• Title/Summary/Keyword: 분광필터

Search Result 75, Processing Time 0.045 seconds

Image Restoration Considering Chromatic Aberration Problem of Multi-Spectral Filter Array Image (다중 분광 필터 배열 영상의 색수차 문제를 고려한 영상 복원 알고리즘)

  • Kwon, Ji Yong;Kang, Moon Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.123-131
    • /
    • 2016
  • To capture color and near-infrared images simultaneously, a multi-spectral filter array(MSFA) sensor is used. This is because an NIR band gives additional invisible information to human eyes to see subject under extremely low light level. However, because lenses have different refractive indices for different wavelengths, lenses may fail to focus widely different rays to the same convergence point. This is why a chromatic aberration(CA) problem occurs and images are degraded. In this paper, the image restoration algorithm for an MSFA image, which removes the CA problem, is presented. The obtained MSFA image is filtered by the estimated low-pass kernel to generate a base image. This base image is used to remove CA problem in multi-spectral(MS) images. By modeling the image degradation process and by using the least squares approach of the difference between the high-frequencies of the base and MS images, the desired high-resolution MS images are reconstructed. The experimental results show that the proposed algorithm performs well in estimating the high-quality MS images and reducing the chromatic aberration problem.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source (음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구)

  • Jang, Hansol;Kim, Gyeong Hun;Han, Ga-Hee;Cho, Jaedu;Kim, Chang-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Time-encoded near-infrared spectroscopy (NIRS) system is proposed, based on a near-infrared (NIR) swept laser source, for comparison to the conventional NIRS method using a detector-type spectrometer. The cavity of the NIR swept laser source consists of a semiconductor optical amplifier (SOA) with a gain region around 800 nm, and several fiber-optic components. To change the output wavelength in time using an applied electric radio-frequency signal, an acousto-optic tunable filter (AOTF) is introduced in the fiber ring cavity configuration. To demonstrate the feasibility of an NIR swept laser source for NIRS imaging, the spectroscopic comparison of two kinds of absorbance-measuring systems a detector-type spectrometer using a white light source, and a source-type spectrometer using an NIR swept laser is successfully performed with an NIR-absorbing dye.

A Method to Reduce Spectral Distortion in the IHS Pan-sharpening Using Mean Filtering (평균 필터링을 이용한 IHS 영상융합 기법에서 분광 왜곡 감소를 위한 방법)

  • Lee, Jongseok;Choi, Kangseok;Wiratama, Wahyu;Sim, Donggyu;Oh, Seoungjun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.06a
    • /
    • pp.91-94
    • /
    • 2017
  • 본 연구에서는 Component-Substitution (CS)기반 영상 융합 방법 중 가장 빠른 처리 속도를 보이는 IHS 기법의 분광 왜곡 현상을 해결하기 위하여 히스토그램을 통해 분광 왜곡 현상을 분석하고 평균 필터링을 통해 분광 왜곡 현상을 해결한다. 제안하는 방법의 성능 평가를 위하여 아리랑 3 호로 촬영한 서울 지역 위성 영상에 IHS 방법과 제안하는 방법을 적용하여 주관적으로 비교하고 객관적으로는 Q4, SAM, ERGAS 의 지표를 사용하여 비교한다. 주관적 비교 결과 제안하는 방법이 분광 왜곡을 감소시킴을 보이며, 객관적 비교 결과 IHS 기법 대비 향상된 Q4, SAM, ERGAS 을 보인다.

  • PDF

근접장 분광 분석기술의 최근 동향

  • NaRi, Ta-Ta
    • The Optical Journal
    • /
    • s.103
    • /
    • pp.62-70
    • /
    • 2006
  • 본고에서는 근접장 분광분석을 중심으로 측정원리나 개요를, 특히 다른 고공간분해측정 방법과 비교하면서 정리한 후 근접장광을 발생시키는 광학소자인 근접장 프로브와 근접장 분광측정을 하기 위한 시스템을 소개하겠다. 그리고 그 측정예로써 액정 등에 이용되고 있는 컬러 필터의 분석예 및 반도체 등의 제조과정에서 문제가 되는 매우 작은 유기계 이물의 측정예를 나타냈다.

  • PDF

Fabrication of the Fast Scanning Spectrophotometer Using Si-Photodiode Array (실리콘 광다이오드 어레이를 이용한 초고속 분광분석기 제작)

  • 정만호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.51-58
    • /
    • 1997
  • I배열형 광다이오드인 EG&G Reticon을 사용하여 측정시간이 약 10[ms]인 광측정용 초고속 분광광도계를 제작하였다. 핵심 부품인 배열형 광다이오드의 물리적 특성인 화소의 균일성, 선형성, 분광감응도를 측정하였다. 화소의 균일성과 선형성은 각각 0.5[%] 이내에서 일치하였으며, 분광감응도는 400[nm]에서 900[nm]까지 표준검출기를 사용하여 구하였다. 제작된 분광광도계는 2[nm]의 대역폭으로 측정이 가능하며 측정불확도는 2[%] 정도였다. 성능평가를 위해 미표준국의 표준기준물인 2009 didymium 필터와 수은 선광원을 측정한 결과 양호한 값을 얻었다.

  • PDF

A Study on the Improvement of Image Fusion Accuracy Using Smoothing Filter-based Replacement Method (SFR기법을 이용한 영상 융합의 정확도 향상에 관한 연구)

  • Yun Kong-Hyun
    • Spatial Information Research
    • /
    • v.14 no.1 s.36
    • /
    • pp.85-94
    • /
    • 2006
  • Image fusion techniques are widely used to integrate a lower spatial resolution multispectral image with a higher spatial resolution panchromatic image. However, the existing techniques either cannot avoid distorting the image spectral properties or involve complicated and time-consuming decomposition and reconstruction processing in the case of wavelet transform-based fusion. In this study a simple spectral preserve fusion technique: the Smoothing Filter-based Replacement(SFR) is proposed based on a simplified solar radiation and land surface reflection model. By using a ratio between a higher resolution image and its low pass filtered (with a smoothing filter) image, spatial details can be injected to a co-registered lower resolution multispectral image minimizing its spectral properties and contrast. The technique can be applied to improve spatial resolution for either colour composites or individual bands. The fidelity to spectral property and the spatial quality of SFM are convincingly demonstrated by an image fusion experiment using IKONOS panchromatic and multispectral images. The visual evaluation and statistical analysis compared with other image fusion techniques confirmed that SFR is a better fusion technique for preserving spectral information.

  • PDF

Concept Design of a K-GMT Fiber-fed Multi-Object Spectroscopy

  • Hong, Sungwook E.;Park, Changbom;Chung, Haeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.37.1-37.1
    • /
    • 2016
  • 2022년부터 가동되는 거대 마젤란 망원경(GMT)은 1시간 노출로 I 필터 24등급 이상의 어두운 천체도 관측할 수 있을 것으로 예상되며, 이 경우 10초 지름의 시계 안에 3천 개 이상의 관측 가능한 천체가 존재하게 된다. 따라서 GMT를 가장 효율적으로 사용하는 방법은 은하와 항성에 대한 광시야 분광 탐사를 수행하는 것이다. 이를 위해서는 한 번에 여러 곳에 존재하는 수천 개의 천체를 동시에 분광할 수 있는 광섬유 다천체 분광기기가 필요하지만, 현재까지 제안된 GMT의 1세대 기기 중에서는 이를 동시에 만족하는 기기가 없다. 본 발표에서는 가시광선 영역의 분광기 13대를 연결하여 2천 개의 천체를 동시에 분광하는 기기의 개념 설계를 제안하고, 현재 논의되고 있는 다른 다천체 분광기기 디자인과의 비교를 수행한다.

  • PDF