• Title/Summary/Keyword: 부하순환

Search Result 283, Processing Time 0.04 seconds

Application of SWMM for Reduction of Runoff and Pollutant Loading in LID Facilities (LID시설의 유출량 및 오염부하 저감효율평가를 위한 SWMM모델의 적용)

  • Jung, Kwang-Wook;Jung, Jong-Suk;Park, Jin-Sung;Hyun, Kyoung-Hak
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.249-256
    • /
    • 2017
  • Urbanization can be remarkable affected flood, pollutant loading, ecological system, and green infrastructure by distortion of hydrologic cycle. In order to mitigate these problems in urban, Low Impact Development(LID) technique has been introduced and applied in the world. SWMM model was calibrated with sets of field monitoring data and applied for calculation of runoff and pollutant loading in Asan-tangjung LID city under 2016 rainfall. Runoff reduction of watershed and catchment basins were showed efficiency 12.2% and 62.0%, respectively. Reduction of COD and TP loading also high efficiency in catchment basins were evaluated 74.9 and 71.4%. The results of this study can be used effectively in decision making processes of urban development project by comparing watershed runoff and pollutant reduction by designs of sort of LID technique, LID volume and location.

Ammonia removal rate on ammonia loading rates in seawater filtering system using rotating biological contactor (RBC) (회전원판을 이용한 해수 순환여과 시스템에서 암모니아 부하율에 따른 암모니아 제거율)

  • SON Maeng Hyun;JEON Im Gi;CHO Kee Chae;KIM Kang Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.4
    • /
    • pp.367-372
    • /
    • 2000
  • A series of experiment was conducted to investigate the relationship between ammoia removal rate and ammonia loading rates in seawater filtering system using rotating biological contactor (RBC). In this experiment, RBC system was consisted of rotating polyvinyl film disks, which provided $12 m^2$ of total effective surface area in $0.075 m^3$ of volume. $NH_4Cl$ was added by $10{\~}150 g$ as a ammonia nitrogen source to determine ammonia removal rate in RBC system. Relationship between time required for ammonia removal (y: hour) and nitrogen inputted ($x: NH_4-N mg/l$) in RBC system was as followed: $y=3.51+7.76 lnx (r^2=0.936)$. At ammonia concentration $2 mg/l$, it took 10 hour for removal of ammonia in the RBC system. However, at ammonia concentration of $5 and 16.5 mg/l$, it took 16 and 27 hours, respectively. There was a decreasing tencency of an increasing ammonia in the rearing water. Finally, the ammonia removal rate in the RBC system increased with the rise of total ammonia concentration up to $16.5 mg/l$.

  • PDF

Optimal Hydraulic Loading for Ammonia Control in Water Recycling Fish Culture System (순환여과식 양어장의 암모니아 제어를 위한 최적 수리학적 부하)

  • LEE Suk-Mo;KIM Do-Hee;SONG Kyo-Ouk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.3
    • /
    • pp.176-180
    • /
    • 1992
  • Nitrification Is an important facet of water recycling fish culture system, because the toxic cation ammonia is converted to the innocuous anion nitrate. This study was attempted to find the optimal design factor of submerged filter for ammonia removal in water recycling fish culture system. The experimental system was designed submerged filter with corrugated skylight plate, and operated in the fish farm, National Fisheries University of Pusan. When the influent ammonia concentration was about 10mg/l (9.43-13.66mg/l) nitrification rates were tested for the removal of ammonia over a four stage of the hydraulic loadings. The submerged filter removed 76.24, 62.88, 39.09 and $9.20\%$ of the ammonia to hydraulic load of 0.028, 0.037, 0.056 and $0.111m^3/m^2$. day, respectively. We can apply the above data to the material balance on the ammonia concentration in a fish reservoir, and conclude that the maximum allowable ammonia production was 1.52mg/min, and the optimal hydraulic loading was $0.047m^3/m^2$\;\cdot day$, in order to maintain the ammonia concentration below 10mg/l in the fish reservoir.

  • PDF

A Study on the Inflowing Pollution Load and Material Budgets in Hampyeong Bay (함평만의 유입오염부하량 및 물질수지에 관한 연구)

  • Kim, Jong-Gu;Jang, Hyo-Sang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • In this paper, an analysis of the inflowing pollution load of the rivers in Hampyeong bay showed the average organic matter pollution loads of BOD, COD, and TOC to be 79.7 kg-BOD/day, 144.06 kg-COD/day, and 93.0 kg-TOC/day, respectively. The inflowing organic matter pollution load was the heaviest in Sonbul dike, followed by Jupo bridge and Yangman complex. With regard to season, the load characteristics were outstanding in July, the rainy period in the summer. The average inflowing pollution loads of nutrients were 20.9 kg-DIN/day, 17.1 kg-DIP/day, 148 kg-TN/day, and 37.4 kg-TP/day A comparison of the inflowing nutrients loads for each river showed the load to be the heaviest in Yangman complex, followed by Baegok bridge and Jupo bridge. In the experiment on the material budgets of Hampyeong bridge conducted using a box model, the detention time of fresh water was found to be 52.4 days, with the bay displaying the characteristics of a so dissolved inorganic nitrogen (DIN) in the nutrients material budgets, ${\Delta}DIN$ values were found to be negative, indicating the tendency of consumption and open sea leak by photosynthesis to be higher than the nitrogen that flowed in. As for dissolved inorganic phosphorus (DIP), ${\Delta}DIP$ showed positive values, indicating a tendency for accumulation as the supply through organic matter decomposition, elution load of sediments, and inflowing load of the river turned out to be higher than the consumption by phytoplankton and outflow to open sea.

Water quality management by bio-purification of bivalve, Mytilus galloprovincialis, in Masan Bay (이매패의 생물정화 기작을 이용한 마산만의 수질개선방안)

  • Hong, Sok Jin;Eom, Ki Hyuk;Jang, Ju Hyung;Park, Jong Su;Kim, Dong Myung;Kwon, Jung No
    • Journal of Wetlands Research
    • /
    • v.9 no.2
    • /
    • pp.71-84
    • /
    • 2007
  • Masan Bay is a representative semi-closed bay acted as a sedimentation reservoir with a slow current velocity and a poor water circulation in Korea. The pollutants from terrestrial sources into the Masan Bay have apparently environmental pollution problems, such as eutrophication, red tied, and hypoxia. In this study, An ecological modeling work was performed to estimate the material circulation including the growth of bivalve in ecosystem. Furthermore, the effect of water purification was calculated by filter feeding bivalve to particulate organic matter just like COD and phytoplankton. And Water quality management strategy by bio-purification of bivalve is derived through selection of location, quantification of bivalve aquaculture farm. The results showed that the optimum location for bivalve farming is where phytoplankton accumulation by physical processes is maximized and the optimum density and area of bivalve are 35 individuals $m^{-3}$ and ca. 500 hectare, respectively. When assuming conditions for the optimum growth of bivalve, COD could decrease by up to 18% even without other reduction of pollution loads.

  • PDF

Development of the Control Algorithm for Counterpulsation between a Moving-actuator type Bi-Ventricular Assist Device (AnyHeart) and a Natural Heart (한국형 심실 보조 인공심장과 자연심장 간의 counterpulsation 제어 알고리즘의 개발)

  • Nam, Kyoung Won;Choi, Seong Wook;Chung, Jinhan;Kim, Wook Eun;Min, Byoung Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.33-38
    • /
    • 2002
  • A Ventricular Assist Device(YAD) is used to support the injured natural heart So. when considering a control algorithm for YAD. it is important to reduce a natural heart's load to enhance its recovery condition. To reduce natural heart's load, a counterpulsation algorithm is used commonly. In this study, we developed a counterpulsation control algorithm for moving-actuator type VAD and tested its usefulness using in vitro MOCK circulatory system. To notice a natural heart's Pumping status, electrocardiogram(ECG) signal was used and as a result of test. the counterpulsation effect between YAD and a natural heart was occurred and Automatic Control Mode Transition was occurred properly.

Recirculated Multicast Switch Based on Tandem Expanded Delta Network (Tandem Expanded 델타 네트워크에 기반한 재순환 멀티캐스트 스위치)

  • Seo, Kyung-Hee;Lee, Su-Mi;Kim, Sung-Chun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1B
    • /
    • pp.80-86
    • /
    • 2003
  • High speed networking applications like video-on-demand require the support of switches that can handle very high multicast loads. Switches studied in the past can support multicast loads of 25${\sim}$30% To overcome this limitation, Tandem Expanded Delta Network(TEDN) multicast switch was proposed to support more higher multicast load by 85${\sim}$90% without degradation in the performance But there is tremendous routing capacity that is not used in the series of routing network blocks. This paper presents modified TEDN multicast switches to save the excessive routing capacity. by recirculating packets in last routing network, we can achieve the acceptable packet loss ratio with the smaller number of routing network blocks. Extensive simulations show that our proposed switches have the acceptable packet loss ratio with reduced hardware cost.

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

Evaluating the Effect of Low Impact Development on Yeongsan River Stream (영산강 수계 저영향개발(LID)의 수질효과 평가)

  • Kim, Seok-Gyu;Kang, Jea-Hong;Park, Se-Hwan;Ko, Kwang-Yong;Ha, Don-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.457-457
    • /
    • 2011
  • 저영향개발(LID, Low Impact Development)은 물순환체계 개선을 위해 녹색 공간의 확보, 자연형 공간 조성, 자연상태의 수문순환 기능의 유지 기법 등을 활용한 개발 대상지에서의 강우유출 및 비점오염원의 영향을 최소화할 수 있는 새로운 방법이다. LID는 강우 유출수의 지하침투, 강우 종료시 증발산량의 확보, 강우 유출수의 재이용 등을 통한 강우 유출량을 최소화하는 것에 그 목적이 있다. LID 방법은 우수저류 공원, 생태저류지, 지붕층 저류공원, 보도 저류공간, 인공습지, 완충녹지대, 수목 보존지대, 지붕층 배수관, 강우 저장조, 투수성 포장, 토양 개량, 불투수층 최소화, 비점오염원 저감 등으로 효율성, 경제성, 유연성, 합리성, 토지 가치증대 등의 장점이 있다. 영산강 수계의 BOD 배출부하량이 점오염원(21,019kg/일)과 비점오염원(50,047kg/일)의 비율이 3:7 로 비점오염원 배출부하량이 훨씬 큰 상태이다. 특히, 광주광역시, 농업용 토지, 축산계 등의 비점오염원이 영산강 수질에 크게 영향을 미치고 있다. 따라서 본 연구에서는 비점오염원의 영향이 큰 영산강 수계를 대상으로 앞으로 이루어지는 개발계획을 분석하여 LID 기법을 적용하였을 때 영산강 수질에 미치는 영향을 모델링을 통해 예측하고자 한다. 수질개선에 어느 정도의 효과가 있는지 검증하기 위해 국내 실정에 맞고 QUAL2E 모델을 근간으로 WASP5 모형의 장점들을 접목시켜 Bottle BOD의 반응기작 및 조류의 생산에 의한 유기물 증가, 탈질화 반응 등 정체수역에서 일어날 수 있는 반응기작을 모의할 수 있도록 보완한 QUALKO2 모형을 이용하여 그 효과를 모의하고자 한다. 본 연구를 통해 LID 기법이 도시화에 영향을 얼마나 덜 주는지, 수계의 비점오염원 효과를 통해 물순환 체계의 개선이 어느 정도로 어루어지는지에 대한 효과를 검증을 할 수 있는 계기가 될 수 있을 것으로 판단된다.

  • PDF

Study on Sediments' Release for Water Characteristics in Agricultural Reservoirs (농업용저수지의 수질 특성에 따른 퇴적물의 용출 영향 연구)

  • Lee, Jin Kyung;Choi, Sun Hwa;Lee, Seung Heon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.499-499
    • /
    • 2016
  • 본 연구는 오염된 농업용 저수지에 대하여 수층에 따른 수질 변화 특성을 조사하고, 저수지 저부의 퇴적물에 대한 용출 실험을 통해 수층별 수질 특성이 퇴적물의 용출에 미치는 영향을 분석하고자 수행되었다. 연구 대상 저수지의 선정은 설치년도 1960년대를 기준으로 이전과 이후로 분류하였으며, 주요 오염원을 축산계와 생활계 오염원으로 분류하여 각 다른 특성을 가진 저수지를 선정하여 조사하였다. 내부 오염 부하량이 수체에 미치는 영향을 평가하기 위해 실시한 용출량 실험 결과, 호기 조건에서 축산계오염원 저수지의 T-P가 미미하게 용출이 일어난 것을 제외하고는 생활계, 축산계오염원 저수지에서 용출이 일어나지 않았다. 반면에 혐기 조건의 경우에는 생활계오염원 보다는 축산계오염원 저수지에서, 1960년대 이후 설치된 저수지에서 보다는 1960년대 이전에 설치된 저수지에서 용출이 크게 일어나는 것으로 조사 되었다. 혐기 조건에서 T-N의 경우 생활계오염원과 1960년대 이후 설치된 저수지에서는 용출이 일어나지 않았으나, 그 외의 항목에서는 모두 용출이 일어나는 것으로 분석되었다. 특히 혐기조건에서는 모든 연구대상 저수지에서 T-P의 용출이 크게 일어나는 것으로 조사되었는데, 이는 부영양화의 주요 영향인자로 작용할 수 있으므로 저수지 저부의 혐기조건이 형성되는 것을 제어?관리해야 할 필요성이 있다고 하겠다. 연구 저수지에 대한 현장 조사 결과, 가뭄의 영향으로 수위가 평년에 비해 상당히 낮았으며, 저수량의 부족으로 저수지 주변의 바닥이 드러나거나 유출이 없는 등의 특징을 보였다. 수심이 낮은 5~7월의 조사 시기에는 표층의 DO 농도가 높음에도 저층부의 DO 농도는 1.2~2.2 mg/L를 나타내 약혐기조건이 형성됨을 확인하였다. 또한 현장측정기(HYDROLAB_Quanta)를 이용한 DO측정시, 저층부 퇴적물의 재부유를 막기 위해 저층경계면에서 30~50cm 윗부분을 측정했다는 점에서 저층부 바닥면의 DO 농도가 더 낮을 수 있다고 추정할 수 있다. 이는 이 시기에 퇴적층에 존재하는 오염물질의 용출이 충분히 일어날 수 있으며, 이후 8~11월에 수계 내 환란 및 순환에 의해 오염물질이 수중으로 이동하게 되고, 수질을 악화시키는 원인으로 작용할 수 있음을 추론할 수 있다. 이와 같이 퇴적되어 있던 오염물질이 계속적으로 용출 및 순환을 해마다 반복한다면 해당 저수지는 장기간 수질 오염 저수지가 될 수밖에 없을 것이다. 따라서 이러한 내부오염부하가 크다고 판단되는 저수지에 대하여 오염퇴적물의 관리가 필요하다고 하겠다.

  • PDF