• Title/Summary/Keyword: 분석법

Search Result 26,403, Processing Time 0.052 seconds

A Study on the Effective Approaches to Big Data Planning (효과적인 빅데이터분석 기획 접근법에 대한 융합적 고찰)

  • Namn, Su Hyeon;Noh, Kyoo-Sung
    • Journal of Digital Convergence
    • /
    • v.13 no.1
    • /
    • pp.227-235
    • /
    • 2015
  • Big data analysis is a means of organizational problem solving. For an effective problem solving, approaches to problem solving should take into account the factors such as characteristics of problem, types and availability of data, data analytic capability, and technical capability. In this article we propose three approaches: logical top-down, data driven bottom-up, and prototyping for overcoming undefined problem circumstances. In particular we look into the relationship of creative problem solving with the bottom-up approach. Based on the organizational data governance and data analytic capability, we also derive strategic issues concerning the sourcing of big data analysis.

Conventional Analytical and New Raman Spectroscopy-Based Methods for Detecting Benzo[a]pyrene in Food: Review and Perspective (식품 내 벤조피렌 분석법의 기존 연구동향 및 라만분광법 기반기술 전망)

  • Lee, Mi-Hyun;Yee, So-Yoon;Jin, Xuanyan;Choi, Dae Sik;Rhee, Hanju;Rhee, Jin-Kyu
    • Microbiology and Biotechnology Letters
    • /
    • v.43 no.3
    • /
    • pp.177-186
    • /
    • 2015
  • With a view to supporting the provisions of the current Korean food code for the detection of Benzo[a]pyrene, various analytical methods of detection in foods were evaluated and established in terms of linearity, limits of detection/quantitation, efficiency, and accuracy, amongst others. It was observed that to improve the technologies involved in the application of these methods, complicated and combined preparation processes of foods, including extraction, separation and purification, have been the main focus of efforts at optimization. Recently, on-site quick reaction for the detection of hazardous substances in the environment and food materials aims at developing simplified examination processes, such as lable-free and non-invasive technological analysis, to reduce the costs and time involved in the examination. Herein, current benzo[a]pyrene detection methods are reviewed in addition to new Raman spectroscopy-based trials established to pursue improve the speed, simplicity and suitability of testing.

Detection of Hepatitis B Virus by LAMP and DHPLC (등온증폭반응법과 변성 고성능 액체 크로마토그래피를 이용한 B형 간염 바이러스의 검출)

  • Ahn, Young-Chang;Seo, Jae-Won;Choi, Jae-Gu;Jang, Won-Cheoul
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.262-267
    • /
    • 2011
  • The denaturing high performance liquid chromatography(DHPLC) with fluorescence detector assay is very useful tool for detecting nucleic acids. Furthermore, loop-mediated isothermal amplification(LAMP) constitutes a potentially valuable tool for rapid diagnosis of pathogenic microorganisms. In this study, we evaluated the specificity, detection limit, and sensitivity of a LAMP method and DHPLC method for rapid detection of the hepatitis b virus(HBV). As a result, the LAMP assay reported here has the advantage of rapid detection whereas, DHPLC assay has more sensitivity than other assays. These findings suggest that LAMP and DHPLC assay may be good tool for rapid diagnosis of clinical HBV infection.

Impurity analysis and acid leaching purification of silica minerals (실리카광물의 산침출 정제와 불순물 분석법 연구)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Cho, Soo Young;Chae, Young-Bae
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.516-523
    • /
    • 2007
  • Purification of silica mineral has been investigated by acid leaching of pulverized silica. A series of studies has been carried out on the effect of leaching silica powder as a function of the leaching time at the constant temperature of $80^{\circ}C$ in oxalic acid, aqua regia, and two mixed acids of HF/HCl, $HF/HNO_3$. The impurities of silica and leachantes were measured by neutron activation analysis (NAA), inductively coupled plasma atomic emission spectrometry (ICP-AES), atomic absorption spectrometry, x-ray fluorescence (XRF) method and wet analysis (WA). Certain metals, such as sodium, calcium, iron, aluminium and titanium, have been found in concentrations of hundreds or even thousands of mg/kg. Comparison of purification processes of silica and analytical methods of impurities in the silica was conducted in this study.

Validation of an analytical method of dieckol for standardization of Ecklonia cava extract as a functional ingredient (감태추출물의 기능성원료 표준화를 위한 지표성분 dieckol의 분석법 검증)

  • Xu, Yan;Kim, Eun Suh;Lee, Ji-Soo;Kim, Gun-Hee;Lee, Hyeon Gyu
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.420-424
    • /
    • 2019
  • An HPLC analysis method was developed and standardized for the detection of dieckol as a functional food ingredient in Ecklonia cava extracts. HPLC was performed using a Capcell Pak C18 column ($250{\times}4.6mm$, $5{\mu}m$) with a gradient elution of water and acetonitrile, both containing 0.1% (v/v) trifluoroacetic acid, at a flow rate of 1.0 mL/min at $25^{\circ}C$. The eluate was detected at 230 nm. For validation, the specificity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ) of dieckol were measured. The calibration curve for the detection of dieckol had high linearity ($R^2=0.9994$), with LOD and LOQ values of 0.38 and $1.16{\mu}g/mL$, respectively. Recovery of the quantified compound ranged from 99.61 to 100.71%. The relative standard deviation values of the intra-day and inter-day precisions were less than 1.7 and 1.25%, respectively. These results indicate that the reported HPLC method is simple, reliable, and reproducible for the detection of dieckol in Ecklonia cava extracts.

Simulation of the Degradation Detecting Signal Using Pattern Analysis Method (패턴 분석법을 이용한 열화 검출 신호 시뮬레이션)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.341-342
    • /
    • 2013
  • 본 연구에서는 배전선로의 내부 부식을 진단하는 방법이 미흡하여 예기치 못한 사고가 빈번히 발생하는 현실을 감안하여 이에 대한 대책으로 와류탐상법을 이용하여 배전선로의 내부 부식 신호를 검출한 후, 와류 탐상 신호가 매우 민감한 신호임을 고려하여 내부 부식에 대한 보다 정확한 분석을 할 수 있도록 패턴 해석 방법인 군집화기법을 이용하여 와류 탐상 신호에 대한 시뮬레이션을 수행하였으며, 배전선로의 열화 정도를 제시하기 위해 물성 변화 및 인장력을 각각 조사하였다.

  • PDF

원예용 상토의 규격화 및 표준분석법

  • 김이열
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.11a
    • /
    • pp.131-186
    • /
    • 2002
  • 우리나라 유통상토에 대한 물리적 표준분석법을 설정하기 위한 연구를 실시하였다. 국내 시중에 유통되고 있는 53개 품목의 원예용 상토와 9개 품목의 수도용 상토를 대상으로 설정된 분석법을 적용하여 실험하였다. 입자밀도의 측정은 가스형 피크노메타(Micromeritics Co. Model 1305)를 사용하면 속도와 정확성 면에서 매우 유리하였다. 용적밀도는 구미에서 Sandbox법에 의한 용적밀도를 기본으로 하기 때문에 이와 유사한 성적을 얻을 수 있는 다양한 실험을 한 결과, 추다짐법(Plunger compaction method)이 가장 유의성 있는 측정 방법으로 밝혀졌다. 한편 가스형 피크노메타법에 의한 우리나라 유통상토의 입자밀도는 원예용이 1.93, 수도용이 2.43 Mg m$^{-3}$로 나타났으며, 추다짐법에 의한 용적밀도는 원예용이 0.22, 수도용이 1.01 Mg m$^{-3}$로 각각 나타났다. 수분함량은 105$^{\circ}C$ 건조기에서 16시간 건조하여 수도용상토는 (최초 무게-건조 후 무게) / (건조 후 무게) $\times$ 100으로, 원예용상토는 (최초무게 - 건조 후 무게) / (최초 무게) $\times$ 100으로 하였다. 보수력은 주로 저압용으로서 Eijkelkamp사의 Sandbox법을 사용하여 0.5, 1, 3, 5, 7, 10 ㎪의 수분장력 상태의 수분함량을 조사하였다. 포화수리전도도는 직경 5cm$\times$높이 20cm인 아크릴 원통을 이용하여 정수위별에 의한 포화수리전도도를 측정하였다. 신분석법에 의한 유통상토의 수분함량은 원예용이 평균 46.34%, 수도용이 평균 16.89%이었고 원예용 상토의 EAW는 28.4%, WBC 7.01%, OMP는 5.60 ㎪로 나타났으며, 육묘를 위한 적정 수분함량은 44.41%이었고 포화수리전도도는 1.71 cm $min^{-1}$이었다. 상토 평량시 무게를 비교한 결과 상토 부피를 달리하여도 고도의 유의성이 있었고, 상토 20cc의 평균무게는 4.92g(2.08-8.83g)이었다. 상토의 EC 측정시 상토:물의 비율이 1:2(v:v)와 1:5(v:v)분석치에 2.5배한 EC 값과는 고도의 정의 상관관계가 있었으며, 유럽법과 일본법(전농)과의 관계는 고도의 정의 상관관계가 있었다 또한 새로운 분석법(v:v 1:5)으로 측정한 EC의 평균값은 국내산 0.64, 수입산 0.33 dS m$^{-1}$이 었다. 상토의 pH 측정시 상토:물의 비율을 1:2(v:v)와 1:5(v:v)와의 관계에서는 정의 상관관계를 보였으며, 유럽법과 일본법(전농)과의 관계도 역시 고도의 정의 상관관계가 있었고, 신 분석법에(v:v 1:5) 의한 분포비율은 국내산, 수입산모두 pH 6.1-6.5의 범위에서 가장 높았다.

  • PDF

Uncertainty Evaluation of NOx Measurement in Ambient Air (환경대기 중 NOx 측정의 불확도 평가)

  • 임종명;이진홍;우진춘
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.141-142
    • /
    • 2002
  • 대기환경 기준물질(criteria pollutants)은 NOx를 비롯하여 $O_3$, CO, SOx, PM 10, Pb 인데, 이러한 물질은 환경부에서 법적으로 규정한 대기오염공정 시험법에 따라서 분석된다. 대기오염공정 시험법이 충분한 과학적 근거를 갖는 분석법이 되기 위해서는 분석방법, 분석기기, 분석자 등에 의해 발생되는 불확실성을 최소화시키는 체계적인 관리가 필요하고, 분석기술의 발달수준, 측정분석의 요구수준, 새로운 국제 규격 통에 맞게 지속적으로 보완되어야 한다. (중략)

  • PDF

Measurements of Adhesion Strength Using Scratch Test (스크래치 시험을 통한 접합력 측정)

  • Lee, Chang-Myeon;Heo, Jin-Yeong;Lee, Hong-Gi
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.354-354
    • /
    • 2015
  • 코팅 층과 소지 사이의 접합력 평가를 위하여 박리 시험법(Peel Off Test), 블리스터 시험법(Blister Test), 압입균열 시험법(Indentation Test), 직접 인장 시험법(Direct Full Off Test), 스카치 테이프 시험법(Scotch Tape Test), 그리고 스크래치 시험법(Scratch Test) 등이 사용되어 왔다. 이 중 박리 시험법과 스카치 테이프 시험법이 산업계에서 일반적으로 사용되고 있다. 전자 산업계에서 많이 사용되고 있는 박리시험법은 금속박막과 절연체 기판 사이의 접합력을 간단하게 측정할 수 있으며, 실험값의 재현성이 뛰어난 장점이 있다. 또한, 측정하는 동안 만들어지는 박리 곡선(Peel Curve)로부터 분석의 신뢰성 여부를 확인할 수 있다. 이러한 장점에도 불구하고 박리 시험법 특성 상 금속 코팅층의 강도가 금속 피막/기판간 접합 강도를 초과하여야 하기 때문에 수백 nm 이하의 박막의 접합력 측정에는 적용하기가 어렵다. 이에 반하여, 스카치 테이프 분석법은 일정길이의 접착 테이프를 박막 표면에 붙인 후 다시 떼어내면서 접착력을 평가하는 방법으로, 박막의 접합력 평가에 적용이 가능하다. 그러나 이 방법은 합격 불합격 여부를 판정하는 정성적인 방법으로 정량평가가 어렵다. 또한, 박막에 접착 테이프를 붙일때의 압력, 테이프를 박리할 때의 각도 및 속도를 일정하게 제어하기가 쉽지 않아 결과의 신뢰성이 높지 않다. 스크래치 테스트는 탐사침(Stylus)을 이용하여 박막의 표면에 하중을 증가시키면서 기판을 이동하여, 피막의 균열이나 박리될 때의 임계 하중값 (Critical Load; Lc)을 측정하는 방법이다. 이 방법은 시편 준비가 쉽고 간단하여 빠른 분석이 가능하고, 수백 nm 이하의 박막에도 적용 가능하다. 또한, 접합력을 정량화 할 수 있기 때문에 변수에 따른 접합력 비교가 용이하다는 장점이 있다. 이와 같은 분석적 장점에도 불구하고, 스크래치 시험을 통한 접합력 측정 방법은 아직까진 산업적으로 널리 활용되지 못하고 있다. 따라서, 본 연구에서는 스크래치 테스트의 원리 및 이론에 대하여 간략히 알아보고, 스크래치 분석을 이용한 접합력 비교에 대한 실제 사례들을 소개하고자 하였다.

  • PDF

Comparison of Colorimetry and HPLC Method for Quantitative Analysis of Chitooligosaccharide (키토올리고당의 측정법으로 비색법과 HPLC법의 비교)

  • Kang, Kil-Jin;Cho, Jung-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.788-791
    • /
    • 2000
  • The quantitative analysis of chitooligosaccharide was compared to using colorimetry and HPLC method. HPLC method required less than 10mins per sample in analytical time of glucosamine and its the recovery rate was 98.4% (10 mg/ml, w/v). Also there was no the effects of interfering substances(false positive response) by HPLC method. The content of chitooligosaccharide in processed chitooligosaccharide products obtained using HPLC showed lower levels compared to colorimetry. Thus, HPLC method was more sensitive, effective and precise than the colorimetry currently used to determine the glucosamine of chitooligosaccharide.

  • PDF