• 제목/요약/키워드: 부분방전시험

검색결과 76건 처리시간 0.03초

전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가 (Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line)

  • 김석수;최익순;박춘현;조이곤;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

위성 자세제어용 RLG 전류 안정화 회로 설계 (DESIGN OF THE RLG CURRENT STABILIZER CIRCUIT FOR ATTITUDE CONTROL IN THE SATELLITE)

  • 김의찬;최재동
    • Journal of Astronomy and Space Sciences
    • /
    • 제23권2호
    • /
    • pp.161-166
    • /
    • 2006
  • 이 논문에서는 위성 자세제어용으로 사용되는 RLG(Ring Lager Gyroscope) 전류 안정화 회로에 대해서 설명한다. RLG는 헬륨-네온레이저의 공진기 내에서 샤냑효과를 이용한다. 두 방전전류의 차이는 자이로 바이어스 오차의 한 부분을 차지한다. 전류 안정화회로의 이론적 배경과 설계과정에 대해서 기술하고, 입력전압 시험, 온도시험을 통하여 검증하였다.

철도차량용 견인전동기의 절연진단기술현황 (Present Status of Insulation Diagoniosis Technology on Traction Motor for Rolling Stock)

  • 왕종배;최규형;박현준;김명룡;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.370-372
    • /
    • 1997
  • 본 논문에서는 철도차량용 견인전동기의 열적, 기계적, 전기적 열화 및 환경열화 등의 절연열화 메카니즘에 대해서 검토하였으며, 전동기 주절연물의 전반적인 열화경향 파악과 국부적열화 검출을 위해 현재 적용되고 있는 절연저항, $tan{\delta}$, 직류성분, 정전용량 판정 및 부분방전 시험 등의 각종 절연진단 시험법과 최종적인 교류전압파괴 강도와의 상관성을 추정하는 진단기술의 현황과 그 유용성을 소개한다.

  • PDF

유전체 장벽방전 플라즈마 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균성능에 대한 실험 (Experiment on the Sterilization Performance of Airborne Bacteria in Indoor Spaces using the Variation of Ozone Concentration Generated According to the Discharge Time of a Plasma Module with a Dielectric Barrier Discharge Technology)

  • 이수연;김창수;김규리;임종언
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.344-351
    • /
    • 2023
  • 연구목적: 본 연구는 미생물의 비열 멸균 기술로서 실내 공간 내 유전체 장벽 방전 플라즈마 모듈의 방전시간에 따른 오존 발생 농도변화의 값을 통한 실내 공간 내 부유세균 살균 성능을 분석하였다. 연구방법: 76m3체적 공간의 공조장치의 공기배출 부분에 DBD 플라즈마 모듈을 설치하고 2m 떨어진 거리에서 DBD 플라즈마 처리 시간에 따라 공기 시료를 포집하여 미처리 대조군과 비교하여 부유세균 저감 효과를 분석하였다. 또한 DBD 플라즈마 방전에 따른 오존발생농도를 확인하였다. 연구결과: 대조군의 총 세균수는 1.83~2.00 logCFU/m3의 결과가 나왔으며, 시험군이 대조군에 비해 실내공기 중 부유세균의 최소 92.057%에서 최대 99.999%의 저감 효과를 보였다. 또한 평균 오존발생농도 0.04ppm으로 오존 발생농도 기준인 0.05ppm보다 낮은 결과를 확인하였다. 결론: 인체에 무해한 오존량과 DBD방전 플라즈마량을 조절함으로써 공기 중 부유세균, 바이러스등의 감염병 전파 방지의 수단으로 플라즈마 방전을 사용함에 기준이 될 것으로 사료된다.

소형위성 ETB에서의 전력계 기능시험

  • 윤영수;박종오;최종연;권재욱;안재철;조승원;김영윤
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2003년도 한국우주과학회보 제12권2호
    • /
    • pp.91-91
    • /
    • 2003
  • 위성을 발사하기 전까지는 지상에서 EGSE(Electrical Ground Support Equipment)를 이용하여 충분한 시스템 단위의 위성체 기능 시험을 수행한다. KOMPSAT-2(Korea Multi-Purpose Satellite - 2)와 같은 소형 위성의 서브시스템 각각이 요구사항에서 제시하는 규격을 만족하는지 여부를 점검하는 단계에서 전력계 관련 서브시스템의 기능 시험도 EPS(Electrical Power Subsystem) Test Plan에 의해 순차적으로 수행한다. KOMPSAT-2 ETB(Engineering Test Bed)에서의 전력계 시험은 먼저 Test Fuse Modules Check를 수행하였다. 퓨즈 모듈은 PCU(Power Control Unit) 상에 설치되어 있는 장치로써 퓨즈 모듈의 입력과 출력 사이에 도통성 및 다른 출력과의 절연성을 검증한다. 다음으로 EGSE 중 PMTS(Power Monitor Test Set)와 PCU와의 직렬 인터페이스를 점검하는 PCU Interface Check를 수행하였다 시험절차서에 따라 PCU가 가지는 릴레이 스위치에 대하여 명령어를 보내어 릴레이의 동작 상태 및 출력 전압 등을 점검한다. 다음 단계에서는 DC Integration을 수행하여 ETB 하니스 중 전원 관련 라인을 점검하였다 PCU는 모든 위성체 하드웨어에 전력을 공급하는 장비로써 과전력으로부터 하드웨어를 보호하기 위하여 하니스를 연결하기 전에 우선적으로 시험한다. 다음으로는 ECU(EPS Control Unit)가 각각에 해당하는 하드웨어에 명령어를 보내어 전력계 전체적인 동작 상태 검증하는 EPS Hardware Command & Telemetry Checkout을 수행하였다. ECU는 전력계의 모든 하드웨어를 제어하고 그 상태를 모니터링하는 기능을 한다. PCU와의 인터페이스를 통하여 전력의 제어 및 분배에 관련되는 특성을 제어 및 모니터하며 DDC(Deploy Device Controller)는 ECU로부터 명령어를 받아서 arm 및 safe 상태에 대한 텔리 메트리 데이터를 제공한다 그리고, SAR(Solar Array Regulator)는 ECU로부터 Bypass Relay 및 ARM Relay에 관한 명령어를 받아 수행되며 그에 따른 텔리 메트리 데이터를 제공한다. 마지막으로 EPS 소프트웨어를 검증하는 EPS Software Verification을 수행하였다 전력계 소프트웨어의 설계의 검증 부분은 현재 설계 제작된 전력계 .소프트웨어의 동작 특성 이 위성 의 전체 운용개념과 연계하여 전력계 소프트웨어가 전력계 및 위성체의 요구조건을 만족시키는지를 확인하는데 있다. 전력계 운용 소프트웨어는 배터리의 충ㆍ방전을 효율적으로 관리해 3년의 임무 기간동안 위성체에 전력을 공급할 수 있도록 설계되어 있다

  • PDF

고압 전기설비 부분방전시험을 위한 노이즈 저감방안 (A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery)

  • 이영준;박광하;최형주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF

저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구 (A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices)

  • 길경석;송재용;문승보;차명수;황돈하;강동식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

시험소 부분방전 측정시스템(ERA)의 소급성검토 (Review of the tracebility of ERA PD measuring system in test laboratory)

  • 허종철;강영식;김위영;오창수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1969-1971
    • /
    • 2004
  • For evaluation of partial discharge performances of electrical power appratus such as Insulator, circuit breaker and transformer and so on, Partial discharge measuring system(ERA) consisted of PD detector including amplifier, coupling capacitor, PD calibrator and voltage divider are used PD measuring system is very important factor which affect the test result and show reliability of test result in test laboratory, In this paper, we describe tracebility and uncertainty of PD measuring system in test laboratory based on IEC 60270.

  • PDF

초고압 GIS용 부분방전 UHF 센서의 현장 성능시험 연구 (Research about a Field Test of PD UHF Sensor's Sensitivity for a High Voltage GIS)

  • 김정배;정재룡;김민수;송원표;김맹현;고회석;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1762-1765
    • /
    • 2004
  • This paper suggest the field test method of PD UHF sensor's sensitivity for a high voltage GIS and prove a reliability of the field test method through the test results of UHF sensor.

  • PDF

시험용 변압기 내 부분방전의 초음파 검출에 관한 연구 (Detection of Acoustic signals by PD in Test Transformer)

  • 곽희로;권동진;진상범;전상준;정용기;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1293-1295
    • /
    • 1995
  • This paper describes the detection of the ultrasonic signals reduced by barrier in test transformer. The ultrasonic signals are generated by partial discharges which cause the insulation failure of transformer. The ultrasonic signals are reduced by barrier. But it was shown that the reduced ultrasonic signals can be measured as the location of the ultrasonic signal detectors is selected properly.

  • PDF