• Title/Summary/Keyword: 봉합법

Search Result 122, Processing Time 0.021 seconds

Arthroscopic Rotator Cuff Repair: Single Row Technique (관절경적 회전근 개 봉합술: 일열 봉합 수기)

  • Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.155-159
    • /
    • 2007
  • Arthroscopic single-row rotator cuff repair is a well established surgical technique for the treatment of rotator cuff tears. However, the problem of postoperative retear remains a concern. Various avenues are being explored to address this problem. Some studies have suggested that restoring the anatomical footprint may improve the healing and initial strength of the repaired rotator cuff tendon. The double-row technique was introduced as a method of reconstructing the anatomical footprint. According to biomechanical studies on cadavers, this technique improved mechanical strength and reduced gap formation. However, the biological properties of reattached tendon such as tension, and vascularity have not been proved yet. Furthermore, the apparent mechanical superiority of the double-row over the single-row construction has not resulted in better functional outcomes. Therefore, the less complicated and less costly single-row technique is still the recommended treatment for rotator cuff repairs.

New V-shaped Technique in SLAP Repair (Comparison of Cinical Results Between New V-shaped Repair and Conventional Rapair Technique in Arthroscopic Type II SLAP Surgery) (SLAP 병변 수술에 사용 가능한 새로운 V자 봉합 (Type II SLAP 병변의 관절경적 수술에 있어 새로운 V자 형태의 봉합술기와 기존의 방법과의 임상결과 비교))

  • Hyun, Yoon-Suk;Shin, Sung-Il;Kang, Jung-Woo;Ahn, Joo-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Purpose: The purpose of this study was to compare clinical outcomes between the new V-shaped repair method and conventional methods for the arthroscopic repair of Type II SLAP lesions. Materials and Methods: Our study population consisted of 23 people treated with the new V-shaped repair method or conventional methods in the arthroscopic repair of Type II SLAP lesions at our institution between May 2006 and October 2008. Eleven shoulders were treated using the new V-shaped repair method. Twelve shoulders were treated using conventional methods. The average follow up period was 15 months. For evaluation of clinical results, we used UCLA and VAS pain scores. Results: Comparing change scores (preoperative vs. postoperative states) there were no significant differences in UCLA score or VAS score between the two groups. Conclusion: The new V-shaped repair technique elicits similar clinical results with conventional arthroscopic repair techniques and thus can be considered a useful alternative when using an absorbable suture that is anchor linked with only one suture.

Is the UU Stitch Really Alternative to Modified MA (Mason-Allen) Stitch for Rotator Cuff Repair? - Biomechanical Comparative Study of UU to Modified MA Stitch - (회전근 개 파열의 봉합에서 UU 봉합법은 변형된 MA(Mason-Allen) 봉합법을 대치할 수 있는가? - UU 봉합법과 변형된 MA 봉합법의 생역학적 비교-)

  • Friedman, Darren J;Ko, Sang-Hun;Park, Ki-Bong;Jun, Hyung-Min;Kim, Tae-Won;Lim, Hyun-Woo;Yum, Young-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • Purpose: In arthroscopic rotator cuff repairs there are generally weak link in tendon suture interface, arthroscopic rotator cuff repairs can have higher retear rates than open repairs. The purpose of this study was to compare the strength of UU (Ulsan University) suture than open modified MA (Mason-Allen) suture when suture anchored into bone. Materials and Methods: The human supraspinatus tendons were harvested from the shoulder of the cadaver and split in 2 times, producing four tendons per one shoulder, for a total of 24 specimens. Two suture configurations (UU, MA) were randomized and checked on each set of tendons. Specimens were cyclically loaded under force control between 5 and 30 N at 0.25 Hz for fifty cycles. Each specimen was loaded to failure under displacement control at 1 mm/sec. Cyclic elongation, peak to peak displacement, stiffness, ultimate tensile load, mode of failure were checked. Results: No significant difference was found between two suture configuration with respect to peak to peak displacement, cyclic elongation, and stiffness. With regard to ultimate failure load, there were no significant difference statistically between the UU suture and modified MA suture (109.4 N, 110.6 N). The most common mode of failure between both sutures was suture pull-out through the tendon. Conclusion: The UU suture and modified MA suture produced similar biomechanical properties.

A Comparison of Three Suture Techniques on Adhesion in End-to-end Intestinal Anastomosis of Dogs (개에서 세가지 단단장문합 봉합법에 따른 유착비교)

  • Kim, Je-Sun;Jeong, Soon-Wuk;Kim, Joon-Young;Jeong, Man-Bok;Han, Hyun-Jung
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • In this study, we evaluated effects of three anastomotic techniques of small intestine on adhesions in the dog. Twenty six healthy mixed dogs were randomly assigned to three groups. Group I(n = 8) was sutured with a simple continuous suture, group II(n = 7) was sutured with a simple interrupted approximating suture and group III(n = 11) was sutured with a single layer continuous Connell suture. On completion of any intestinal anastomosis, a pedicle of greater omentum was wrapped around the suture line in all experimental dogs. One percent sodium carboxymeth-ylcellulose (5ml/kg) was administrated into the abdomen by feeding tube prior to closing the last part of peritoneum in all dogs. Postoperative adhesions were evaluated at 14th day after operation. The adhesions consisted primarily in two dogs in group I, three dogs in group II and group III. There were adhesions between intestinal serosal surfaces in eight dogs in all groups, but there were no intestinal serosa-visceral peritoneum adhesion and intestinal serosa-mesentery adhesion. Mean adhesion scores were less than score 2 in all groups. Between anastomotic site and omental graft, there were 13.13$\pm$4.97 mm (mean$\pm$S.D.) adhesion formation in group I and 17.29$\pm$4.68 mm in group II and 14.64$\pm$3.80mm in group III. A simple continuous suture resulted in the least adhesion formation and a simple interrupted approximating suture resulted in the greatest adhesion formation among the groups. However, there were no significant differences among three suture techniques in the severity of adhesions. Intestinal intussusception only encountered in one dog during the 14 days, the dog operated and survived. Daily monitoring of temperature, activity, appetite, defecation and micturition were done. All of those vital signs were within normal values and there were no obvious differences among the groups. In conclusion, even though there were no significant differences among three groups, a simple continous suture pattern is recommended to prevent adhesions when operating intestinal anastomosis in dogs.

Arthroscopic Repair of the Postero-medial or Postero-lateral Capsule Tear in the Knee Joint - Technical Note - (슬관절 후내측 혹은 후외측 관절막 파열의 관절경적 봉합술 - 수술 수기 -)

  • Ahn Jin-Hwan;Cho Yang-Bum;Lee Yong-Seuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.135-139
    • /
    • 2001
  • Purpose : Repair of the posterior capsule tear at the time of the operation for the chronic postero-lateral or postero-medial rotary instability has not been reported. We describe the arthroscopic repair of the posterior capsule tear using the posterior trans-septal portal. Method : After conducting basic arthroscopic examination of the knee, postero-medial and postero-lateral portals are secure to make the posterior trans-septal portal, through which the postero-medial and postero-lateral capsule tears are repaired using the suture hook under the arthroscopic guidance. Conclusion : When arthroscopic reconstruction of PCL insufficiency or postero-lateral rotaty instability that accompanies postero-medial or postero-lateral capsular tears. rising the posterior traits-septal portal could ensure better visualization of the capsule and a subsequent more accurate repair of the capsule. Since it significantly lessened instability, it could contribute to an achievement of successful clinical results.

  • PDF

Arthroscopic All Inside Repair of Lateral Meniscus Root Tear -Technical note- (외측 반월상 연골 경골 후방 부착부 파열의 관절경적 All-Inside 봉합술 - 수술술기 -)

  • Ahn, Jin-Hwan;Lee, Dong-Hoon;Chang, Moon-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2007
  • Purpose: The authors introduce a new technique of arthroscopic all inside repair using anterolateral and anteromedial portals for lateral meniscus root complete radial tear in patients who underwent concurrent anterior cruciate ligament (ACL) reconstruction. Operative technique: Arthroscope is placed through anteromedial portal and suture hook ($Linvatec^{TM}$, Largo, Florida, USA) is delivered through anterolateral portal. By rotating the suture hook, it penetrates posterior horn of the torn meniscus from femoral to tibial surface for vertical orientation. PDS No. 1 ($Ethicon^{TM}$, Somerville, NJ, USA) is delivered through the suture hook, and then it is withdrawn. Both end of PDS No. 1 are taken out through the anterolateral portal. MAXON 2-0 ($Syneture^{TM}$, Norwalk, Connecticut, USA) is used to penetrates remnant of tibial attachment of the torn meniscus from tibial to femoral surface in a same manner. MAXON 2-0 is changed for PDS No. 1 from tibial to femoral surface by shuttle relay technique. PDS No. 1 is tied using SMC (Samsung Medical Center) knot. Conclusion: All inside repair is a useful technique to achieve anatomical repair and to restore the hoop tension in lateral meniscus root complete radial tear.

  • PDF

Alternative Technique of Aortic Valve Replacement -Implantation of Mechanical Aortic Valve at a Supra-Annular Level- (기계판막을 판륜상연에 위치시킨 대동맥판 치환술)

  • 최종범;이삼윤
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.504-509
    • /
    • 1996
  • When a valve prosthesis is to be implanted in the aortic position, simple interrupted suture, figure-of- eight suture, or horizontal mattress suture technique is used as a suture method. However, the suture techniques may be unacceptable for aortic valve replacement in patients with friable annulus caused by some lesions, such as endocarditis and degenerative change. We used an alternative technique for the aortic vlave replacement in 4 patients with valve endocarditis, ) patients with degenerative valvular lesion, and 1 with rheumatic valvular disease. Mattress sutures through the annulus were placed with pledgets on the ventricular side of the annulus, whi h resulted in implantation of the prosthesis at a supra-annular level. Mechanical valves of 21 mm or larger were implanted in the supra-annular position in all patients and there was no impeded motion of leaflets during the follow-up period of mean 13.3 mouths. The transvalvular pressure gradient was less than 6 mm Hg in 3 patients and 20 to 40 mm Hg in 5 patients. The supra-annular implantation of mechanical aortic valve using a vertical mattress suture technique may be a useful alternative method of aortic valve replacement for the selected patients with friable or destroyed aortic annulus.

  • PDF

Modified Inside-Out Suture Technique for Meniscus Repair (변형된Inside-Out 술식을 이용한 반월상 연골 봉합술)

  • Ahn Jin-Hwan;Wang Joon-Ho;Yoo Jae-Chul;Kim Hyung-Gun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.118-123
    • /
    • 2002
  • Purpose: To report modified technique of inside-out suture in repair of tear of postero medial corner of medial meniscus. Operative technique: Arthroscope is placed through anterolateral portal. Suture hook is delivered through anteromedial portal. By rotating the suture hook, it penetrates the inner portion of the torn meniscus from femoral surface to tibial surface of the meniscus for vertically oriented suture. A PDS suture is delivered through the lumen of suture hook, and the suture hook is withdrawn. The both ends of the suture are retrieved through anteromedial portal by a retriever, either grasper or crochet hook.A Zone-specific cannula is positioned below the inferior surface of the meniscus through anterolateral portal. The Looped Needle designed by the authors is delivered through the lumen of the Zone-specific cannula. The suture end of the tibial surface is placed in the loop of the Looped Needle and pulled out to the surface of posteromedial joint line. The suture end of the femoral surface is pulled out in same manner. A transverse skin incision of 1cm size is made adjacent to pulled out suture and the suture is tied. Discussion: Even though modified inside-out suture technique requires longer operation time than conventional inside-out technique, it provides vertically oriented suture and good tissue coaptation. The authors recommend this modified inside-out suture technique to be good alternative in repairing tear of the posteromedial corner of medial meniscus.

  • PDF

Arthroscopic UU-Tension Band Suture for Rotator Cuff Tear above 4 cm - Comparative Study with Simple Suture - (큰 크기의 회전근 개 파열에서 UU-Tension Band Suture를 이용한 관절경 감시하의 봉합술 - 단순 봉합술과의 비교 -)

  • Ko, Sang-Hun;Lee, Chae-Chil;Shin, Seung-Myeong;Kim, Sang Woo;Cho, Bum-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.99-108
    • /
    • 2012
  • Purpose: To evaluate the clinical results of arthroscopic repair with UU-Tension Band suture for full thickness rotator cuff tear above 4 cm sized. Materials and Methods: From January 2006 to October 2011, in 71 full thickness tears above 4 cm sized which is possible to arthroscopic repair to medial margin of greater tuberosity. The group I is 71 patients which is arthroscopic repair with UU-Tension Band suture, and the group II is 20 cases which is arthroscopic repair with simple suture. Both groups were compared with a VAS score for pain, Activity of Daily Living, UCLA score, KSS score in pre operation, 7 months, 1 year and last follow-up. Statistical analysis was performed by student t test and paired t est. Mean age was 63.2 (52~80) year old, mean follow-up was 38.4 (13~62) months. Results: The VAS scores for pain decreased from 8.1 at preoperative period to 1.6 at postoperative last follow-up period in group I (p<0.05), the score decreased from 7.6 at preoperative period to 1.8 postoperative last follow-up period in group II (p<0.05). The significant difference was not noted between two groups (p<0.05). Mean ADL scores increased from 12.5 at preoperative period to 29.0 post operative last follow-up period in group I (p<0.05), the score increased from 11.3 in pre op to 27.5 post-operative last follow-up in group II (p<0.05). The significant difference was not noted between two groups (p<0.05). The UCLA score increased from 12.9 at preoperative period to 28.7 postoperative last follow-up period in group I (p<0.05), the score increased from 13.8 at preoperative period to 30.1 postoperative last follow-up period in group II (p<0.05). The significant difference was not noted between two groups (p<0.05). In comparing of retear which was checked by MRI and ultrasound evaluated at postoperative period 7 months (mean: 27.5 weeks), the retears were 28% in the group I, and 11 shoulders out of 20 shoulders in the group II. The significant differences were noted between two groups (p<0.05). Conclusion: Arthroscopic repair with UU-Tension Band suture and simple suture for full thickness rotator cuff tear above 4 cm sized were not different clinical result between both groups. However, the significant differences were noted in point of failure rate between both groups.