분무냉각에 있어서 임계열유속 상관식에 관한 연구 (Study on Correlation of Critical Heat Flux in Spray Cooling)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제23권3호
    • /
    • pp.109-113
    • /
    • 2018
  • The critical heat flux of spray cooling were measured on the test surface of 10 mm diameter made by stainless steel. The experiments were carried out for the droplet-flow-rate of $0.00002{\sim}0.003m^3/(m^2s)$ and liquid subcooling temperature of $40{\sim}75^{\circ}C$. Experimental results showed that the critical heat flux of spray cooling increased remarkably with the increase of droplet-flow-rate. Meanwhile, the effect of liquid subcooling on critical heat flux of spray cooling appeared weakly under the present experimental conditions. In additions, correlation between the dimensionless critical heat flux and Weber number based on droplet-floe-rate was developed for experimental results.

신회유동을 갖는 압력식 분무기의 분무특성에 관한 연구 (An Experimental Study on the Spray Characteristics of the Pressure Swirl Atomizer)

  • 조대진;윤석주
    • 한국분무공학회지
    • /
    • 제2권1호
    • /
    • pp.46-51
    • /
    • 1997
  • In this study, spray characteristics of the pressure swirl atomizer have teen investigated. Four atomizers with the different orifice diameter and five tangential ports with the different inlet number were fabricated. For the purpose of the measurement of the mean drop sine, Malvern particle sizer was used. And also discharge coefficient was measured and spray cone angle was measured by using shadow graphy method. As a result when the injection pressure was increased, mean drop size was decreased. And the dominant factor which influence on the spray characteristics of pressure swirl atomizer was orifice diameter.

  • PDF

가열 상태의 다공성 판에 충돌하는 액적의 냉각 성능에 대한 기초 연구 (Cooling Effect of a Heated Porous Plate by Droplets Impingement - A Preliminary Study)

  • 류성욱;김우식;이상용
    • 한국분무공학회지
    • /
    • 제14권1호
    • /
    • pp.20-27
    • /
    • 2009
  • In the present work, effects of spray characteristics (droplet size and velocity) on the temperature variation of a heated porous plate (Melamine foam) have been investigated through a series of experiments. Based on the measured data, time required to cool down the hot porous material turned out to be shorten by doing with the smaller droplet size and/or smaller impinging velocity. In particular, the droplet size effect is more prominent than the impinging velocity. The cooling performance in the porous material is directly proportional to the penetration velocity.

  • PDF

Y-JET 2-유체 분무노즐 내부유동의 모델링 (Modeling of Nozzle Flow Inside a Y-JET Twin-Fluid Atomizer)

  • 인왕기;이상용;송시홍
    • 대한기계학회논문집
    • /
    • 제17권7호
    • /
    • pp.1841-1850
    • /
    • 1993
  • A simplified one-dimensional analysis has been performed to predict the local pressure distributions in Y-Jet twin-fluid atomizers. Fluid compressibility was considered both in the gas(air) and two-phase(mixing) ports. The annular-mist flow model was adopted to analyze the flow in the mixing port. A series of experiments also has been performed; the results show that the air flow rate increases and the liquid flow rate decreases with the increase of the air injection pressure and/or with the decrease of the liquid injection pressure. From the measured injection pressures and flow rates, the appropriate constants for the correlations of the pressure loss coefficients and the rate of drop entrainment were decided. The local pressures inside the nozzle by prediction reasonably agree with those by the experiments.

간헐적으로 분사되는 핀틀형 가솔린 분사기의 액적크기와 속도 상관관계에 관한 연구 (A Study on the Correlation of Droplets Size and Velocity of the Pintle Type Gasoline Injector with Intermittent Injection)

  • 강신재;김원태
    • 한국분무공학회지
    • /
    • 제3권1호
    • /
    • pp.34-42
    • /
    • 1998
  • The correlation between the droplets size and the velocity are investigated for an intermittent spray of the pintle type fuel injector employed in a port injection gasoline engine. The analysis such as the mean droplet size, SMD, and velocity under the fixed injection period and varied fuel pressures are conducted utilizing PDPA systems. As results, the experimental data obtained, show that the larger droplet sizes. the higher velocities during the spray tip arrival time, and that at Z=70mm, r=8mm, both droplet sizes and velocities are peak. At the upstream, flow of droplets are dominated by injection pressure, which are more effected inertia force of droplets at the downstream of Z=70mm.

  • PDF

희박 분무영역에서의 분무냉각 막비등 열전달에 관한 연구 (Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1481-1486
    • /
    • 2004
  • This report presents experimental results on the heat transfer coefficients in the boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distribution of a two dimensional dilute spray impinging on hot plate was experimentally investigated. Based on the experimental results, they classified the heat transfer area into the stagnation region and wall-flow region. In the stagnation region, the local heat transfer coefficient relates mainly to the droplet-flow-rate supplied from spray nozzle directly, so the local heat transfer coefficients is good agreement with the predicted values from correlation for spray cooling proposed by former report However, the local heat transfer coefficient in wall-flow region is larger than predicted values, and it is found that the rebounding droplets-flow-rate must be accurately evaluated to predict the local heat transfer coefficient in this region.

  • PDF

가솔린 분무 거동에 미치는 분위기 조건의 영향 (Effect of Ambient Conditions on Spray Behavior of Gasoline Injector)

  • 이창식;이기형;최수천;권상일
    • 한국자동차공학회논문집
    • /
    • 제8권2호
    • /
    • pp.27-32
    • /
    • 2000
  • The main objective of this work is to investigate the effect of ambient conditions on the spray behavior and spray characteristics of high-pressure fuel injector. For this purpose, the effects of ambient pressure and temperature on the spray characteristics have been studied by applying the analysis of visualization system and phase Doppler particle analyzer. In this experiment, the visualization of spray behavior was performed under various ambient gas conditions and injection parameters such as gas temperature, ambient pressure, injection pressure of injector, and axial distance from the nozzle tip. Based on the investigation results, the spray tip penetration and spray width decrease with the increase of ambient gas pressure in the spray chamber. The effects of the spray parameters on the microscopic characteristics of gasoline spray were discussed.

  • PDF

Y-jet 노즐의 출구오리피스 형상이 비대칭 분무에 미치는 영향 (The Effect of the Y-jet Nozzle Exit Orifice Shape on Asymmetric Spray)

  • 백광열;홍정구
    • 한국분무공학회지
    • /
    • 제26권1호
    • /
    • pp.33-39
    • /
    • 2021
  • Y-jet nozzle has a wide fuel flow rate range and turn-down ratio, thus, it is used in industrial boilers, furnace and agricultural atomizer. However, it has asymmetrical spray characteristics due to the nozzle design factors. Therefore, in this study, asymmetric spraying characteristics of the elliptical Y-jet nozzle was studied by using the lab-scale spray apparatus. As a result, the elliptical Y-jet nozzle had lower gas mass flow rate than circular Y-jet nozzle at same gas pressure, because of bigger shear stress due to the wider inner surface at the elliptical Y-jet nozzle. Larger SMD was measured on the elliptical Y-jet nozzle than the circular Y-jet nozzle. When SMD was measured in the X_Axis direction at the same gas mass flow rate, the elliptical Y-jet nozzle with an aspect ratio of 2:1 showed greater asymmetry than the others.

고온 고압기류중을 비행하는 파라핀계 연료액적의 증발에 관한 연구 (An experimental study on the evaporation of paraffin family fuel droplet under high temperature and high pressure)

  • 정성식
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.2125-2131
    • /
    • 1991
  • 본 연구에서는 고온고압의 기류중에 투입된 미소연료액적의 증발에 관한 정보 를 구하여 분무연소기구의 해명을 위한 기초테이터를 제공하려 시도한다.

예혼합 분무화염내의 이중적 액적 연소속도에 관한 관찰 (Observation on Double-droplet Combustion Speed in Premixed Spray Flame)

  • 이치우;심한섭
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.119-126
    • /
    • 2004
  • In order to elucidate the modes of double-droplet combustion speed in premixed spray flame, the difference between flame propagation speed and droplet cluster disappearance speed are experimentally investigated using a premixed spray burner system, It was confirmed that flame speed concerned with premixed-mode combustion in the spray flame was approximately 2.0 m/s in average while mean disappearance speed of droplet clusters, which were dominated by diffusion-mode combustion in downstream of the flame, was evaluated as much as 0.45 m/s. It was clarified that both characteristics of premixed-mode and diffusion-mode combustion in spray flames are of much difference in nature, even though both speed, which are supposed to depend on local properties of the spray itself and flow conditions surrounding droplet clusters, are scattered in experiments.