• Title/Summary/Keyword: 복소수 데이터

Search Result 51, Processing Time 0.031 seconds

Acceleration of FFT on a SIMD Processor (SIMD 구조를 갖는 프로세서에서 FFT 연산 가속화)

  • Lee, Juyeong;Hong, Yong-Guen;Lee, Hyunseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.97-105
    • /
    • 2015
  • This paper discusses the implementation of Bruun's FFT on a SIMD processor. FFT is an algorithm used in digital signal processing area and its effective processing is important in the enhancement of signal processing performance. Bruun's FFT algorithm is one of fast Fourier transform algorithms based on recursive factorization. Compared to popular Cooley-Tukey algorithm, it is advantageous in computations because most of its operations are based on real number multiplications instead of complex ones. However it shows more complicated data alignment patterns and requires a larger memory for storing coefficient data in its implementation on a SIMD processor. According to our experiment result, in the processing of the FFT with 1024 complex input data on a SIMD processor, The Bruun's algorithm shows approximately 1.2 times higher throughput but uses approximately 4 times more memory (20 Kbyte) than the Cooley-Tukey algorithm. Therefore, in the case with loose constraints on silicon area, the Bruun's algorithm is proper for the processing of FFT on a SIMD processor.

CNN based Complex Spectrogram Enhancement in Multi-Rotor UAV Environments (멀티로터 UAV 환경에서의 CNN 기반 복소 스펙트로그램 향상 기법)

  • Kim, Young-Jin;Kim, Eun-Gyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.4
    • /
    • pp.459-466
    • /
    • 2020
  • The sound collected through the multi-rotor unmanned aerial vehicle (UAV) includes the ego noise generated by the motor or propeller, or the wind noise generated during the flight, and thus the quality is greatly impaired. In a multi-rotor UAV environment, both the magnitude and phase of the target sound are greatly corrupted, so it is necessary to enhance the sound in consideration of both the magnitude and phase. However, it is difficult to improve the phase because it does not show the structural characteristics. in this study, we propose a CNN-based complex spectrogram enhancement method that removes noise based on complex spectrogram that can represent both magnitude and phase. Experimental results reveal that the proposed method improves enhancement performance by considering both the magnitude and phase of the complex spectrogram.

Hybrid Photoelastic Stress Analysis Around a Central Crack Tip in a Tensile Loaded Plate Using Isochromatic Data (등색프린지 데이터를 이용한 인장하중 판재 중앙 균열선단 주위의 하이브리드 광탄성 응력장 해석)

  • Baek, Tae-Hyun;Chen, Lei
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.12
    • /
    • pp.1200-1207
    • /
    • 2007
  • An experimental test is presented for photoelastic stress analysis around a crack tip in tensile loaded plate. The hybrid method coupling photoelastsic fringe inputs calculated by finite element method and complex variable formulations involving conformal mappings and analytical continuity is used to calculate full-field stress around the crack tip in uniaxially loaded, finite width tensile plate. In order to accurately compare calculated fringes with experimental ones, both actual and regenerated photoelastic fringe patterns are two times multiplied and sharpened by digital image processing. Regenerated fringes by hybrid method are quite comparable to actual fringes. The experimental results indicate that Mode I stress intensity factor analyzed by the hybrid method are accurate within three percent compared with ones obtained by empirical equation and finite element analysis.

Modeling and Simulation Study of Multipath Ghosts (다중 경로 고스트의 모델링 및 시뮬레이션 연구)

  • Kwon, Sung-Jae
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.5
    • /
    • pp.675-686
    • /
    • 2005
  • This paper proposes a new method of mathematically modeling and computer simulating television ghosts wherein television signals that have undergone multipath fading are generated without using approximations by considering the attenuation, time delay, phase, and timing jitter between consecutive frames. Conventional methods used polynomial interpolation or complex arithmetic to take into account the ghost phase, but our method uses only real arithmetic by employing the Hilbert transform and also reduces the computation time using the FFT (fast Fourier transform) algorithm. Furthermore, it is also possible to observe the transmit waveforms in both RF and IF ranges. Various ghost patterns generated in software provide for essential data required for the development of ghost canceling algorithms, and are deemed to be very useful in analyzing the constituent blocks of the transmitter and receiver chain in television broadcasting. The development of ghost cancelers needs to be preceded by the task of mathematically modeling ghosts and their extensive computer simulations.

  • PDF

Hybrid Stress Analysis around a Circular Hole in a Tensile Plate by Use of Phase Shifting Photoelasticity (광탄성 위상이동법에 의한 인장시편 원형 구멍주위 하이브리드 응력해석)

  • Baek, Tae-Hyun;Lee, Choon-Tae;Yang, Min-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • A hybrid experimental-numerical method is presented for determining the stresses around a circular hole in a finite-width, tensile loaded plate. Measured fringe orders along straight lines provided the input information on the external boundary of the hybrid element. In order to see the effects of varying stress field, different numbers of terms in a power-series representation of the complex type conformal mapping stress function were tested. For qualitative comparison, actual isochromatic fringes were compared with reconstructed theoretical fringes using stress-optic law. For quantitative comparison, relative errors and standard deviations with respective to relative errors were analyzed for all measured points by changing the number of terms of stress function. The hybrid results are highly comparable with those predicted by FEA. The results show that this approach is effective and promising because isochromatic data along the straight lines in photoelasticity can be conveniently measured by use of phase shifting photoelasticity.

Design and implementation of the synchronization circuit for OFDM system without synchronization preambles (동기 프리엠블이 없는 OFDM 시스템의 동기회로 설계 및 구현)

  • 남우춘;한영열
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.1045-1057
    • /
    • 1997
  • In this paper, we propose an algorithm of block synchronization that uses data withoug synchronization preambles. Block synchronization systems is implemented using the DSP chip employing the proposed algorithm. The data spread of the DFT blocks is proportional to the offset of DFT block and this information is used to achieve the block synchronization in the receiver. The initial bleock synchronization and the clock synchronization between transmitter and receiver are achieved using the early-late removal of the guard interval. The hardware implmentation is carried out using the DSP chip TM320C30 to verify the proposed block synchronization algorithm with the data rate 1200bps. The DSP chip calculates the spread of the 128 complex FFT in the receiver with the system clock 30MHz. It is believed that the proposed synchronization algorithm can be used in the design of OFDM block synchronization with the high processing DSP chip.

  • PDF

Speckle-Free Digital Hologram with Conversion to Off-Axis Horizontal-Parallax-Only Hologram (탈축 수평 시차 홀로그램 변환과 스펙클 잡음 없는 디지털 홀로그램)

  • Kim, You Seok;Kim, Taegeun
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.85-89
    • /
    • 2014
  • In this paper, we present a speckle-free digital hologram with conversion to an off-axis horizontal-parallax-only (HPO) hologram. First, we record the speckle-free hologram using optical scanning holography. Second, we digitally convert the full-parallax hologram to a horizontal-parallax-only hologram. Third, we convert the horizontal-parallax-only hologram to an off-axis hologram. Finally, we show that the off-axis HPO hologram can be numerically reconstructed in space.

Blood Vessel Strain Imaging Using Linear Array Transducer (선형 트랜스듀서를 이용한 혈관 변형률 영상법)

  • Ahn, Dong-Ki;Jeong, Mok-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.880-890
    • /
    • 2010
  • The intrasvascular ultrasound (IVUS) imaging technique is used to diagnose cerebrovascular diseases such as stroke. Recently, elasticity imaging methods have been investigated to diagnose blood clots attached to blood vessel intima. However, the IVUS imaging technique is an invasive method that requires a transducer to be inserted into blood vessel. In this paper, strain images are obtained of blood clots attached to blood vessel intima with data acquired from outside the blood vessel using a linear array transducer. In order to measure the displacement of blood vessel accurately, experimental data are acquired by steering ultrasound beams so that they can intersect the blood vessel wall at right angles. The acquired rf data are demodulated to the baseband. The resulting complex baseband signals are then processed by an autocorrelation algorithm to compute the blood vessel movement and thereby produce strain image. This proposed method is verified by experiments on a plastic blood vessel mimicking phantom. The efficacy of the proposed method was verified using a home-made blood vessel mimicking phantom. The blood vessel mimicking phantom was constructed by making a 6 mm diameter hollow cylinder inside it to simulate a blood vessel and adhering 2 mm thick soft plaque to the inner wall of the hollow cylinder. The RF data were acquired using a clinical ultrasound scanner (Accuvix XQ, Medison, Seoul. Korea) with a 7.5 MHz linear array transducer by steering ultrasound beams in steps of $1^{\circ}$ from $-40^{\circ}$ to $40^{\circ}$ for a total of 81 angles. Experimental results show that the plaque region near the blood vessel wall is softer than background tissue. Although the imaging region is restricted due to the limited range of angles for which scan lines are perpendicular to the wall, the feasibility of strain imaging is demonstrated.

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Optimum Rake Processing for Multipath Fading in Direct-Sequence Spread-Spectrum Communication Systems (주파수대역 직접확산 통신시스템에서 다중경로 페이딩 보상을 위한 최적 레이크 신호처리에 관한 연구)

  • 장원석;이재천
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10C
    • /
    • pp.995-1006
    • /
    • 2003
  • It is well know that in the wireless communication systems the transmitted signals can suffer from multipath fading due to the wave propagation characteristics and the obstacles over the paths, resulting in serious reduction in the power of the received signals. However, it is possible to take advantage of the inherent diversity imposed in the multipath reception if the underlying channel can be properly estimated. One of the diversity reception methods in this case is Rake processing. In this paper we study the Rake receivers for the direct-sequence spread-spectrum communication systems utilizing PN (pseudo noise) sequences to achieve spread spectrum. A conventional Rake receiver can use the finite-duration impulse (FIR) filter followed by the PN sequence demodulator, where the FIR filter coefficients are the reverse-ordered complex conjugate values of the fading channel impulse response estimates. Here, we propose a new Rake processing method by replacing the aforementioned PN code sequence with a new set of optimum demodulator coefficients. More specifically, the concept of the new optimum Rake processing is first introduced and then the optimum demodulator coefficients are theoretically derived. The performance obtained using the new optimum Rake processing is also calculated. The analytical results are verified by computer simulation. As a result, it is shown that the new optimum Rake processing method improves the MSE performance more than 10 dB over the conventional one using the fixed PN sequence demodulator. It is also shown that the new optimum Rake processing method improves the MSE performance about 10 dB over the Adaptive Correlator that performs the combining of the multipath components and PN demodulation concurrently. And finally, the MSE performance of the optimum Rake demodulator is very close to the MSE performance of OPSK demodulator under the AWGN channel.