• Title/Summary/Keyword: 분리수도

Search Result 301, Processing Time 0.024 seconds

Effect of Zeta Potential of Clay and Algae Particles on Flotation Efficiency (점토와 조류입자의 제타전위가 부상분리 효율에 미치는 영향)

  • Choi, Do-Young;Kim, Seong-Jin;Jung, Heung-Jo;Lee, Se-Ill;Paik, Do-Hyeon;Lee, Jae-Wook;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.437-445
    • /
    • 2005
  • Zeta potential is a key parameter of double layer repulsion for individual particles and can usually be used to interpret the trend of coagulation efficiency. This study focused on the measurement of zeta potential of algae and clay under various experimental conditions including water characteristics (pure water, stream water, reservoir water) and coagulant dose (10~50 mg/L). Results showed that the variation of zeta potential was highly sensitive depending on the water characteristics and coagulation conditions. Zeta potential of two genera of algae (anabaena sp. and microcystis sp.) were changed highly with coagulant dosage, especially. On the basis of trajectory analysis, bubble-floc collision efficiency simulated in terms of zeta potential was fitted well with removal efficiency of chlorophyll-a from algae particles. It was found that the control of zeta potential was important for effective removal of algae particles.

Pressure Effect on Ultrafiltration of Used CMP Slurry (한외여과를 이용한 폐 CMP Slurry의 분리에서 압력의 영향)

  • Hong, Seongho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.486-492
    • /
    • 2004
  • CMP (Chemical mechanical polishing) is inevitable process to overcome $0.2{\mu}m$ wire thickness in semiconductor industry. In this study, effect of pressure to separate used CMP slurry into solid and liquid for recycle and reuse by ultrafiltration was investigated. Also, water quality after the ultrafiltration such as turbidity and TDS was evaluated. The material of membrane used in the study was PVDF. The used CMP contained 0.5% of solid content and then concentrated up to 18% by weight. The used CMP can not be concentrated higher than 18% because of viscosity and abrasion of pump. The tested feed pressures were 22.1, 29.4 and 36.8 psi. The results have shown that operating at 36.8 psi has advantages on operation time and total flux. The specific flux showed some variation at 1 to 15 of concentration factor but no difference after 15 of concentration factor. Mass balance of solid at initial stage of the operation showed some unbalance because of deposition of solid on the membrane, which was main reason to reduce flux. Turbidity was very stable at lower than 0.2NTU for 22.1 and 36.8 psi of feed pressure.

Identification of Fusarium leaf spot(Fusarium nivale) newly reported In Korea (수도갈색엽고병(Fusarium nivale)의 동정)

  • Kwon Shin Han;Song Hi Sup;Sohn Cheong Yeol;Yamakuchi Tomio
    • Korean journal of applied entomology
    • /
    • v.12 no.3
    • /
    • pp.121-124
    • /
    • 1973
  • From the new rice variety Tong-il, disease symptoms similar to Fusarium leaf spot reported in Japan was observed in Korea. Causal organism was isolated and identified as Fusarium nivale causing Fusarium leaf spot through the study of conidia shape, ascus formation on diseased spot, and ascospore. These results also showed good agreement with that of other investigators. Under the field condition, marked occurrence of this disease has observed by heavy nitrogen application. The optimum temperature for the growth of this fungus was $24^{\circ}C$.

  • PDF

Application of Coagulation-UF Hybrid Membrane Process for Reuse of Secondary Effluent (하수 2차 처리수 재이용을 위한 hybrid 응집-UF 막분리 공정의 적용)

  • Lee, Chul-Woo;Shon, Jung-Ki;Shon, In-Shik;Han, Seung-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.605-612
    • /
    • 2005
  • The objective of this study was to evaluate the factors affecting the optimization of coagulation hybrid UF membrane processes for the reuse of secondary effluent from sewage treatment plant. The experimental results obtained from the UF membrane process showed that organic colloids in the size range of $0.2{\mu}m{\sim}1.0{\mu}m$ caused the most substantial influence on the fouling of UF membrane. When using a coagulation pretreatment to UF membrane, alum dosage of 50mg/L resulted in the least reduction in membrane permeate flux. Also, for the rapid mixing process, in-line mixer type was more efficient for organic removal than back mixer type. Therefore, it may be concluded that coagulation-UF hybrid membrane process comparing to UF alone process showed not only higher removal efficiency of organic matter, but also substantial improvement of permeate flux of UF membrane.

Effects of the Membrane Materials on the Filtration Characteristic in the Membrane Separation-activated Sludge Process (막 재질에 따른 막분리활성오니법의 여과 특성)

  • Kim, Hyung-Soo;Cho, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.42-49
    • /
    • 1998
  • By checking the variations of the raw water quality and MLSS, the effects of the membrane materials on permeable flux and quality of the treated water were investigated in this study. Due to the stability for high variations of MLSS, tubular type membranes were selected. Polysulfone group membranes and polyamide group membranes were tested. The crossflow operation mode was adapted, because membrane fouling problems could be easily controlled by adjusting the linear velocity. Due to the high concentration of the raw water, polyamide group membranes were originally expected to achieve two times higher permeable fluxes. However, difference was only approximately $20l/m^2{\cdot}h$ at $3kgf/cm^2$. It might be resulted from the high concentration of organic materials in the effluent of the RBC process. For the quality of the treated water, polyamide group membranes were slightly less effective. It might be resulted from the fact that polysulfone group membranes had more adsorptive capacities for the organic materials. The effects of temperature on the permeable flux were found to be significant. Despite of the irregular injection of raw water, the quality of the treated water was kept stable.

  • PDF

Effect of Dry Deposition on Water Quality -The comparison of several methodologies for estimating dry deposition flux (수질에 대한 대기건식침적의 영향 - 건식침적량 추정 방법론의 비교를 중심으로)

  • Cheong, Jang-Pyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.159-168
    • /
    • 2008
  • A special field experiment has been carried out from March 2001 to June 2001 at the Changhowon in Kyunggi to investigate a better methodology for the estimation of dry deposition of pollutions applicable in Korea. In this study, dry deposition plate was used to measure of total and water soluble acidic mass fluxes, and CPRI(Coarse Particle Rotary Impactor), CI(Cascade Impactor) were also used to measure ambient concentrations in various particle size ranges. Sehmel-Hodgson model was used to estimate dry depostion velocity and Weibull probability distribution function was applied to get generalized particle size distribution for the size fractioned concentration data sampled by CPRI and CI. Atmospheric dry deposition fluxes of mass and ionic matters estimated by the various techniques(one-step, multi-step, equi-concentration, subdivision for only the coarse particle range, applying Weibull distribution function, etc.) were compared to flux data sampled by DDP. It was found out that the deposition fluxes estimation methodology calculated by the each particle size range devided by particle size distribution characteristics and the rapidly changed points of deposition velocity using Weibull probability distribution function was the most applicable.

Evaluation of FO membrane performance for each type of pre-treatment from WWTP secondary effluents (하수방류수의 전처리 조건별 FO막의 운전성능평가)

  • Jeong, Junwon;Kim, Jihoon;Kim, Geonyoub;Park, Junyoung;Kim, Hyungsoo;Kim, Hyungsook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • The development of alternative water resources has emerged as an effective method for solving drought of water resources due to extreme weather and increase in water consumption. Recently, in Korea, there has been active research on reverse osmosis desalination technology, wastewater reuse using forward osmosis membranes, and the forward osmosis(FO)-reverse osmosis(RO) hybrid process combining these two technologies. In this study, the basic performance of FO membranes manufactured by three domestic and international manufactures such as Microfilter Co., Ltd., Toray Chemical Korea Inc., and Hydration Technologies Inc., were investigated for wastewater reuse. In addition, as an experiment to select feed solution, the selected membranes were operated 48 consecutive hours using three secondary effluents pretreated by the UF membrane with a pore size of $0.1{\mu}m$ and auto strainer with pore sizes of $1{\mu}m$ and $100{\mu}m$ as feed solution. Although there was not much difference in the operating performance. Thus, the treated water using the $100{\mu}m$ auto strainer was selected as feed solution applied to the assessment.

A study about treatment for water treatment residual sludge using submerged membrane system (침지식 막여과 공정을 이용한 정수장 배출수 처리에 관한 연구)

  • Kim, Jun-Hyun;Lee, Ju-Hyung;Moon, Baek-Su;Kwak, Young-Ju;Jang, Jung Woo;Kim, Jinho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.181-193
    • /
    • 2014
  • Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.

A Development of Pulse Oximeter module for Measurement of $SpO_2$ (산소포화도 측정을 위한 모듈형 펄스 옥시메터 개발)

  • 이한욱;이주원;이종회;조원래;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.3
    • /
    • pp.575-583
    • /
    • 2000
  • Pulse oximetry is a well established non-invasive optical technique for monitoring the $SpO_2$ during anaesthesia, recovery and intensive care. Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. In the measurement of the hemoglobin oxygen saturation, conventional method has required the technique of filtering of remove the noise, and of complex signal processing algorithm. So much time have been required to signal processing. In this research, we separate AC signal and DC signal in the stage of signal detection. Therefore we simplify the calculation algorithm for $SpO_2$. The implemented system have the high performance such an accuracy and a processing time than the traditional method.

  • PDF

A Conceptual Zero-Discharge System for Water Quality Management of the Nak-Dong River (낙동강 수질관리 방안-하수분리 무방류시스템의 개념적 고찰)

  • Park, Hee-Kyung;Hyun, In-Hwan;Park, Chung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.40-49
    • /
    • 1997
  • From water management point of view, the industrialization that we have achieved in the last decades brought out two major changes: water shortage and water quality deterioration. They are getting the big obstacles we must overcome to continuously pursue industrialization for further development in the next century. Many plans using dams and advanced treatment methods have been developed for control of quantity and quality, respectively. In this paper, an alternative is conceptually reviewed which is much different from the plans in regard that the alternative looks at system itself. It is based on an interceptor system coupling with a concept of zero-discharge. This system allows no discharge of wastewaters from point-sources to waterbodies which are very sensitive in terms of water quality. In addition reuse of treated effluents is emphasized to a maximum extent. The application of the system to the Nak-Dong river basin indicated that an interceptor system will need from the middle reaches of the basin where industrialization gets heavier. Since wastewaters are not directly discharged to the river, water quality of the down stream will improve. Treated effluents will be able to be reused at a number of industrial complex which currently get water from the Nak-Dong river. This reuse will help alleviate water shortage. The biggest problem anticipated is cost for building and operating such system. A cost-sharing plan among the beneficiaries is considered. Further research is suggested focusing on detailed engineering and technical matters for potential implementation.

  • PDF