• Title/Summary/Keyword: 부착판

Search Result 454, Processing Time 0.029 seconds

Long-term stabilization of optical feedback of a resonant external cavity coupled semiconductor laser (공진형 외부 캐비티 부착 반도체 레이저의 광피드백 장기 안정화)

  • 신철호
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.2
    • /
    • pp.96-99
    • /
    • 1998
  • In this study, a novel long term stabilization method of optical feedback for the resonant cavity coupled semiconductor lasers is proposed, and its utility was shown experimentally. The proposed method is realized by using the pahse discriminator of optical feedback with high gain. The phase discriminating signal was obtained by the polarization spectroscopic technique using reflection light from the external reflector, which is a confocal Fabry-Perot cavity. Experimental result shows that stable control state can be maintained up to 20 hours. The period can be increased by reducing size of the system and/or fixing position stably of optical parts used, which were arranged on an optical table by using magnetic bases in this experiment. The proposed long-term stabilization method of optical feedack of a resonant external cavity coupled semiconductor laser is very useful for the field of high sensitivity measurement, and for the use in the laboratory level in particular.

  • PDF

Numerical Study for the Optimal Operation of Regenerative Catalytic Oxidation(RCO) (축열식 촉매 산화(RCO) 반응의 조업 최적화를 위한 전산 해석)

  • Jung, Yu-Jin;Hong, Sung-Gil;Lim, Ki-Hyuk;Kim, Jin-Uk;Kim, Min-Choul;Lee, Jae-Jeong;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.500-503
    • /
    • 2011
  • 본 논문에서는 RTO 반응기의 최적 조업 조건을 도출하고자 현재 조업 중인 RTO 반응기 촉매층의 압력분포, 유속분포, 유선장, 체류시간, 온도분포 등에 대하여 분석하였고 최적의 조업 조건을 도출하기 위한 전상유체해석을 수행하였다. 전산 해석 결과, 현재 조업중인 반응기 촉매층의 축열재로 인한 압력손실은 크지 않은 것으로 나타났으며, 세라믹 필터 이후 유속은2-3 m/s로 특별한 편류없이 비교적 안정적 유속분포룰 보이고 있었다. 그러나 기류분포를 좀 더 개선하려고 한다면 설비 내부에 플래넘과 촉매층 접속 구간 연장 등의 방법을 고려할 수 있을 것으로 판단된다. 그러나 기류안내판이나 다공판 부착 등의 방법은 큰 효과는 없을 것으로 나타났다.

  • PDF

Research on the Adhesion of Flexible Copper Clad Laminates According to Species of Polyimide (폴리이미드 종류에 따른 연성 동박 적층판의 부착력 연구)

  • Lee Jae Won;Kim Sang Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.2
    • /
    • pp.49-54
    • /
    • 2005
  • Flexible copper clad laminates (FCCL) fabricated by sputtering has advantages in fine pitch etching and dimensional accuracy than previous casting or laminating type FCCL, But its lower adhesion is inevitable technical challenge to solve for commercializing it. Chromium (Cr) which strongly reacts with O moiety was used as tie-coating layer in order to improve low adhesion between copper (Cu) and polyimide (PI). Sputtering raw polyimide (SRPI) and casting raw polyimide (CRPI) were used as substrates at this research. PI was pretreated by plasma before sputtering, and each sample was varied with RF power and Cr thickness on sputtering. Peel strength of the FCCL on SRPI was higher than that on CRPI. Adhesion had maximum value when 10 nm of Cr was deposited on SRPI by RF power of 50 W. It seems to be by the formation of Cu-Cr-O solid solution at the metal-PI interface.

A study on the boiling heat flux on high temperature surface by impinging water jet (衝突水噴流에 의한 高溫面의 沸騰熱流束에 관한 硏究)

  • Lee, Ki-Woo;Kim, Yoo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.1
    • /
    • pp.81-94
    • /
    • 1988
  • A series of experiments was performed in this study to investigate the boiling heat flux between an impinging water jet and a hot surface. Test variables were surface roughness, jet velocity, saturation temperature excess of surface, nozzle diameter and the gap distance between nozzle plate and the hot surface. In order to make the impinged cooling water a forced flow streaming a long the hot surface immediately after the initial impingement, the flat nozzle tip was extended to a circular flat plate having the same diameter as the hot surface. Utilizing the dimensionless parameter study on continuity, momentum and energy equations, 5 groups of variables involved in the nucleate boiling heat transfer were derived so that it is possible to estimate the increased heat flux by impinging water jet in a similar experimental work. For the case of saturated water being impinging onto a high temperature surface, an applicable correlation among dimensionless parameters describing the heat flux was found to be as follow.

방파제케슨에 사용하는 신형식 푸팅구조의 역학적 특성과 구조해석

  • 한국어항협회
    • 어항어장
    • /
    • s.2
    • /
    • pp.86-127
    • /
    • 1988
  • 버트리스 푸팅 케슨(Buttress footing caisson) 및 상형 푸팅 케슨의 역학특성을 해명하고 구조설계법을 검토할 목적으로 재하실험을 실시했다. 재하실험에는 배근의 제약등을 고려해서 실구조물의 1/4정도의 대형모형공시체를 사용해서 푸팅부를 중심으로 해석하기위해 푸팅에 선분포하중을 재하했다. 유한요소법에 따른 선형구조해석을 실시하여 변위, 단면력과 한계상황설계법에서의 산정식에서 얻어진 단면내력과를 비교하여 동설계법의 케슨구조물에 대한 적용성에 관하여 고찰했다. 이 보고로써 얻어진 주요한 결론은 아래와 같다. (1) 재하실험에 의하면 버트리스 푸팅공시체의 파괴형식은 버트리스부의 철근에 연한 부착할열파괴였다. 또 상형푸팅공시체에서는 푸팅부의 내면전단파괴였다. 양구조물을 설계할 때는 종래의 면외력만의 검토뿐아니라 면내력도 적절히 평가할 필요가 있다. (2) 양공시체 함께 푸팅 케슨본체와의 접합부 및 푸팅과 상자옆쪽의 벽과의 접합부에 변형이 일어나 종래의 판구조설계에서 가정하고 있는 판주변의 고정조건이 만족되지 않았다. 따라서 케슨구조물의 구조해석에서 구조전체계를 취급할 필요가 있고 부재단위에서는 단면력을 과대 또는 과소로 산정할 우려가 있다. (3) 철근강복시정도까지는 구조전체계를 모델화한 유한요소법에 의한 선형구조해석결과와 실험결과가 잘 일치했다. (4) 한계상태설계법에서의 굽음내력, 전단내력 및 구열폭의 산정식은 실험결과와 비교해서 어느쪽이나 안전측의 치를 부여했다.

  • PDF

Analysis of Steady and Unsteady Performance for 3-D Surface Effect Wing (3차원 표면효과익의 정상 및 비정상 성능해석)

  • Il-Ryong Park;Ho-Hwan Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.3
    • /
    • pp.14-25
    • /
    • 1998
  • This paper describes the numerical modelling for the steady and unsteady forces of 3-D wings flying near the free surface based on a potential based panel method. For the steady problem where a wing flies over the fixed float surface, steady lift and drag forces are calculated for wings with and without end-plates having different sections, angle of attacks, aspect patios and flying heights. These numerical results are compared with the wind tunnel test results. The unsteady problem is treated as a boundary value one where a wing flies over the described wavy surface. The unsteady lift force variations of a wing due to different wave lengths and heights are calculated at different flying heights.

  • PDF

Design Modification and Correlation Verification between Reattachment Flow of Dispersed Jet and Local Thinning of Feedwater Heater (충돌로 인해 분산된 2상 제트스팀의 재부착 현상과 국부 감육 상관관계 규명 및 설계개선에 관한 연구)

  • Kim, Hyung-Joon;Kim, Kyung-Hoon;Hwang, Kyeong-Mo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.483-495
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line-inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

Design and Analysis of PIFA with Frequency Operation (이중 주파수에서 동작하는 PIFA의 설계 분석)

  • Park, Jung-Ho;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.107-116
    • /
    • 2001
  • In this thesis, characteristics of compact PIFA are analyzed for operation in dual frequencies (dual-PIFA) as variety of parameters. The antenna is composed of two patches. These are operated in high frequency and low frequency. The dimension of experiential antenna is fixed for attaching at the handset. The variable parameters are dimension of small patch, length of shorting strip and dimension of folded conductor plate, the frequencies are 900 MHz and 1800 MHz. The compact antenna is implemented with 2-layer type, electric field intensities and radiation patterns are simulated. In order to analyze characteristics of a performance as variety of parameters, FDTD method is used.

  • PDF

Self Sensing Reinforcement Combined with Fiber-Optic Sensor and FRP Strip for Structural Reinforcement (구조물 보강용 FRP 판과 광섬유 센서가 결합된 자기감지 보강재)

  • Song, Se-Gi;Seo, Soo-Yeon;Kim, Kang Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.123-130
    • /
    • 2019
  • Recently, it is required to develop a monitoring technology that combines an FBG sensor as a means for continuously monitoring whether reinforcing effect of FRP is maintained on FRP reinforced structural members. However, most existing researches focus on the insertion of FBG sensors into bar-shaped FRPs, and there is insufficient study on the details strip-type FRPs combined with FBG sensors. Therefore, in this paper, it is studied to develop a reinforcement in which a FBG sensor is combined with a FRP strip. Especially, combination of FRP and FBG sensor. For this, a series of experiments were performed to find the adhesive strength of fiber-FRP-epoxy joints, the tensile strength of FBG sensor part with reflection-lattice, and the performance depending on the connection method of FRF and FBG sensor. As a result of the study, it was found that a minimum strength of $216.15N/mm^2$ is required for incorporating FBG sensors in FRP using epoxy. It is considered that the adhesion length of epoxy joints should be more than 50mm. When the FBG sensor is attached to the FRP strip as an epoxy, it is considered appropriate to use the complete attachment and the sensor non-attachment method.

STUDIES ON THE PROPAGATION OF ABALONE (전복의 증식에 관한 연구)

  • PYEN Choong-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.3 no.3
    • /
    • pp.177-186
    • /
    • 1970
  • The spawning of the abalone, Haliotis discus hannai, was induced In October 1969 by air ex-position for about 30 minutes. At temperatures of from 14.0 to $18.8^{\circ}C$, the youngest trochophore stage was reached within 22 hours after the egg was laid. The trochophore was transformed into the veliger stage within 34 hours after fertilization. For $7\~9$ days after oviposition the veliger floated in sea water and then settled to the bottom. The peristomal shell was secreted along the outer lip of the aperture of the larval shell, and the first respiratory pore appears at about 110 days after fertilization. The shell attained a length of 0.40 mm in 15 days, 1.39 mm in 49 days, 2.14 mm in 110 days, 5.20 mm in 170 days and 10.00 mm in 228 days respectively. Monthly growth rate of the shell length is expressed by the following equation :$L=0.9981\;e^{0.18659M}$ where L is shell length and M is time in month. The density of floating larvae in the culture tank was about 10 larvae per 100 co. The number of larvae attached to a polyethylene collector ($30\times20\;cm$) ranged from 10 to 600. Mortality of the settled larvae on the polyethylene collector was about $87.0\%$ during 170 days following settlement. The culture of Nauicula sp. was made with rough polyethylene collectors hung at three different depths, namely 5 cm, 45 cm and 85 cm. At each depth the highest cell concentration appeared after $15\~17$ days, and the numbers of cells are shown as follows: $$5\;cm\;34.3\times10^4\;Cells/cm^2$$ $$45\;cm\;27.2\times10^4\;Cells/cm^2$$ $$85\;cm\;26.3\times10^4\;Cells/cm^2$$ At temperatures of from 13.0 to $14.3^{\circ}C$, the distance travelled by the larvae (3.0 mm In shell length) averaged 11.36 mm for a Period of 30 days. Their locomation was relatively active between 6 p.m. and 9 p.m., and $52.2\%$ of them moved during this period. When the larvae (2.0 mm in shell length) were kept in water at $0\;to\;\~1.8^{\circ}C$, they moved 1.15cm between 4 p.m. and 8 p.m. and 0.10 cm between midnight and 8 a.m. The relationships between shell length and body weight of the abalone sampled from three different localities are shown as follows: Dolsan-do $W=0.2479\;L^{2.5721}$ Huksan-do $W=0.1001\;L^{3.1021}$ Pohang $W=0.9632\;L^{2.0611}$

  • PDF