• Title/Summary/Keyword: 부식 높이

Search Result 44, Processing Time 0.021 seconds

Experimental Study on GFRP Reinforcing Bars with Hollow Section (중공형 GFRP 보강근의 인장성능 실험연구)

  • You, Young-Jun;Park, Ki-Tae;Seo, Dong-Woo;Hwang, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Fiber-reinforced polymer (FRP) has been generally accepted by civil engineers as an alternative for steel reinforcing bars (rebar) due to its advantageous specific tensile strength and non-corrosiveness. Even though some glass fiber reinforced polymer (GFRP) rebars are available on a market, GFRP is still somewhat uncompetitive over steel rebar due to their high cost and relatively low elastic modulus, and brittle failure characteristic. If the price of component materials of GFRP rebar is not reduced, it would be another solution to increase the performance of each material to the highest degree. The tensile strength generally decreases with increasing diameter of FRP rebar. One of the reasons is that only fibers except for fibers in center resist the external force due to the lack of force transfer and the deformation of only outer fibers by gripping system. Eliminating fibers in the center, which do not play an aimed role fully, are helpful to reduce the price and finally FRP rebar would be optimized over the price. In this study, the effect of the hollow section in a cross-section of a GFRP rebar was investigated. A GFRP rebar with 19 mm diameter was selected and an analysis was performed for the tensile test results. Parameter was the ratio of hollow section over solid cross-section. Four kinds of hollow sections were planned. A total of 27 specimens, six specimens for each hollow section and three specimens with a solid cross-section were manufactured and tested. The change by the ratio of hollow section over solid cross-section was analyzed and an optimized cross-section design was proposed.

Development of Marking Robot by using Arc Welding for Shipbuilding (조선 적용을 위한 문자마킹 자동용접장치 개발)

  • Park, Chul-Sung;Park, Jin-Whi;Ryu, Young-Soo;Lee, Jeong-Soo
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.3-3
    • /
    • 2009
  • 선박의 건조과정에서 필수적으로 선체 외판에는 선박의 안전과 운항 및 정비 등에 필요한 정보를 나타내기 위해 다양한 종류의 마크 및 문자가 마킹되어진다. 하지만, 단순한 도장 작업만으로는 해상과 같은 부식 환경에서 마크 및 문자가 쉽게 지워지거나 손상되기 때문에 마크 및 문자를 용접 비드(welding bead)로 표시하거나 미리 절단된 강판(steel plate)을 수동으로 용접한 뒤 도장을 함으로써 마크 및 문자의 손상을 방지하고 있다. 이러한 문자마킹작업을 하기 위해서는 작업자가 수작업으로 기준선과 마크 및 문자의 위치를 먹줄 등을 이용하여 마킹을 하고, 해당 마크 및 문자의 템플렛(template)을 이용하여 펀칭을 실시한 후 수동으로 용접을 실시한다. 하지만, 수작업을 통한 선체외판 문자마킹 작업은 작업자의 기량에 따라 품질이 상이하여 품질 저하의 원인이 된다. 또한 대조립 및 탑재 단계에서 문자 마킹 작업시 수직자세의 용접을 요구함으로써 작업자가 안전사고에 노출되어 있으며, 선박의 각 단계별 주요 공정보다 작업시간이 길어져 전체 선박 건조공정을 지연시키는 문제점 등을 야기시킬 수 있다. 이러한 문제점들을 해결하기 위해 조선업계에서는 선체 외판의 마크 및 문자를 자동으로 용접할 수 있는 장치를 개발하기 위해 노력해왔으며, 몇몇 개발 사례가 보고되고 있다. 하지만, 그 실효성 부분에서는 아직까지 해결하지 못한 문제점들로 인해 현장 적용에는 어려움을 보이고 있다. 본 연구에서는 선박외판 문자 자동용접장치의 기능성뿐만 아니라 현업 적용성을 가장 우선적으로 고려하여 문자마킹장치(Marking Robot for Shipbuilding) 개발을 진행하였다. 우선, 적절한 용접 재료를 선정하기 위해서 솔리드 와이어(Solid Wire)와 플럭스 코어드 와이어(Flux Cored Wire)에 대한 비드온 용접(Bead-On Welding)을 아래보기자세와 수직자세에 대해서 실시하여 적절한 용접 조건을 설정하였다. 본 연구에서 개발된 문자마킹 자동용접장치는 3축으로 구성되어 있으며 각 축들을 분리할 수 있도록 개발하여 이동성을 향상시켰으며, 작업면과 용접토치간의 거리를 일정하게 유지시킬 수 있도록 용접전류 센서(Welding Current Sensor)를 이용하여 토치 높이(Wire Extension)를 제어함으로써 균일한 품질의 용접비드를 얻을 수 있었다. 또한 문자마킹 자동용접장치는 본체 구동부와 제어부(Touch Screen)가 쉽게 분리되고 장착이 가능한 구조로 개발되었으며, 용접시 각 용접자세별로 용접전압, 전류 그리고 용접속도 설정이 가능하여 아래보기 자세뿐만 아니라 어떠한 자세에서도 같은 모양의 비드형상을 가지는 문자마킹용접이 가능하도록 개발하였으며, 이는 실험과 현장적용을 통해 검증하였다.

  • PDF

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.

Heating Efficiency of Difference Heat Collection Methods for Greenhouse (유리온실의 태양열 집열방법별 집열효과)

  • 최영하;이재한;권준국;박동금;이한철
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.166-170
    • /
    • 2000
  • Three methods for heat collection, which were the flat solar collector, two fan with radiator, and square pipe method, were studied to sue efficiently solar energy in the three different glasshouses for two years. The flat plate solar collector method was made use of the commercial solar collector with collection area of 24$m^2$, the method of two fans with radiators collected solar energy at the top of the glasshouse. An thermal storage tank was constructed underneath in teach glasshouses. When an area of 1,000$m^2$ was heated to the minimum temperature of 9$^{\circ}C$, the decrease rate of heating fuel for the flat plate solar collector, the fan attached radiator and the square pipe methods were 7%, 19% and 28% respectively. The flat plate solar collector method, which could be heated approximately 40-50$m^2$, was currently used by most of the farmer. Under the condition, the decrease rate of annual heating fuel was 14% which was not better for an economic annual heating fuel. If the fan with radiator method was operated, the use of installation and maintenance were required. So, it could not be good economic efficiency of solar heating. The heating efficiency of the square pipe method was relatively better thant those of the flat plate solar collector or the fan attached radiator. Since the cost of materials and its installation of the use of square pipe method was lower than any other method. However, corrosion of the pipe, greater shade in the greenhouse and strength against the square pipe were problems that should be overcome in the square pipe method.

  • PDF