• Title/Summary/Keyword: 분무-벽 충돌 모델

Search Result 7, Processing Time 0.019 seconds

Modeling of Wall Impingement Process of Hollow-Cone Fuel Spray according to Wall Geometry (벽면 형상에 따른 중공 원추형 분무의 벽 충돌 과정 모델링)

  • Shim, Young-Sam;Choi, Gyung-Min;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3467-3472
    • /
    • 2007
  • The effects of the wall geometry on the spray-wall impingement process of a hollow-cone fuel spray emerging from a high-pressure swirl injector of the Gasoline Direct Injection (GDI) engine were investigated by means of a numerical method. The ized Instability Sheet Atomization (LISA) & Aerodynamically Progressed Taylor Analogy Breakup (APTAB) model for spray atomization process and the Gosman model were applied to model the atomization and wall impingement process of the spray. The calculation results of spray characteristics, such as a spray development process and a radial distance after wall impingement, compared with the experimental ones by the Laser Induced Exciplex Fluorescence (LIEF) technique. It was found that the radial distance of the cavity angle of 90$^{circ]$ after wall impingement was the shortest and the ring shaped vortex was generated near the wall after spray-wall impingement process.

  • PDF

Study of Spray Droplet/Wall Interaction (분무액적과 벽의 상호작용에 대한 연구)

  • 양희천;유홍선;정연태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.4
    • /
    • pp.86-100
    • /
    • 1998
  • The impingement of the fuel spray on the wall within the combustion chamber in compact high-pressure injection engines and on the intake port wall in port-fuel-inje- ction type engines is unavoidable. It is important to understand the characteristics of impinging spray because it influences on the rate of fuel evaporation and droplet distrib- ution etc. In this study, the numerical study for the characteristics of spray/wall interaction is performed to test the applicability and reliability of spray/wall impingement models. The impingement models used are stick model, reflect model, jet model and Watkins and Park's model. The head of wall-jet eminating radilly outward from the spray impingement site contains a vortex. Small droplets are deflected away from the wall by the stagnation flow field and the gas wall-jet flow. While the larger droplets with correspondingly higher momentum are impinged on the wall surface and them are moved along the wall and are rolled up by wall-jet vortex. Using the Watkins and Park's model the predicted results show the most reasonable trend. The rate of increase of spread and the height of the developing wall-spray is predicted to decrease with increased ambient pressure(gas density).

  • PDF

A Study on Atomization and Wall Impingement Process of Hollow-Cone Fuel Spray (중공 원추형 연료 분무의 미립화 및 벽 충돌 과정에 대한 연구)

  • Shim, Young-Sam;Choi, Gyung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.132-138
    • /
    • 2006
  • Numerical analysis about atomization and wall impingement process of hollow-cone fuel spray is performed by a modified KIVA code with hybrid model. The atomization process is modeled by using hybrid breakup model that is composed of Linearized Instability Sheet Atomization(LISA) model and Aerodynamically Progressed Taylor Analogy Breakup(APTAB) model. The Gosman model, which is based on the droplet behaviors after impingement determined by experimental correlations, is used for spray-wall impingement process. The LIEF technique was used to compare the results with those of experiment. The calculations and experiments are carried out at the ambient pressures of 0.1 MPa and 0.5 MPa and the ambient temperature of 293K. It was found that the calculated results show satisfactory agreement with experimental ones.

A Numerical Model for Atomization of an Impinging Spray on the Wall (벽면에 충돌하는 분무의 미립화에 관한 수치적 모델)

  • Joh, Mi-Ok;Huh, Kang-Y.
    • Journal of ILASS-Korea
    • /
    • v.2 no.1
    • /
    • pp.36-45
    • /
    • 1997
  • A spray-wall impingement model for fuel sprays is proposed and implemented as a module into the KIVA-POSTECH code. The model is based on the single droplet experiments. The droplet behaviors after impingement are determined from experimental correlations. Different behaviors of impinged droplets depend on the wall temperature and the critical temperature of the fuel. Fuel film formation is taken into account so that the model can be applicable to any wall temperature and injection conditions. Computational results on a normal and on inclined wall are in good agreement for the spray shape and penetration. More validation against experiments and development of the heat transfer model are needed for further improvement.

  • PDF

Numerical Study on Wall Impingement Process of GDI Spray According to Wall Cavity Angle (벽면 캐비티 각에 따른 GDI 분무의 벽 충돌 과정에 대한 수치적 연구)

  • Shim, Young-Sam;Kim, Duck-Jool;Choi, Gyung-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.971-978
    • /
    • 2007
  • A spray-wall impingement process of a hollow-cone fuel spray from the high-pressure swirl injector in the Gasoline Direct Injection (GDI) engine were experimented and calculated at various wall geometries. The Linearized Instability Sheet Atomization (LISA) & the Aerodynamically Progressed Taylor Analogy Breakup (APTAB) model and the Gosman model were applied to model the breakup and the wall impingement process of the hollow-cone fuel spray. The numerical modelings were implemented in the modified KIVA code. The calculation results of spray characteristics, such as a spray development process and a radial distance after wall impingement, compared with the experimental results by the Laser Induced Exciplex Fluorescence (LIEF) technique. The droplet size distribution and the ambient gas velocity field, which are generally difficult to obtain by the experimental methods, were also calculated and discussed. It was found that the radial distance after wall impingement and Sauter Mean Diameter (SMD) decreased with increasing a cavity angle.

Experimental and Numerical Study on Behavior of Impinging Spray according to Ambient Temperature (분위기 온도에 따른 충돌 분무의 거동에 대한 실험 및 수치적 연구)

  • Shim, Young-Sam;Choi, Gyung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.124-131
    • /
    • 2007
  • The numerical study on behavior of impinging spray from high-pressure swirl injector under various ambient temperatures was performed by using spray vaporization model and spray-wall impingement model implemented in modified KIVA code, and these spray models were estimated by comparison with experimental results. To compute the spray-wall impingement process, the Gosman model, which is based on the droplet behavior after impingement determined by experimental correlations, was used. The modified Abramzon and Sirignano model, that includes the effects of variable thermodynamic properties and non-unitary Lewis number in the gas film, was adapted for spray vaporization process. The exciplex fluorescence measurements were also conducted for comparison. The experimental and numerical analysis were carried out at the ambient pressures of 0.1 MPa and at the ambient temperature of 293 K and 473 K, and the spray characteristics, such as spray-wall impingement process, gas velocity field, SMD and vapor concentration, were acquired. It was found that the impinging spray develops active and SMD is small at vaporization conditions.

Modeling of Spray-Wall Interactions Considering Liquid Film Formation (액막형성을 고려한 분무-벽 상호작용에 대한 모델)

  • Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.1010-1019
    • /
    • 2000
  • The main purpose of this article is to propose and assess a new spray impingement model considering film formation, which is capable of describing the droplet distribution and film flows in direct injection diesel engines. The spray-wall interaction model includes several mathematical formulae, newly made by the energy conservation law and some experimental results. The model consists of three representative regimes, rebound, deposition and splash. In addition, the film flow is described in the present model by solving the continuity and momentum equations for film flows using the integral method. To assess the new spray impingement model, the calculated results using the new model are compared with several experimental data for the normally impinging diesel sprays. The film model is also validated through comparing film radius and thickness against experimental data. The results show that the new model is generally in better agreement with experimental data and acceptable for prediction of the film radius and thickness.