• Title/Summary/Keyword: 부식도 지표

Search Result 53, Processing Time 0.027 seconds

Evaluation of Maturity Index for Garbage Composting Using the Sawdust as Bulking Agent (톱밥을 공극개량제로 사용한 음식쓰레기 퇴비화시 숙성도 지표의 적합성 평가)

  • Namkoong, Wan;Park, Sang-Hoo;In, Byung-Hoon;Park, Joon-Seok;Lee, Noh-Sup
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.3
    • /
    • pp.73-80
    • /
    • 2000
  • The objective of study was to evaluate the apropriate maturity indices for garbage composting using sawdust as bulking agent. Materials used in this study were the average composition garbage(G20) and garbage conditioned by sawdust(GS30, GS50) and cereals(GSC30). Indices for evaluating maturity were VS, water soluble TOC, polysaccharide, Humification Index(HI), and E4/E6. Experiment results showed that VS reduction was the most desirable index for evaluating compost maturity except for the GS50 which were conditioned with high sawdust Water soluble TOC decreased rapidly during the composting of first one month and then little changed. Therefore, water soluble TOC was recommended as maturity index. Polysaccharide was considered as a maturity index in case of garbage conditioned with sawdust and high cereals. Humification Index(HI) and E4/E6 were available as maturity indices in case of only some garbage composting so additional study was needed to confirm them as maturity indices for all garbage composting. Correlation analysis indicated that indices for evaluating maturity of garbage(about 30 C/N ratio) adding sawdust as bulking agent and high cereals, were VS reduction, water soluble TOC, polysaccharide, and E4/E6.

  • PDF

A Preliminary Study on the Reused Channel-Type Lining Board with Corrosion-Damage (부식 강재 복공판의 재사용성 평가에 관한 기초적 연구)

  • Kim, In-Tae;Kim, Dong-Woo;Choi, Hyoung-Suk;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.170-179
    • /
    • 2009
  • Channel-type lining board(CLB) is a welded steel structure used in the field of open cut subway excavation and building basement construction. Lining board is generally installed at the underground environment which is exposed to corrosion factors such as humidity, temperature and corrosive gases. This study evaluates reusability of the corroded lining board by experimental and analytical method. Static loading tests were performed to know serviceability of corroded CLB after checking thickness loss of the used CLB parts. Strain of the plates and middle point deflection was measured simultaneously. According to experimental test results and comparison with numerical analysis, the thickness loss of the plates by corrosion makes more vertical displacements and stresses in members under the DB vehicle load considering impact factor. As a result, this paper is proposed a way to evaluate used and corroded CLB by checking the plates thickness and it makes construction engineers easy to know optimal time to replace their old CLBs with new one.

Ranking Decision in River Management Class Adjustments: Methodology (하천관리등급조정의 우선순위결정: 방법론)

  • Kang, Min-Goo;Kang, Boo-Sik;Lee, Joo-Heon;Park, Doo-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1754-1758
    • /
    • 2009
  • 본 연구에서는 개정된 하천법에 의거하여 지방하천들 중에서 국가하천으로 지정하기에 적합한 하천들을 선별하여 이들의 관리등급을 조정하기 위한 방법론을 개발하였다. 대상 하천들 사이의 관리등급조정에 대한 우선순위를 결정하기 위하여 다기준의사결정법을 적용하였다. 개발된 하천평가지수에서는 세부기준을 하천중요도, 하천관리상태, 하천관리능력으로 구분하였으며, 지형 및 수문학적, 사회 및 경제적, 환경적 측면에서 각 세부기준들을 평가할 수 있는 지표들을 선정하였다. 또한, 수자원 분야 전문가들을 대상으로 설문조사를 실시하고 계층적 분석기법을 사용하여 평가기준들과 평가지표들의 상대적 중요도를 결정하였다. 국가하천지정 우선순위는 대상하천의 등급을 8개로 구분하고 각 등급 내에서 하천평가지수의 상대적 크기를 비교하여 결정하였다.

  • PDF

Development of Risk Prediction Index in Water Distribution System (상수관로 위험도 예측을 위한 평가 지표 개발)

  • Ye Ji Choi;Han Na Jung;Dong Woo Jang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.402-402
    • /
    • 2023
  • 상수관망은 충분한 양질의 수돗물을 공급하기 위한 사회기반 시설물이다. 상수관로의 노후화, 누수 등은 수도 사고 발생의 가능성을 증가시키고, 수돗물 안전성에 대한 신뢰도를 감소시킨다. 수돗물 공급 전 과정을 인공지능(AI), 정보통신기술(ICT)과 결합한 지능형 상수도관 예측 및 관리 시스템을 구축하여, 상수도 수질 사고를 조기에 감지하고 사전에 취약지점을 예측할 필요가 있다. 이를 위해서는 상수관로의 위험도를 평가하기 위한 체계적인 데이터와 기준이 필요하다. 본 연구에서는 상수관로의 위험도 예측모델을 개발하기 위해 상수관로 위험도와 관련된 평가 인자를 선정하고 분류하였으며, 각 인자의 명확한 기준을 제시하였다. 국내·외 상수도 위험도 평가 항목에 대한 자료를 비교 및 분석하였고, 전문가 자문을 통해 인자를 정립하여 상수관로 위험도 평가 지표를 개발하였다. 개발된 평가 지표의 현장 적용성과 실효성 검증을 위해 정량적인 데이터 확보가 가능하고 상태를 평가할 수 있는 대상 지역을 선정하였다. 문헌 자료의 평가항목들과 전문가 의견을 바탕으로 상수관로 위험도 평가 인자를 31개의 직접 인자와 5개의 간접 인자로 구분하였고, 인자별 평가 기준을 제시하였다. 직접 인자는 노후화 정도를 파악할 수 있는 노후도 평가 항목, 지역 특성을 반영한 토양 부식성 항목, 실시간으로 측정하여 결과를 제공하는 실시간 계측 항목, 직접적인 수질 결과를 제공하는 정수장 수질 항목, 상수관로의 건전성을 평가하는 자산관리 항목으로 분류하였다. 추후, 위험도 평가 운용을 위한 알고리즘을 개발하면 상수도 사고 위험에 대한 예방 및 대응 전략을 수립할 수 있을 것으로 기대된다.

  • PDF

Comparison of Surface Fuel and Soil Layer Moisture after Rainfall in Broad-Leaved Forest at Young Dong Region (영동지역 활엽수림에서의 강우 후 지표연료의 습도변화 분석)

  • Kwon, Chun-Geun;Lee, Si-Young;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.49-60
    • /
    • 2012
  • The change in fuel moisture in accordance with the number of days after rainfall is an important factor in predicting forest fire dangers and supporting forest fire rangers. Therefore, in order to clear up these forest fire occurrence conditions, forest fire danger levels for surface fuel 0.6 cm or lower, 0.6~3.0 cm, 3.0~6.0 cm, and 6.0 cm or above by fallen leaves layer, humus layer, soil layer, and diameter after rainfall of 5.0 mm and higher in accordance with tree density in 2008, 2009 Spring/Autumn Young Dong region have been analyzed. Research showed an approximate 17 % fuel moisture which is a dangerous forest fire occurrence level after 5 days from rainfall in medium-density areas and 3 days after rainfall in loose-density areas of Spring time in the fallen leaves layer. On the other hand, the humus layer showed a 40 % or higher fuel humidity even after 6 days from rainfall regardless of the season, while the upper and lower parts of the soil layer had a little change. In loose-density areas with 0.6 cm or less surface fuel per diameter in Spring time, the fuel humidity displayed a dangerous level in fire forest occurrence after 3 days, and 4days in medium-density areas, and for loose-density areas with 0.6~3.0 cm surface fuel per diameter in Autumn time it showed a dangerous level in forest fire occurrence after 3 days, and for medium-density areas, 5 days. In the case of 3.0~6.0 cm of fuel moisture per diameter in both Spring and Autumn times, even after 6 days, low and medium-density areas showed that they maintain fuel moisture and therefore the dangers of forest fires were very low, and in the case of 6.0 cm or higher, it showed 25 % or higher fuel moisture even after 6 days from rainfall regardless of the season.

Influence of Humic or Fulvic Acid on Phytotoxicity of Bentazone (Bentazone의 약해(藥害)에 미치는 부식산(腐植酸) 및 훌브산(酸)의 영향(影響))

  • Han, Dae-Sung;Yang, Jae-E;Shin, Yong-Keon
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.2
    • /
    • pp.162-168
    • /
    • 1993
  • This research was conducted to assess the influence of humic or fulvic acid on Bentazone phytotoxicity using a bioassay with hydroponically grown cabbage (Brassica campestris subsp. napus var. pekinensis Makino). Concentrations of Bentazone in the water culture media were ranged from 0 to 32 ${\mu}M $ and those of the organic ligands were 1.0mM as a soluble carbon. Media were prepared in a complete factorial combination with pHs of 4.5, 6.5 and 8.5. The phytotoxicity indices on growth rate and dry weight decrement were employed to evaluate the effects of organic ligands on the Bentazone phytotoxicity. Humic or fulvic acid without Bentazone treatment enhanced the growth of cabbage and this effect was evident at low pH of 4.5. Bentazone led to chlorosis and necrosis on cabbage leaves resulting in the decreases of dry and fresh weights and growth rate. This phytotoxic effect was increased with Bentazone concentration and evident at low pH. At pH 4.5, dry weight was decreased about 63% with 8${\mu}$M of Bentazone treatment. Effective concentration of Bentazone causing 50% decreases in fresh weight as compared to the control was estimated to be 21${\mu}$M. Presence of organic ligand reduced the phytotoxicity of Bentazone to cabbage significantly by increasing yields and growth rates as compared to the treatment of Bentazone alone. At pH 4.5, fulvic acid reduced phytotoxicity of Bentazone upto 46%, and this efficiency of fulvic acid was better than that of humic acid under the same condition.

  • PDF

Technical Application and Analysis for Reduction of Water Loss in Water Distribution Systems (상수도 관망의 유수율 제고 기술의 적용 및 분석)

  • Kim, Ju-Hwan;Lee, Doo-Jin;Bae, Cheol-Ho;Woo, Hyung-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.260-266
    • /
    • 2009
  • Non-revenue water reduction(NRW) technologies are implemented to evaluate and manage leakages scientifically in water distribution systems under local governments. A development of quantitative leakage indicator by measuring minimum night flow, pressure control policy by installation of PRV(pressure reducing valve) and the establishment of leakage prevention schemes by residual life modeling of deteriorated water pipes are reviewed and studied. Estimation models of allowable leakage are developed by measuring and analyzing minimum night flow at residential and commercial area in Nonsan city, which is suggested from UK water industry and can improve an existing leakage indicator for the evaluation of non-revenue water. Also, pressure control method is applied and analyzed to Uti distribution area in Sacheon city in the operation aspect. As results, $466\;m^3/day$ of leakage can be reduced and it is expected that 113million won of annual cost can be saved. In the part of corrosion velocity and residual life assessment, non-linear prediction models of residual thickness are proposed by assessment of corrosion velocity based on exposure years, soil and water quality etc., since the deteriorated water pipe play a major role to increase leakage. It is expected that collection data and analyzing results can be applied effectively and positively to reduce non-revenue water by accumulating surveying data and verifying the results in the business field of water distribution systems under local governments.

  • PDF

Development of CCPP(Calcium Carbonate Precipitation Potential) calculating program for corrosion control of drinking water distribution system (상수도관 부식방지를 위한 CCPP(Calcium Carbonate Precipitation Potential) 산정 프로그램 개발)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.170-175
    • /
    • 2008
  • In this study, we developed the CCPP calculating program, which is a kind of index and can determine whether calcium carbonate would precipitate or not in pipe line of water distribution system. Through 9 complicated procedures, CCPP can be calculated. Assuming pH of equilibrium as a first trial, compare the right-hand-side result with left-hand-side result. If the percentage difference between the two results is less than a prescribed tolerance, the initial assumption for the assumed equilibrium pH is adequate. If the difference is too large, make a different assumption and repeat until a result within the prescribed tolerance is achieved. Plugging the intermediate results into the final equation, we could compute the CCPP. Using Fortran and Visual Basic languages, we developed the program. As a result of application of the program, the water quality of intaking water of Han River is highly corrosive by the index of CCPP.

Measurement and Assessment of Alpha Activity in Ground Air (지표공기중(地表空氣中)의 ${\alpha}$ 방사능측정(放射能測定) 및 해석(解析))

  • Jun, Jae-Shik;Myung, Dong-Bun
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.130-138
    • /
    • 1986
  • A study on the measurement of alpha activity in ground air has been carried out using CA 80-15 and LR 115-1 cellulose nitrate nuclear track detectors. The detection efficiency of the detectors were determined by making use of an $^{241}Am$ alpha source of $0.1{\mu}Ci$ in activity under a known geometrical arrangement. For the field measurement of alpha activity of emanated radon and its progeny in ground air two different radon cups were installed for a certain period of time in two neighbouring ground holes of about 15 cm in diameter and 45 cm in depth. Of the two radon cups one kept closed space during the detecting period, while the other kept open space with a hole enabling the air to ventilate. The etched tracks were read out by a microscope and the results obtained through statistical analysis were evaluated in terms of alpha activity per unit volume of air.

  • PDF

The Study on Experimental Method of Smoldering Ground Fire in Forest Fire (뒷불 특성에 관한 실험방법 연구)

  • Kim, Dong-Hyun;Kim, Jang-Hwan;Kim, Eung-Sik
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.1-6
    • /
    • 2010
  • A smoldering ground fire can be a probable cause of reignition of surface fire when transmitted from Fermentation layer to Humus layer with temperature higher than that of ignition. Purpose of this paper is to identify experimental methodology on the potential risk of a smoldering ground fire, which is similar to the real surface fuel bed, and its combustion characteristics. The fuel model designed in this study is composed of 3 layers such as Litter layer, Fermentation layer and Humus layer and 8 Thermocouples are set through 3 layer at each boundary and in between to detect the temperature change and duration of smoldering and propagation velocity. As a result, it was observed that ignition conditions in the boundary between L layer and F layer determined transmission and non-transmisstion to F-H layer. In addition, range of critical humidity at which a smoldering ground fire was transmitted in a material layer was 33~44% and when temperature exceeds $350^{\circ}C$, likelihood of transmission of a smoldering ground fire was high. In the research, the experimental model for multi-layer smoldering ground fire is suggested and information about propagation of smoldering fire, possibility of reignition according to moisture content, propagation velocity and temperature change are obtained, Also, the built-up methods were established to help analyze basic characteristics of smoldering ground fire.