• Title/Summary/Keyword: 부하유량

Search Result 447, Processing Time 0.028 seconds

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Analysis of Domestic Water Consuming Pattern and Metered Water Use (생활용수 소비패턴 및 실사용량 분석)

  • Kim, Ju Hwan;Cho, Im Young;Park, Noh Heuk;Woo, Hyoung Min;Ahn, Hyo Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1310-1315
    • /
    • 2004
  • 용수수요 추정의 기본은 수도계획에 사용할 수 있는 실사용량에 대한 조사로 이에 대한 자료가 거의 없기 때문에 각 수도사업별로 제시되는 추정방법이 조금씩 상이하며, 추정방법의 진위를 가릴 수 없이 수요추정의 악순환을 초래하고 있는 실정이다. 기존 물사용량 예측은 급수량 기준의 도시 전체에 내한 평균 LPCD를 이용함에 따라 물사용 특성을 충분히 고려찬 수 없어 지역별 실제 물사용량과 큰 오차가 유발되었다. 그러므로 수도계획 및 설계에 사용할 수 있는 신뢰성 있는 설계인자를 도출하기가 불가능하여 물수요 관리정책 수립, 수도요금체계 조정 및 누수방지계획 수립 등 경제적인 수도시설의 건설에 애로를 겪고 있다. 본 연구에서는 생활용수 중 가정용수에 대하여 세탁기, 변기, 싱크대 등 수도전에 유량계를 설치 실제 가정에서 사용하고 있는 용도별 사용량을 실측, 파악하였으며, 이로부터 얻은 용도별 사용량에 대한 기간별 소비특성을 분석하였다. 이로부터 생활용수 사용량의 소비패턴 및 시간대별 부하율 산정이 가능하며, 각종 용도별 사용수량의 소비형태를 찾아낼 수 있었다. 또한 가정용수 중 용도별 물 사용비율은 세탁용수, 변기, 주방, 목욕용수의 순으로 나타났으며 주택유형별로는 아파트 연립주택, 다세대 주택, 단독주택의 순으로 단독주택에서의 물사용량이 가장 적게 나타났다. 생활용수 공급량에 내해서는 시간별, 주별, 월별 그리고 계절변동 총량을 파악하였으며 시간대별로는 오후 3시경이 최대 소비량을 보였고, 주별로는 월요일 그리고 월별로는 7월의 용수사용량이 가장 큰 것으로 조사 되었다. 본 연구로부터 도출된 용도별 실측 물사용량 자료 및 분석결과로부터, 지금까지 공급량 기준의 계획수립이 이루어져왔던 파종 수도시설 규모결정시 합리적인 용수수요예측 및 수요관리가 이루어질 수 있을 것으로 판단되며, 용수수요의 과다예측 오해 해소 등 경제적, 과학적 물관리 정책수립을 위한 기초자료를 제공할 수 있을 것으로 기대된다.는 경제적인 방법이 될 수 있다. 하천수 등의 상호 관계 분석을 통해 장기간의 유역 물순환체계 변화를 분석할 수 있었다.골풀과, 닭의장풀과가 각 1종씩으로, 조사지점( I )보다 좀 더 많은 종이 분포하는 것으로 조사되었다. 또한 어류는 조사지점( I )에서 3회에 걸쳐 총 396개체가 채집되어 3목 8과 21종이었다. 이 중 한국 고유종은 11종이었고, 외래 어종은 검정우럭과 2종이 조사되었으며, Zacco platypus(피라미), Zacco temmincki(갈겨니), Acheilongnathus koreanus(칼납자루), Odontobutis platycephala(동사리), Coreoleuciscus splendidus(쉬리) 순으로 분포하고 있었고, Acheilognathus signifer(묵납자루)는 댐 건설 전에는 많이 분포하였으나 현장조사에서 서식을 확인 할 수 언어 개체수의 큰 감소내지 멸종된 것으로 추정되었다.에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한 HSP 환자군에서도 $IL1RN^{*}2$ allele 빈도와 carriage rat

  • PDF

The State and Sources of Contamination with BOD, COD, T-N and T-P in Stream Within Chonju City (전주시 하천의 BOD, COD,총질소, 총인에 대한 수질현황 및 오염원)

  • 오창환;이지선;김강주;황갑수
    • Economic and Environmental Geology
    • /
    • v.35 no.1
    • /
    • pp.43-54
    • /
    • 2002
  • The Chonju and Samchun streams are palling though Chonju City and several contamination sources are located along these streams. The Samchun stream joins the Chonju stream in the Gosapyeong waste disposal site and the Chonju stream finally joint to the Mankyeong River. The Chonju and Samchun streams are now contaminated with BOD, COD, T-N and T-P and the amounts of each contamination are increasing from upper stream to downstream. At the downstream the amounts of COD. T-N.T-P are several times higher than fifth grade of water quality thor lacustrine. Sewage from Chonju provides BOD, COD,T-N and T-P into the Chonju and Samchun streams and Chonju Waste Water Treatment Plant il a main source of COD, T-N and T-P contamination. Gosapyeong waste disposal site may be the source of BOD and COD contamination. T-N is higher than fifth grade of water quality for lacustrine at the upper stream indicationg that the rivers are contaminated with T-N before inflowing into Chonju by agricultural activity. The Chonju stream asffects the contamination of the Mankyeong river with BOD. COD, T-N,T-P. Other branch steams of the Mankyeong river also affects the contamination of the Mankyeong river by BOD, COD, T-N and T-P, Among the branch streams, the Ikasn stream is a main contamination source. Amounts of concentrations inflowing from the Chonju and Sanchun Streams on Aug. 1999 are calculated by using yeasured flow rate find concentrations of contaminants The result are as fikkiws; 1) the amounts of influent from the Gosan Stream are 0.49, 0.86, 1.61 and 0.01 ton/day for BOD, COD, T-N and T-P, respectively, 2) compared to the amounts of influent from the Gosan Stream, BOD, COD,T-N,T-P supplied from the Chonju river are higher by about 5, 7, 7. 36 times, respectively, and those supplied from the Iksan stream are higher by about 13, 10, 10, 147 times, respectively.

Analysis of Monitoring Characteristics of Small Stream for TMDL (오염총량관리를 위한 소하천 모니터링 자료의 특성 분석)

  • Ha, Don-Woo;Park, Seung-Ho;Joo, Sungmin;Lee, Gi-Soon;Baek, Jong-Hun;Jung, Kang-Young;Lee, Youngjea;Kim, Kyunghyun;Kim, Young-Suk
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.503-513
    • /
    • 2018
  • In order to continuous watershed management and improve water quality at Yeong-san river system, we analyzed and evaluated data on the monitoring of small stream in city and county boundaries within the watershed. In-period monitoring is estimated to be more frequent in the second quarter than the first quarter, so it should be considered when evaluating the target water quality by setting the target water quality. A small stream in the Yeong-san river system has higher concentration in the downstream area than the upstream area. As a result of calculating the load of the measuring point, Y.b B3(Pungyeongjeongcheon) and Y.b E1(Sampocheon) were high. The result of correlation analysis by monitoring point in order to evaluate the correlation between BOD and T-P items, BOD was highly correlated with COD and TOC, and was affected by emission of pollutants related to organic matter. T-P was highly correlated with SS and COD, and was affected by rainfall. This study will provide basic data and direction for designing efficient and scientific method for water quality management by analyzing accumulated water quality data by conducting long-term monitoring.

Assessment of stream water quality and pollutant discharge loads affected by recycled irrigation in an agricultural watershed using HSPF and a multi-reservoir model (HSPF와 다중 저류지 모형을 이용한 농업지역 순환관개에 의한 하천 수질 및 배출부하 영향 분석)

  • Kyoung-Seok Lee;Dong Hoon Lee;Youngmi Ahn;Joo-Hyon Kang
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.297-305
    • /
    • 2023
  • The recycled irrigation is a type of irrigation that uses downstream water to fulfill irrigation demand in the upstream agricultural areas; the used irrigation water returns back to the downstream. The recycled irrigation is advantageous for securing irrigation water for plant growth, but the returned water typically contains high levels of nutrients due to excess nutrients inputs during the agricultural activities, potentially deteriorating stream water quality. Therefore, quantitative assessment on the effect of the recycled irrigation on the stream water quality is required to establish strategies for effective irrigation water supply and water quality management. For this purpose, a watershed model is generally used; however no functions to simulate the effects of the recycled irrigation are provided in the existing watershed models. In this study, we used multi-reservoir model coupled with the Hydrological Simulation Program-Fortran (HSPF) to estimate the effect of the recycled irrigation on the stream water quality. The study area was the Gwangok stream watershed, a subwatershed of Gyeseong stream watershed in Changnyeong county, Gyeongsangnam-do. The HSPF model was built, calibrated, and used to produce time series data of flow and water quality, which were used as hypothetical observation data to calibrate the multi-reservoir model. The calibrated multi-reservoir model was used for simulating the recycled irrigation. In the multi-reservoir model, the Gwangok watershed consisted of two subsystems, irrigation and the Gwangok stream, and the reactions (plant uptake, adsorption, desorption, and decay) within each subsystem, and fluxes of water and materials between the subsystems, were modeled. Using the developed model, three scenarios with different combinations of the operating conditions of the recycled irrigation were evaluated for their effects on the stream water quality.

Experimental Study on Energy Saving through FAN Airflow Control in the Generator Room of a 9200-ton Training Ship (9200톤급 실습선 발전기실 FAN 송풍유량 제어를 통한 선박에너지 절약에 관한 실험적 연구)

  • Moon-seok Choi;Chang-min Lee;Su-jeong Choe;Jae-jung Hur;Jae-Hyuk Choi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.697-703
    • /
    • 2023
  • As a part of the global industrial efforts to reduce environmental pollution owing to air pollution, regulations have been established by the International Maritime Organization (IMO). The IMO has implemented various regulations such as EEXI, EEDI, and CII to reduce air pollution emissions from ships. They are also promoting measures to decrease the power consumption in ships, aiming to conserve energy. Most of the power used in ships is consumed by electric motors. Among the motors installed on ships, the engine room blower that takes up a significant load, operates at a constant irrespective of demand. Therefore, energy savings can be expected through frequency control. In this study, we demonstrated the efficacy of energy savings by controlling the frequency of the electric motor of the generator blower that supplies combustion air to the generator's turbocharger. The system was modeled based on the output data of the turboharger outlet temperature in response to the blower frequency inpu. A PI control system was established to control the frequency with the target being the turbocharger outlet temperature. By maintaining the turbocharger design standard outlet temperature and controlling the blower frequency, we achieved an annual energy saving of 15,552kW in power consumption. The effectiveness of energy savings through frequency control of blower fans was verified during the summer (April to September) and winter (March to October) periods. Based on this, we achieved annual fuel cost savings of 6,091 thousand won and reduction of 8.5 tons of carbon dioxide, 2.4 kg of SOx, and 7.8 kg of NOx air pollutants on the training ship.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF