• Title/Summary/Keyword: 복합재 디스크

Search Result 21, Processing Time 0.032 seconds

Performance Evaluation of Multi-Friction Dampers for Seismic Retrofitting of Structures (구조물 내진보강을 위한 다중 마찰댐퍼의 성능 평가)

  • Kim, Sung-Bae;Kwon, Hyung-O;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.54-63
    • /
    • 2022
  • This paper is a study on the friction damper, which is one of the seismic reinforcement devices for structures. This study developed a damper by replacing the internal friction material with ultra high molecular weight polyethylene (UHMWPE), a type of composite material. In addition, this study applied a multi-friction method in which the internal structure where frictional force is generated is laminated in several layers. To verify the performance of the developed multi-friction damper, this study performed a characteristic analysis test for the basic physical properties, wear characteristics, and disc springs of the material. As a result of the wear test, the mass reduction rate of UHMWPE was 0.003%, which showed the best performance among the friction materials based on composite materials. Regarding the disc spring, this study secured the design basic data from the finite element analysis and experimental test results. Moreover, to confirm the quality stability of the developed multi-friction damper, this study performed an seismic load test on the damping device and the friction force change according to the torque value. The quality performance test result showed a linear frictional force change according to the torque value adjustment. As a result of the seismic load test, the allowable error of the friction damper was less than 15%, which is the standard required by the design standards, so it satisfies the requirements for seismic reinforcement devices.

THE EFFECT OF LIGHT CURING METHODS AND RESIN ADHESIVES ON THE MICROLEAKAGE OF RESTORATIONS IN PRIMARY TEETH (광중합 방법 및 레진 접착제의 종류에 따른 유치 수복물의 미세누출)

  • Jeong, Young-Nam;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.592-599
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the effects of several light curing methods and several adhesives on the microleakage of composite resin restorations in primary teeth. Materials and methods : In 150 extracted human primary anterior teeth, O-shaped cavities were prepared in the labial surface ; the cavity diameter and depth were 1.6mm. The cavities were filled with light-activated composite resin, Compoglass. Four kinds of adhesives were used. Each filling materials were polymerized with three light cure methods. The restorations were polished using Sof-Lex discs(3M Co., USA). The samples were thermocycled 1,000 times between $5^{\circ}C$ and $55^{\circ}C$ with a 1-minute dwell time. Then, they were immersed in a 2% methylene blue solution(pH 7) for 12hours. Subsequently they were sectioned labio-lingually through the center of the restoration with a diamond saw at low speed with a water coolant, and evaluated by stereomicroscopy. Microleakage analyses were done, using scores from 0 to 4. Results : Results showed the least microleakage in Compoglass group(P<0.05). There were less microleakage in SBMP group among the adhesive groups, but no significant difference was observed(P>0.05). And there were no significant differences among the groups depending on curing methods(P>0.05).

  • PDF

AN EVALUATION OF WEAR CHARACTERISTICS OF LIGHT-CURED RESTORATIVE COMPOSITES ON ENAMEL SURFACE (광중합형 복합레진과 법랑질간의 마모특성 평가)

  • Baik, Byeong-Ju;Lee, Seung-Young;Lee, Doo-Cheol;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.261-270
    • /
    • 2001
  • This study was performed to evaluate wear characteristics of light-cured composites when opposed by human enamel. Seven light-cured restorative composites were selected and enamel cusps sectioned from premolars. All samples were stored in distilled water at $37^{\circ}C$ for 10 days. 68.6 N of weight was loaded during the test. The measurements of vertical loss of enamel cusps, weight loss and volume loss of composites, and SEM observations of the polished and abraded surfaces were made after 30,000 cycles. The results obtained were summarized as follows; 1. The highest hardness value of 70.4 was observed in the Spectrum group and the lowest value of 19.8 was observed in the Heliomolar group. Results of Tukey test showed that an overall significant difference was indicated except the Spectrum, Z100 and Clearfil AP-X groups(p<0.05). 2. Enamel showed the good abrasion resistance against the Heliomolar group of microfilled composite and the Palpique Toughwell group containing the submicron hybrid type spherical fillers. 3. The abrasive wear resistance of hybrid composites was improved with the decrease of mean particle size and hybrid of submicron particle fillers. 4. SEM observation of worn surfaces revealed the protrusion, attrition and missing of fillers, cracks developing and delamination in the matrix.

  • PDF

Development and Evaluation for the Insulated Coupling Test Machine of a Large Wind Turbine (대형 풍력터빈 절연커플링 시험장치 개발 및 평가)

  • Ju, Sung Ha;Kim, Dong Hyun;Oh, Min Woo;Kim, Su Hyun;Kang, Jong Hun;Bae, Jun Wu;Lee, Hyoung Woo;Kim, Kyung He
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.543-556
    • /
    • 2016
  • In this work, an insulated coupling test machine for a 5-MW-class wind turbine was designed and developed, along with the public performance testing of a 3-MW-class wind turbine. The results of the device design, development requirements, functional considerations, structural vibration analysis, and the evaluation of the insulated coupling test machine are presented in this study. For the coupling models, thick fiberglass composite pipe insulation, fabricated by filament winding, was considered. Results of three-dimensional finite element analysis conducted using both solid element and shell element modeling were analyzed and compared, considering the effect of thickness. In addition, results from the nonlinear finite element analysis of multiple leaf springs of the laminated disk pack structure were verified and compared with experimental data.

Effect of glycerin on the surface hardness of composites after curing (글리세린이 복합레진의 중합 후 표면경도에 미치는 영향)

  • Park, Hyun-Hee;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.483-489
    • /
    • 2011
  • Objectives: The purpose of this study was to examine the effect of glycerin topical application on the surface hardness of composite after curing. Materials and Methods: A composite (Z-250, 3M ESPE) was packed into a disc-shaped brass mold and light cured according to one of the following protocols. Group 1 (control) was exposed to air and light cured for 40 sec, group 2 was covered with a Mylar strip and light cured for 40 sec, group 3 was surface coated with glycerin and light cured for 40 sec, and group 4 was exposed to air and light cured for 20 sec and then surface coated with glycerin and cured for additional 20 sec. Twenty specimens were prepared for each group. The surface hardnesses of specimens were measured with or without polishing. Five days later, the surface hardness of each specimen was measured again. Data were analyzed by three-way ANOVA and Tukey's post hoc tests. Results: The surface hardnesses of the unpolished specimens immediately after curing decreased in the following order: group 2 > 3 > 4 > 1. For the polished specimens, there was no significant difference among the groups. Within the same group, the hardness measured after five days was increased compared to that immediately after curing, and the polished specimens showed greater hardness than did the unpolished specimens. Conclusions: The most effective way to increase the surface hardness of composite is polishing after curing. The uses of a Mylar strip or glycerin topical application before curing is recommended.

Numerical Study on the Flow Characteristics according to the Ventilation Holes Shape of the Carbon Composite Brake Disk (탄소복합재 브레이크 디스크의 통풍구 형상에 따른 유동특성에 관한 해석적 연구)

  • Ko, Dongguk;Yoon, Suckju
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • In this study, the flow characteristics at the ventilation holes was analyzed by using numerical method when carbon composite brake disk was rotated at a constant speed. In order to ensure the validity of the analysis results, grid dependency test was performed by considering the accuracy and appropriateness, and 4mm mesh size was selected for decrease of the maximum error rate 63.6%. As a result, the outside air flows in the clearance between the disk and shaft in case of B model. whereas, the outside air flows in the clearance or the outlet of the ventilation holes in case of A and C models. And also average static pressure at the outlet was changed depending on shape of the ventilation holes and rotational speed of the disk in case of A and C models. Besides, in the B model, intake air according to the clearance goes with side surface of ventilation hole, and so increased by mean velocity of 4.64m/s and mean pressure of 0.58pa in the ventilation hole outlet, in case of disk rotational speed of 146.21rad/s.

Antimicrobial Synergistic Effects of Gallnut Extract and Natural Product Mixture against Human Skin Pathogens (피부 병원성균에 대한 오배자 천연 복합물의 시너지 항균 효과)

  • Kim, Ju Hee;Choi, Yun Sun;Kim, Wang Bae;Park, Jin Oh;Im, Dong Joong
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.2
    • /
    • pp.155-161
    • /
    • 2021
  • This study was attempted to investigate natural materials with antimicrobial activity and to apply as natural preservatives in cosmetics. The disc diffusion method was used to search for nine species of natural antibacterial material for three species of skin pathogenic bacteria (Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa) and Candida albicans. As a result of measuring the size of inhibition zone, Rhus Semialata gall (Gallnut) extract, Oak vinegar, and ε-polylysine were showed strongest antibacterial activities (> 10 mm). The Minimum Bactericidal Concentration (MBC) of gallnut and oak vinegar ranged from 10 to 20 mg/mL and from 20 to 40 mg/mL against five human skin pathogens. The MBC of ε-polylysine ranged from 0.5 to 2 mg/mL in fungus. The synergic effect of gallnut extract/oak vinegar mixture and gallnut extract/ε-polylysine mixture were evaluated by checkerboard test. Compared to when used alone, the MBC of gallnut extract/oak vinegar mixture were at 4 times lower concentration against E. coli, C. albicans, and A. brasiliensis. Also Furthermore, the MBC of gallnut extract/ε-polylysine mixture were at 4 times lower concentration against C. albicans and A. brasiliensis. It was confirmed that the combination of gallnut extract with oak vinegar or ε-polylysine resulted in synergistic antibacterial effect against three human skin pathogens. Thus, it is expected that gallnut extract and natural product mixture can not only demonstrate antibacterial synergies, but also be applied in cosmetics as a natural preservative system with a wide antibacterial spectrum.

The Hybrid Fault Tolerant Technique for Embedded System (임베디드 시스템을 위한 복합 결함 허용 기법)

  • Kook, Joong-Jin;Hong, Ji-Man
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06b
    • /
    • pp.273-278
    • /
    • 2007
  • 검사점 및 복구 도구(Checkpointing & Recovery Facility)를 이용하여 임베디드 시스템에서 결함 허용(Fault Tolerance) 기법을 적용할 경우 쓰기 작업의 오버헤드로 인해 실용성이 크게 떨어지게 된다. 실시간 운영체제와 함께 어떠한 한계 상황에서 결함 허용 및 복구 도구가 오히려 시스템의 성능을 저하시키는 요인으로 작용하게 되면 이는 결국 쓸모없는 도구가 되어 사용되지 않을 것이다. 따라서 프로세스의 복구를 위해 저장하는 프로세스 이미지의 기록에 소요되는 시간을 크게 낮추어야만 비로소 검사점 도구가 그 진가를 발휘하게 될 수 있다. 본 논문에서는 NVSRAM(Non Volatile SRAM)을 검사점 및 복구 도구의 저장 장치로 활용함으로써 기존의 검사점 도구에서 성능을 저하시키는 주원인이었던 검사점 기록의 오버헤드를 개선하기 위한 연구를 수행하였다. 검사점 기록 시간을 줄이기 위한 방법으로 주 메모리에 저장된 프로세스의 복구와 관련된 데이터를 SRAM 특성을 갖는 비휘발성 저장 장치인 NVSRAM에 저장하여 디스크 접근에 소요되는 시간을 최소화시킴으로써 임베디드 시스템에서 실용적으로 사용 가능한 검사점 도구를 구현하였고, 이러한 연구의 결과를 검증하기 위해 기존 시스템에서 저장 장치로 사용되던 플래시 메모리, 주 메모리, 원격 메모리를 사용하는 경우의 성능과 NVSRAM을 활용할 때의 성능을 비교해 보았다. 본 연구에서 제안하는 결함 허용 도구는 실제 시스템에 적용하여 효과적인 성능을 발휘할 수 있을 것이며, 차세대 메모리를 이용한 결함 허용 도구의 연구에 기여를 할 수 있을 것으로 기대된다.ate첨가배지(添加培地)에서 가장 저조(低調)하였다. vitamin중(中)에서는 niacin과 thiamine첨가배지(添加培地)에서 근소(僅少)한 증가(增加)를 나타내었다.소시켜 항이뇨 및 Na 배설 감소를 초래하는 작용과, 둘째는 신경 경로를 통하지 않고, 아마도 humoral factor를 통하여 신세뇨관에서 Na 재흡수를 억제하는 작용이 복합적으로 나타내는 것을 알 수 있었다.으로 초래되는 복합적인 기전으로 추정되었다., 소형과와 기형과는 S-3에서 많이 나왔다. 이상 연구결과에서 입도분포가 1.2-5mm인 것이 바람직한 것으로 나타났다.omopolysaccharides로 확인되었다. EPS 생성량이 가장 좋은 Leu. kimchii GJ2의 평균 분자량은 360,606 Da이었으며, 나머지 두 균주에 대해서는 생성 EPS 형태와 점도의 차이로 미루어 보아 생성 EPS의 분자구조와 분자량이 서로 다른 것으로 판단하였다.TEX>개로 통계학적으로 유의한 차이가 없었다. Heat shock protein-70 (HSP70)과 neuronal nitric oxide synthase (nNOS)에 대한 면역조직화학검사에서 실험군 Cs2군의 신경세포가 대조군 12군에 비해 HSP70과 nNOS의 과발현을 보였으며, 이는 통계학적으로 유의한 차이를 보였다(p<0.05). nNOS와 HSP70의 발현은 강한 연관성을 보였고(상관계수 0.91, p=0.000), nNOS를 발현하는 세포가 동시에 HSP70도 발현함을 확인할 수 있었다. 결론: 우리는 cyclosporin A가 토끼의 25분간의 척수허혈에 대해 척수보호 효과가 있었으며 이는 HSP70의

  • PDF

COMPARATIVE STUDY ON FLUORIDE RELEASE AND RE-UPTAKE CAPACITY OF SEVERAL FLUORIDE-RELEASING RESTORATIVE MATERIALS (수종의 수복재의 불소 적용법에 따른 불소 유리에 관한 비교 연구)

  • Lee, Yeon-Ho;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.25-34
    • /
    • 2006
  • Fluoride released from dental restorative materials effectively declines the incidence and activity of dental caries and inhibits tooth demineralization. This study investigated the fluoride release and uptake characteristics of one composite resin $(Z-250^{TM})$ three glass ionomer-based restorative material ($Dyract^{(R)}$ AP, Fuji II $LC^{(R)}$, Fuji IX GP $Fast^{(R)}$) Forty discs(6mm diameter and 1mm height) were prepared for each material. Each disc was immersed in 5ml of distilled water within polyethylene vial and stored at $37^{\circ}C$. The distilled water was changed every 24 hours and the release of fluoride was measured for 31 days. At the end of this period, each specimen was subjected to one of four treatments : (A) no fluoride treatment (control), (B) application of a fluoride dentifrice (500ppm) for three minutes three times; (C) application of the 1.23% acidulated phosphate fluoride(APF) foam for one minute once, (D) the same regimen as (B), plus application of the APF foam for one minute once. Then, all samples were reassessed for an additional 7 days. For all samples, the greatest fluoride release was observed after the first day of the study but diminished with time. On the 7th day of the study, fluoride release level was stabilized. Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$ released higher amount of fluoride than other materials ; however, no statistically significant difference was found from Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$. The amount of fluoride of $Dyract^{(R)}$ AP, Fuji II $LC^{(R)}$ and Fuji IX GP $Fast^{(R)}$ was increased after fluoride treatment, and diminished with time.

  • PDF

COMPARATIVE STUDY ON REMINERALIZING EFFECT OF COMPOMERS (컴포머의 재석회화 효과에 관한 비교 연구)

  • Chung, Hoi-Min;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.498-508
    • /
    • 2002
  • The purpose of this study was to compare the amount of fluoride release and remineralizing effect of compomer with those of glass ionomer cement and composite resin. Composite resin($Z-100^{(R)}$) was used for negative control group(Group I), glass ionomer(Fuji II $LC^{(R)}$) for positive control group(Group IV), compomer(Dyract $AP^{(R)}$ and $F-2000^{(R)}$) for experimental group(Group II and Group III). The results obtained can be summarized as follows : 1. Glass ionomer showed the higher amount of fluoride release than compomer groups. Composite resin showed no fluoride release during test period. 2. Significant evidence of remineralization could be noticed in samples of all groups. The highest degree of remineralization was observed in glass ionomer group followed by compomer group. The least evidence of remineralization was observed in composite resin group. 3. Microhardness values of carious site was lower than control site, but Microhardness values of caries site at form away from filling materials in group II, III, IV was significantly higher than the other area. Based on the above results, compomer could be considered as one of the very attractive restorative materials in the field of pediatric dentistry.

  • PDF