• 제목/요약/키워드: 부식피로파장

검색결과 2건 처리시간 0.017초

3.5% NaCl 수용액의 온도변화가 복합조직강의 부식피로파괴에 미치는 영향 (The Effects of 3.5% NaCl Aqueous Solution Temperature on the Corrosion Fatigue Fracture of Dual phase steel)

  • 오세욱;도영문;박수영;김재철;김광영
    • 한국해양공학회지
    • /
    • 제6권1호
    • /
    • pp.140-147
    • /
    • 1992
  • Corrsion fatigue test was performed under rotated bending in 3.5% NaCl aqueous solution having a temperature from 278.deg.K in order to investigate the effects of aqueous solution remperature on the corrosion fatigue fracture of raw material steel(SS41) and dual phase steel that was produced from SS41 by a series of heat treatment. Corrosion fatigue life decreases remarkably with increase in solution temperature or with decrease in stress level. The corrosion fatigue life and the crack propagation rate at 303.deg.K show the similar behaviors with those at 318.deg.K, which is assumed to be caused by concentration polarization phenamena. The number and the lengths of microcracks increase with increase in solution temperature, so they lead to the decrease in corrosion fatigue life.

  • PDF

적외선열화상을 이용한 원자력발전소 감육 배관의 결함 검출 (Defect Detection of the Wall Thinning Pipe of the Nuclear Power Plant Using Infrared Thermography)

  • 김경석;장호섭;홍동표;박찬주;나성원;김경수;정현철
    • 비파괴검사학회지
    • /
    • 제30권2호
    • /
    • pp.85-90
    • /
    • 2010
  • 절대온도(OK) 이상의 온도를 가지고 물체는 표면온도에 대응하는 적외선 파장대역에서 적외선 에너지를 방출하게 된다. 적외선열화상은 적외선 파장대역에 반응하는 검출기를 이용하여 검출된 적외선 량을 온도로 변환하고 사용자에게 적외선영상을 실시간으로 제공하는 비파괴검사 방법이다 원자력발전소의 배관은 부식, 피로 등으로 인해 두께가 얇아져 큰 사고로 이어질 수 있는 결함이 발생하므로 이를 위한 효율적인 비파괴검사 시스템이 요구되고 있다. 따라서 본 연구에서는 적외선열화상 카메라로 측정한 온도와 배관의 결함 깊이 및 크기와의 상관관계를 알아보고 이를 원자력발전소 배관에 적용하여 결함을 검출하는 연구를 수행하였다.