• Title/Summary/Keyword: 봉합 나사못

Search Result 39, Processing Time 0.023 seconds

One Anchor Double Fixation (OADF) Technique for Arthroscopic Bony Bankart Repair (두가닥의 봉합사를 가진 봉합나사못을 이용한 새로운 관절경적 골성 방카르트 병변 봉합술)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Bae, Seung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the usefulness of arthroscopic Bony Bankart repair using a One Anchor Double Fixation Technique. Materials and Method: Seventeen patients with a Bony Bankart lesion were treated using the One Anchor Double Fixation Technique (OADF Technique). There were 13 males and 4 females. The average age was 24 years (range 17-42). The average follow-up period was 22.3 months. One 3.0 mm suture anchor with doubly loaded sutures was inserted into the glenoid rim. One suture strand was passed the around the small bony fragment and tied first. Another suture strand was passed through the capsule and tied over the bony fragment. The result was measured using Rowe's evaluation index & KSS score. The glenoid defect & bony fragment were measured by 3D-CT scan. Results: Rowe's evaluation index on the final follow-up showed an overall improvement from an average of 54 (range, 23-71) to 83.4 (range 71-90). Of the 17 cases, 13 were excellent, 3 were good, and 1 was fair. KSS scores showed improvement from an average of 71 (range 49-82) to 92.5 (range 82-94). There were no cases where pain continued to the final follow-up, and no cases being re-dislocated during the follow-up period. For six cases, we confirmed the bony healing of the bony Bankart lesion by CT. Conclusion: Bony Bankart lesion repair using this new method achieves excellent clinical results with low recurrence rates and is considered another choice for bony Bankart lesions.

Rupture of the ischial origin of the hamstring tendon - A case report - (좌골 결절부위 기시부에서 내측 슬괵건 파열 - 증례 보고 -)

  • Kim, Hyung Kan;Hwang, Sun Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.129-132
    • /
    • 2011
  • A complete rupture of hamstring tendon originated from ischial tuberosity is a uncommon sports injury in adults. We present successful outcome obtained by attachment on ischial tuberosity using suture anchor in relatively rare case of the proximal rupture of the medial hamstring tendon sustained during landing with the review of literatures.

  • PDF

The Modified Phemister Operation with the Suture Anchor Added for the Augmentation of Conoid Ligament in Acute Acromioclavicular Dislocation (견봉쇄골 관절의 급성 탈구에서 원추인대 기능의 강화를 위한 봉합 나사못을 추가한 변형된 Phemister 술식)

  • Moon, Gi-Hyuk;Nam, Il-Hyun;Lee, Yeong-Hyun;Kim, Ki-Choul;Lee, Jae-Hoon;Ahn, Gil-Yeong
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.34-39
    • /
    • 2010
  • Purpose: The purpose of this study was to present methods and results for the modified Phemister operation, with a suture anchor added for augmentation of the conoid ligament in cases of acute dislocation of the acromioclavicular joint. Materials and Methods: We evaluated 14 cases of acute dislocation of the acromioclavicular joint. This included 11 cases of Rockwood type 3, and 3 cases of type 5. The mean age of patients was 45.2 years. We operated on them using an anchor for augmentation of the conoid ligament in the modified Phemister operation. The average follow-up period was 14 months and post-operative clinical analysis was conducted using the Weitzman classification, VAS Score, Constant Score and KSS Score. Results: According to Weitzman scores, 13 cases were evaluated as excellent, and one case was good. They had mean joint ranges of forward elevation of $170.7^{\circ}$, lateral elevation of 166.4, external rotation of 68.2, and internal rotation to the level of T7. The mean VAS Score was 1.9, mean Constant Score 90.8, and the mean KSS Score 91. Radiologic analysis indicated that all cases had a good result. Conclusion: The modified Phemister operation with a suture anchor added for augmentation of the conoid ligament is very effective clinically in acute dislocations of the acromioclavicular joint.

Coracoclavicular Ligaments Reconstruction for Acromioclavicular Dislocation using Two Suture Anchors and Coracoacromial Ligament Transfer (견봉 쇄골 탈구의 봉합 나사못과 오구 견봉 인대 이전술을 이용한 오구 쇄골 인대 재건술)

  • Shin, Sang-Jin;Roh, Kwon-Jae;Jeong, Byoung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.46-52
    • /
    • 2008
  • Purpose: This study examined the outcomes of reconstruction of the coracoclavicular ligaments with using two suture anchors and performing coracoacromial ligament transfer in patients with acromioclavicular dislocation. Material and methods: Forty patients with complete acromioclavicular dislocation were included in this study. According to the preoperative radiographs, 5 patients with AC dislocations were diagnosed as type III, 4 patients as type IV and 31 patients as type V. Two 3.5mm suture anchors with four strands of nonabsorbable sutures were separately placed on the anterolateral and posteromedial portion of the base of the coracoid process to stabilize the distal clavicle. The coracoacromial ligament was then transferred to the undersurface of the distal end of the clavicle for augmentation. Results: At a mean follow-up of 28 months, the average Constant score improved to 97 points. All the patients returned to normal life at an average of 3.2 months postoperatively. At the last follow-up, 37 patients achieved anatomical reduction and three patients showed complete redislocation. However, the clinical results of the patients with redislocation were satisfactory. Conclusion: Anatomical coracoclavicular reconstruction using two suture anchors and coracoacromial ligament transfer for treating complete acromioclavicular dislocation is a safe, effective procedure for restoring a physiologically stable acromioclavicular joint.

The Surgical Treatment of Type V Acute Acromioclavicular Joint Dislocation Using Suture Anchor and Kirschner Wire (봉합 나사못과 Kirschner 강선을 이용한 제 5형 급성 견봉 쇄골 관절 탈구의 수술적 치료)

  • Jung, Gu-Hee;Cho, Chyul-Hyun;Jang, Su-Jin;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.217-222
    • /
    • 2010
  • Purpose: We wanted to evaluate the clinical outcomes after operative treatment using two suture anchors and Kirschner wire for treating acute Rockwood type V acromioclavicular joint dislocation Materials and Methods: Between May 2006 and May 2009, 10 patients underwent surgical treatment for acute Rockwood type V acromioclavicular joint dislocation using two suture anchors and Kirschner wire and they were followed for a mean of 12.0 (range: 7-31) months. We analyzed the functional results by the Korean shoulder score, the Constant-Murley score and the reduction state of the acromioclavicular joint at the last follow-up. Results: All the cases achieved a satisfactory outcome. The mean Korean shoulder score was 89.9 (range: 81-100) points and the mean Constant-Murley score was 87.8 (range: 82-93) points. According to the radiologic findings, 8 patients achieved anatomical reduction of the acromioclavicular joint: there was a slight loss of reduction in one patient and a partial loss of reduction in one patient. None of the patients had deep infection or re-dislocation. Conclusion: The operative treatment using two suture anchors and Kirschner wire may be used for acute Rockwood type V acromioclavicular joint dislocation, and it has an advantage in that it can prevent chondral injury of the joint.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Current Concept of Anterior Shoulder Instability Repair (견관절 전방 불안정성의 봉합술에 대한 최신 지견)

  • Kim, Young-Kyu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • 견관절 전방 불안정성의 관절경적 치료는 환자 개개인의 병리 상태를 잘 파악하여 적절한 복원술을 시행함으로써 보다 좋은 결과를 기대할 수 있다. 현재 관절경적 Bankart 복원술시 봉합 나사못이 가장 이상적인 봉합기구로 알려져 있으며 여러 병리 상태를 고려하여 관절경적 복원술을 시행한 결과 여러 학자들이 과거에 비해 좋은 결과를 보고하고 있다(Table 2). 따라서 술기상으로 보다 숙련된 술식을 통해 재발율을 낮출 수 있으며 보다 좋은 결과를 얻기 위하여 수술 후 적극적인 재활 프로그램이 요할 것으로 생각된다.

  • PDF

Arthroscopic Repair of Type V SLAP lesion with Bio-knotless Anchor (제 5형 SLAP 병변에 대하여 Bio-knotless 봉합 나사못을 이용한 관절경적 봉합 수술의 임상적 결과)

  • Yum, Jae-Kwang;Lee, Sang-Lim;Ra, Ho-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.32-38
    • /
    • 2007
  • Purpose: This study reports the clinical results of the arthroscopic repair of type V SLAP lesion with bio-knotless anchor. Materials and Methods: 10 cases of 10 patients (10 male) were included in this study. The average age was 32.7 years old and the period from the first injury to operation was average 47.2 months. Preoperative Rowe score was average 37.5. Arthroscopic SLAP repair with 1 or 2 bio-knotless anchors were performed and arthroscopic Bankart repair with bio-knotless anchors were performed in all cases; 3 anchors were used in 7 cases and 2 anchors in 3 cases. The average follow up period was 15.7 months. Results: The Rowe score improved to 93 at last follow up period and 8 cases had full range of motion of the shoulder. 2 case had mild limited range of motion of the shoulder (one case; 170 degrees in flexion, 60 degrees in external rotation and T12 level in internal rotation, the other case; 160 degrees in flexion, 45 degrees in external rotation and T12 level in internal rotation.) without any problem in normal activity. Conclusion: Arthroscopic repair with bio-knotless anchor in type V SLAP lesion is one of the good methods because of the good clinical results.

  • PDF

Arthroscopic Cannulated Screw Fixation of Avulsion Fracture of the Intercondylar Eminence of the Tibia in a Child -A Case Report- (소아에서 발생한 전방 십자인대 견열 골절에서 유관 나사못을 이용한 관절경적 정복술 -증례보고-)

  • Moon, Kyu Pill;Kim, Kyung Taek;Kang, Min Soo;Park, Won Ro
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Avulsion fractures of the intercondylar eminence of the tibia are uncommon. This kind of fracture is most commonly found in adolescents, with an increasing incidence for those involved in competitive athletics. Recently, an arthroscopic procedure is preferred to reduce the operation-related morbidity. Screws, K-wires, Suture anchor have been described as fixation devices. Cannulated screw fixation is a simple method, but this instrument has the risk of causing damage to the growth plate. The authors report good results using cannulated screw in arthroscopic treatment for pediatric anterior cruciate ligament avulsion fracture.

  • PDF