker (연탄재 처리 환경미화원의 분진 및 호흡성 석영 노출)

  • Kim, Boowook
    • Particle and aerosol research
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study is to assess respirable crystalline silica (RCS) exposure levels in workers who collect and dispose used coal briquette ash (CBA) in sanitation companies that are subcontracted by one medium-sized local government on the collection of municipal household waste (MHW), and to analyze the quartz content in CBA. When the CBA powder that undergone specialized pretreatment in several steps were subjected to mineral identification and quantitative analysis using X-ray diffraction (XRD), it was found that quartz represented 18%, and in addition, mullite, and plagioclase were included. For two CBA collectors, samples were collected by the personal sampling evaluation method. After respirable dust was collected in accordance with the National Institute for Occupational Safety and Health 7500 method, the concentration of quartz was analyzed using XRD. Meanwhile, a portable real-time dust monitor (Sidepak AM520, TSI Inc., USA) was also used to observe the dust exposure level for each time zone and job task. The RCS exposure level of one worker was as high as 0.024 mg/㎥, which was the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLV) level. The other worker also exhibited a concentration of 0.013 mg/㎥, which was more than half of TLV. The Sidepak results revealed that the work of collecting CBA and loading it onto a vehicle was hardly exposed to the dust of a significant level. It was found, however, that the work of transferring the collected CBA to a container through a conveyor belt was exposed to a very high average respirable dust concentration of 2.238 mg/㎥. The results of this study confirmed that quartz, which is crystalline silica and a carcinogen, is contained in CBA, one of municipal household waste (MHW), in high concentration. It was also confirmed that workers are exposed to high RCS concentrations while transferring collected CBA into a container. Although each local government in South Korea handles CBA in different ways, it is imperative to investigate the CBA exposure level of sanitation workers and improve their working conditions.

A Study on Characteristics of Pollutant by Automobile in Highway Road Runoff (고속도로 강우유출수 내 차량 기인 오염물질 특성 연구)

  • Yong Bin An;Eun Mi Hong;Hyuck Su Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.232-232
    • /
    • 2023
  • 고속도로 및 편의시설 건설로 불투수층의 면적이 증가하여 강우 시 고속도로 및 편의시설에서 발생하는 오염원에 의한 하천의 수질 영향도 커지고 있다. 특히 휴게소에서는 자동차의 급가속, 급감속으로 더욱 많은 분진과 오염물질이 발생할 수 있으며 타이어 마모 입자, 자동차 배기가스, 중금속 및 오일류 등이 휴게소나 도로 지표에 집적되어 있다. 이렇게 발생한 오염물질은 우기에 강우와 함께 불투수면을 침투하지 못하고 배수로를 통해 유출되어 인근 하천의 수생태 및 토양의 주요 오염원으로 작용하고 있다. 이에 따라 고속도로 및 인근 휴게소의 비점오염 저감대책이 필요하며 효율적인 비점오염원 저감을 위해 장기적인 모니터링, 지속적인 자료 수집 및 분석이 필요하다. 본 연구에서는 강원지역 고속도로 및 인근 휴게소에서 강우 시 강우유출수 모니터링을 통해 강우유출수 유량가중평균농도 (Event Mean Concentration) 산정하고 강우유출수 수문곡선 (hydrograph)을 작성하였다. 또한 강우사상에 따른 분석항목별 초기세척효과(First Flush Effects)와 오염부하량을 산정하였다. 추가적으로 차량 기인 입자를 확인하기 위해 μ-FT-IR 현미경 분석 실험을 하였다. 모니터링 장소는 휴게소 및 고속도로 일원이며, 모니터링은 선행무강우일수 2일 이상, 강우량 10mm 이상일 때 실시하였으며 2022년 6월부터 10월까지 총 4회 실시하였다. 모니터링 결과 타이어 및 브레이크 패드 마모와 관련된 중금속인 Zn, Cu, Pb 등의 중금속이 높게 분석되었으며 이러한 중금속의 오염부하량 역시 높게 산정되었다. 강우유출수 수문곡선에서 강우 초기 오염물질의 세척효과가 나타났다. MFFn 산정 결과 강우 30% 구간에서 초기세척효과를 보였다. μ-FT-IR 현미경 분석 결과 PE (Polyethylene)가 가장 많이 검출되었고 PP (Polypropylene), PS (Polystyrene) 순으로 검출되었다. 이러한 강우유출수 모니터링 데이터는 향후 고속도로 휴게소 및 고속도로 주변 오염저감 시설 설치 및 사회적 동참을 위한 타당한 근거 확보를 위한 기초자료로서 제공될 수 있을 것이다.

  • PDF

An Analysis on the Episodes of Large-scale Transport of Natural Airborne Particles and Anthropogenically Affected Particles from Different Sources in the East Asian Continent in 2008 (2008년 동아시아 대륙으로부터 기원이 다른 먼지와 인위적 오염 입자의 광역적 이동 사례에 대한 분석)

  • Kim, Hak-Sung;Yoon, Ma-Byong;Sohn, Jung-Joo
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.600-607
    • /
    • 2010
  • In 2008, multiple episodes of large-scale transport of natural airborne particles and anthropogenically affected particles from different sources in the East Asian continent were identified in the National Oceanic and Atmospheric Administration (NOAA) satellite RGB-composite images and the mass concentrations of ground level particulate matters. To analyze the aerosol size distribution during the large-scale transport of atmospheric aerosols, both aerosol optical depth (AOD; proportional to the aerosol total loading in the vertical column) and fine aerosol weighting (FW; fractional contribution of fine aerosol to the total AOD) of Moderate resolution Imaging Spectroradiometer (MODIS) aerosol products were used over the East Asian region. The six episodes of massive natural airborne particles were observed at Cheongwon, originating from sandstorms in northern China, Mongolia and the loess plateau of China. The $PM_{10}$ and $PM_{2.5}$ stood at 70% and 16% of the total mass concentration of TSP, respectively. However, the mass concentration of $PM_{2.5}$ among TSP increased as high as 23% in the episode in which they were flowing in by way f the industrial area in east China. In the other five episodes of anthropogenically affected particles that flowed into the Korean Peninsula from east China, the mass concentrations of $PM_{10}$ and $PM_{2.5}$ among TSP reached 82% and 65%, respectively. The average AOD for the large-scale transport of anthropogenically affected particle episodes in the East Asian region was measured at $0.42{\pm}0.17$ compared with AOD ($0.36{\pm}0.13$) for the natural airborne particle episodes. Particularly, the regions covering east China, the Yellow Sea, the Korean Peninsula, and the east Korean sea were characterized by high levels of AOD. The average FW values observed during the event of anthropogenically affected aerosols ($0.63{\pm}0.16$) were moderately higher than those of natural airborne particles ($0.52{\pm}0.13$). This observation suggests that anthropogenically affected particles contribute greatly to the atmospheric aerosols in East Asia.

Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber (입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교)

  • Park, Ju-Myon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.