• Title/Summary/Keyword: 부피측정

Search Result 1,046, Processing Time 0.034 seconds

A study on the system automation of medium-vacuum standard (중진공 표준기 자동화에 관한 연구)

  • 홍승수;임인태;신용현;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.207-213
    • /
    • 2003
  • We have developed the hardware and software for automation of the national medium vacuum standard. The automation is necessary to control and monitor the complex system consists of several vacuum chambers, pumping systems, vacuum gauges, thermometers, and valves. By using the automation program, we have measured volume ratios of the system and performed calibration of a capacitance diaphragm gauge in order to evaluate the system.

Realization for Automatic Stock Cubic Measuring and Distributing Management Embedded System with 3D Ultrasonic Sensing (3D 초음파센싱 자동물류부피측정 및 분류관리 임베디드시스템 구현)

  • Lee, Eun-Eok;Ryu, Kwang-Rryol;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.285-288
    • /
    • 2007
  • A realization for automatic stock cubic measuring and distributing management embedded system with 3 dimensional ultrasonic sensing is presented in this paper. The height and width of cubic are measured by comparing the 3 values from 3 ultrasonic sensors with reference when an object is passing the conveyer and length is calculated by the passing time and velocity, compensate cubic values for error to vary with the environment temperature, and reduce the error by averaging the sensing data not to be right posture of object. The system enables to classify and load a packed stocks at the store and transportation practically based on the rectangular hexahedral objects.

  • PDF

헤테로다인 기법을 이용한 부피 간섭계

  • 김영진;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.165-165
    • /
    • 2004
  • 정밀한 3차원 좌표측정을 위한 삼차원좌표측정기(Coordinate Measuring Machine)는 광학 스케일이나 헤테로다인 레이저 간섭계를 이용해서 x, y, z 축의 좌표를 측정한다. 이 경우 측정 정밀도에 가장 큰 영향을 주는 요인은 아베 오차(Abbe's error)이다. 인공위성용 광학계를 비롯해서 첨단 산업부품에 이르기까지 현재의 3차원 좌표측정은, 높은 정밀도와 대영역 측정을 동시에 요구하는 추세이다. 대영역으로 갈수록 _아베 오차의 영향은 더 커지므로 보다 근본적인 해결책이 필요하다.(중략)

  • PDF

Reproducibility of non-invasive measurement for left ventricular contractility using gated myocardial SPECT (게이트 심근 SPECT를 이용한 비침습적 심실 수축력 측정방법의 재현성)

  • Kim, Kyeong-Min;Lee, Dong-Soo;Kim, Yu-Kyeong;Cheon, Gi-Jeong;Kim, Seok-Ki;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.152-160
    • /
    • 2001
  • Purpose: We tried to establish the reproducibility of the measurement of maximal elastance (Emax) and to compare the degree of the reproducibility of two estimation methods: single pressure-volume loop method and parameter optimization method. Materials and methods: In 47 patients (42 males and 5 females, $53{\pm}10$ years old) with suspected coronary artery disease (election fraction; 22-68%), gated Tc-99m MIBI myocardial SPECT and arterial tonometry were acquired. In 11 patients among these 47 patients, gated SPECT and tonometry were performed twice consecutively with patients in situ. Emax and void volume (Vo) were estimated using single pressure-volume loop method of Lee and parameter optimization method based on linear approximation of Yoshizawa. Correlation between the consecutive measurements by each method and correlation between the two estimation methods were compared. Results: Reproducibility of Emax (r=0.96) and Vo (r=0.99) by single pressure-volume method was better than the reproducibility of Emax (r=0.89) and Vo (r=0.64) by parameter optimization method. Correlations of Emax and Vo were fair between the two methods. The correlation of Emax (r=0.77) was better than that of Vo (r=0.55). Conclusion: Reproducibility of Emax measurement by single pressure-volume loop method using gated myocardial SPECT and arterial tonometry was excellent. Reproducibility by parameter optimization method was also fair but was less than that achieved by single pressure-volume method.

  • PDF

Study on the Free Volume in Polymer by Positron Annihilation Lifetime Spectroscopy (PALS) (양전자소멸 수명시간 측정을 통한 폴리머소재의 자유부피에 관한 연구)

  • Kim, Yongmin;Shin, Jungki;Kwon, Junhyun
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.489-493
    • /
    • 2012
  • Positron Annihilation Lifetime Spectroscopy is a non-destructive technique to study voids and defects in solids by the measurement of gammas from electron-positron annihilation. In this study, we measured the lifetime of CR, EPDM, NBR, all of which are widely used polymer in various fields. A conventional fast-fast coincidence system in KAERI(Korea Atomic Energy Research Institute) has been used to measure the lifetime spectra, Three lifetime components were analyzed from each lifetime spectra. According to Tao-Eldrup model equation, the size and fraction of free-volume were calculated. Mean radius and free volume fraction of CR, EPDM NBR are $0.1217nm^3$(1.9103%), $0.14780nm^3$(5.3147%), $0.1216nm^3$(2.6381%), respectively. Through these measurements, we identified the feasibility of the PAL system for polymer analysis.

Axioms underlying area of triangle and volume of triangular pyramid and Hilbert't third problem (삼각형의 넓이와 삼각뿔의 부피에 내재된 공리와 힐베르트의 세 번째 문제)

  • Do, Jonghoon
    • Journal of the Korean School Mathematics Society
    • /
    • v.18 no.4
    • /
    • pp.371-385
    • /
    • 2015
  • In this paper we investigate the axioms defining area and volume so that revisit area formula for triangle, volume formula for triangular pyramid, and related contents in school mathematics from the view point of axiomatic method and Hilbert's third problem.

Excess Molar Volumes and Enthalpies for 1,2-dichloropropane + 2-methoxyethanol at the Temperature 298.15K. (1,2-dichloropropane(l) - 2-methoxyethanoI(2)계의 과잉 몰 부피 및 과잉 몰 엔탈피의 측정)

  • Kim, Moon-Gab;Lee, Young-Sei
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.2
    • /
    • pp.193-198
    • /
    • 2001
  • 2성분계 혼합물(1,2-dichloropropane + 2-methoxyethanol)에 대해 과잉몰 부피(excess molar volumes) $V^E$ 및 과잉 몰엔탈피(excess molar enthalpies) $H^E$를 298.15K에서 측정하였다. 혼합물의 밀도측정은 digital vibrating tube densimeter를 이용하였고, 과잉 몰엔탈피는 isothermal flow microcalorimeter를 이용하였다. 측정한 과잉 몰부피는 전 조성 영역에서 양의 편차를 나타내었으며, 과잉 몰엔탈피는 S 자형용 보였다. 또한 얻어진 data는 Nelder- Mead의 simplex method를 이용하여 Redlich-Kister 다항식에 접합 (fitting)하였다.

  • PDF

The Influence of Volume Effect in 2D-array Ion Chamber on the Measurement of IMRT Dose Distribution (2차원 배열형 이온함의 부피효과가 세기조절방사선치료의 선량분포 측정에 미치는 영향)

  • Kim, Sung Joon;Lee, Seoung Jun;Park, In Kyu;Lee, Jeong Eun;Park, Shin Hyung;Seol, Ki Ho;Kim, Jae Chul
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • We evaluated the influence of volume effect on the measurement of IMRT dose distribution by comparing a 2D-array ion chamber and other dosimeters. Matrix phantom which is a 2D-array ion chamber having volume effect was compared with beam image system and film for the measurement of dose distribution. Five intensity-modulated radiation therapy plans were created using five fields in thevirtual phantom. The measured dose distribution was compared with the calculated one by radiation treatment planning system and analysis program. We evaluated the conformity of dose distribution by calculating correlation coefficients and gamma values. The highest error rate of 1.3% was associated with matrix phantom in which volume effect in small field sizes was substantial.

The Significance and Limitation of MR Volumetry: Comparison between Normal Adults and the Patients with Epilepsy and Hippocampal Sclerosis (MR 부피측정의 의의와 한계: 정상성인과 해마경화증 간질 환자의 비교)

  • 김홍대;장기현;한문희;김현집;이상건;이명철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.47-54
    • /
    • 2002
  • Purpose : Hippocampal atrophy is one of the characteristic pathologic findings of hippocampal sclerosis, for which MR imaging of the hippocampus is essential in the evaluation of hippocampal sclerosis. The purpose of this study is to present the normal MR volumetric data of the hippocampus in normal adult Korean and to compare those with MR volumetric data of hippocampus in patients with hippocampal s-clerosis, providing the diagnostic volume criteria of the hippocampal atrophy. Materials and methods : MR volumetry was performed in 30 normal adults and 28 patients with temporal lobe epilepsy whose final diagnosis was hippocampal sclerosis. The volumetric data were compared between sexes, right and left sides, and normal and abnormal hippocampus, and the volume criteria for the diagnosis of hippocampal atrophy was determined. Results : The mean $volumes({\pm}standard$ deviation) of normal Korean adult were $2.20{\pm}0.73\textrm{cm}^3$ (right) and $2.17{\pm}0.72\textrm{cm}^3$ (left) in male and $2.27{\pm}0.47{\;}\textrm{cm}^3$ (right) and $2.23{\pm}0.48\textrm{cm}^3$ (left) in female. The mean right-left differences were $0.14{\pm}0.11\textrm{cm}^3$ and $0.19{\pm}0.13\textrm{cm}^3$ in male and female, respectively. The MR volumetry showed no significant statistical differences between sexes and between right and left. The mean volume and standard deviation of the hippocampus in hippocampal sclerosis patients was $1.46{\pm}0.60{\;}\textrm{cm}^3$, and the right-left difference was $0.51{\pm}0.41\textrm{cm}^3$, In comparison of two volume distributions between normal adult group and hippocampal sclerosis patients group, the reasonable diagnostic volume criteria was $0.4{\;}\textrm{cm}^3$ as right-left volume difference, in which the sensitivity and specificity are 0.61 and 0.90. In all patients with right-left volume difference more than $0.4{\;}\textrm{cm}^3$, visual determination of unilateral hippocampal atrophy was possible. Conclusion : The MR-based hippocampal volumetry is a useful add-on of visual MR diagnosis, only when visual diagnosis of hippocampal sclerosis is difficult.

  • PDF