• Title/Summary/Keyword: 복사온도계

Search Result 15, Processing Time 0.026 seconds

Size-of-source Effect and Self-radiation Effect of an Infrared Radiation Thermometer (적외선 복사온도계의 복사원 크기효과 및 자기복사효과)

  • Yoo, Yong-Shim;Kim, Bong-Hwak;Park, Chul-Woung;Park, Seung-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.133-138
    • /
    • 2010
  • All radiation thermometers have a size-of-source effect (SSE) and a self-radiation effect (SRE). The SSE,defined as dependence of the detector signal of a radiation thermometer on the diameter of a source, is critically dependent on the wavelength since diffraction is the main cause. In this paper, we have measured the SSE and the SRE of TRT2 (Transfer Radiation Thermometer 2, HEITRONICS) widely used as a transfer standard in low and middle temperature range. At $300^{\circ}C$, The radiation temperature difference between the 60 mm diameter blackbody and 10 mm diameter blackbody due to the SSE was estimated to be $3.5^{\circ}C$ in low temperature mode ($8-14\;{\mu}m$) and $0.5^{\circ}C$ in middle temperature mode ($3.9\;{\mu}m$). In addition, the measured radiation temperature difference of the blackbody due to the SRE was found to be 110 mK when the body temperature change of TRT2 was set at $2.6^{\circ}C$.

Establishment of Comparison Calibration Equipment for Infrared-radiation Thermometers Below ℃ (℃ 이하 적외선 복사온도계 비교 교정장치 구축)

  • Yoo, Yong Shim;Kim, Bong-Hak
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.2
    • /
    • pp.70-76
    • /
    • 2018
  • Comparison calibration equipment for infrared-radiation thermometers below $0^{\circ}C$ has been established, using a TRT2 (transfer radiation thermometer 2, HEITRONICS) as a transfer standard and an ME30 (Model: ME30, HEITRONICS) as a variabletemperature blackbody. The TRT2 was calibrated using three fixed points (Ice ($0.01^{\circ}C$), In ($156.5985^{\circ}C$), and Sn ($231.928^{\circ}C$)) and the Planckian Sakuma-Hattori equation, and including the interpolation and extrapolation errors at $-50^{\circ}C$ in the uncertainty. The pneumatic lid is installed upon opening of the ME30 and is opened for only 30 seconds for measuring the radiation temperature, which prevents formation of ice in the ME30 and also reduces the calibration time to half. The farther away from the $0{\sim}232^{\circ}C$ region, the larger the uncertainty of the comparison calibration equipment becomes. The expanded uncertainty of the comparison calibration equipment was estimated as 0.26 K at $-20^{\circ}C$.

Improvement of Spatial Radiance Uniformity of Small Integrating Spheres (소형 적분구의 공간 복사 휘도 균일도 향상 연구)

  • Yong Shim Yoo;Dong Joo Shin;Bong Hak Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.5
    • /
    • pp.202-209
    • /
    • 2023
  • A KRISS-type small integrating sphere with a high spatial radiance uniformity was made using pressed polytetrafluoroethylene (PTFE) and a reflective rod to calibrate the spectral radiance responsivity of absolute radiant thermometers. The spatial radiance uniformity of the KRISS-type small integrating sphere was ±0.009%, five times higher than the best value reported by foreign national metrology institutions thus far. In addition, we improved the spatial radiance uniformity of a commercial sintered PTFE integrating sphere by a factor of 10.

Development of a radiation thermometer for the adaptive steel plant (제철소 적응형 복사온도계 개발)

  • Park, Sang-Gug
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.173-178
    • /
    • 2002
  • In this research, we have worked about the radiation thermometer which can be applied to the hazard circumstance such as steel plant. In the results, we have developed radiation thermometer of a measuring range $500-1500^{\circ}C$, accuracy ${\pm}0.1%$, repeatability ${\pm}0.1%$, resolution $0.2^{\circ}C$. We performed extensive field test for 6 months at the hot strip mill in steel plant. Through the test, we have confirmed the reliability of the developed pyrometer.

  • PDF

Control if Chip From by Adjusting Feed-rate (이송량 조정에 의한 칩의 형태 제어)

  • 전재억;심재형;백인환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.993-997
    • /
    • 1997
  • The continuous chip depresses the accuracy of workpieces and promotes the wear of machine tools and hunts operators. So chip control os a major problem in turning process. In this paper, a method of chip identification is develope by pyrometer. The identifier is applied in real-time control of chip pattern with adjusting feedrate.

  • PDF

연소진단 용 광대역 코헤런트 반 스톡스 라만 분광기의 제작 및 정확도 분석.

  • Park, Cheol-Ung;Park, Seung-Nam;Han, Jae-Won;Park, Bu-Min;Sin, Hyeon-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.33-44
    • /
    • 1997
  • 연소상태의 온도를 이동하면서 측정할 수 있는 광대역 코헤런트 반스톡스 라만 분광기를 제작하였다. 분광기의 온도 측정 정확도를 향상시키기 위하여 무모드레이저를 제작하여 스톡스광으로 사용하였다. 이동형 CARS 분광기에 적합하도록 CARS신호 측정용 단색기를 제작하여 분광기 내부에 설치 하였다. CARS 분광기의 온도 측정의 정확도를 알아보려고 흑연관 전기로를 이용하여 표준 복사온도계와 CARS 분광기로 측정한 온도의 차이를 측정하였다. 장치의 온도 정확도는 1000 K - 2400 K 사이의 온도영역에서 2%이내 였다. 무모드 색소레이저의 출력 스펙트럼의 시간에 따른 안정도를 측정하여 온도측정에 미치는 오차를 조사한 결과 1500 K에서 5 시간 동안 1.5 %이내 였다. 평면 화염 버너에서 프로판공기 예혼합 화염의 온도 분포를 측정하여 이 장치의 응용 가능성을 확인하였다.

  • PDF

Identification of the Chip Form Using Neural Network (신경망을 이용한 칩 형태의 인식)

  • 심재형;권혁준;백인환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.106-112
    • /
    • 1998
  • A major problem in automation of turning operations is the difficulty in obtaining a sufficient and reliable chip control. The chip should be detected in order to provide a optimum chip control for unmanned turning operation. Using the difference of energy radiated from the chip, chip Patterns are estimated using pyrometer. From the initial output from the pyrometer, chips are identified according to the backpropagation algorithm developed in the research. The learning system developed in this work can be applied in real-time control of turning process with minor modification in drive system.

  • PDF

Radiant Energy Filtering to Enhance High Temperature Measurement by a Thermography System (고온 계측 열화상 시스템 구현을 위한 복사에너지 필터링 연구)

  • Yoon, Seok Tae;Cho, Yong Jin;Jung, Ho Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.466-473
    • /
    • 2016
  • In a shipbuilding process, thermal damage to the ship structure at the rear end results from an excessive heat input and conduction during welding process. To prevent such damage, appropriate control of the heat input, based on welding temperature measurement, is required. For temperature measurement, contact and non-contact methods are available; the thermography system is a popular non-contact temperature measurement. When the intensity of radiation from a high-temperature object is excessive, however, detecting the sensors of ordinary thermography systems leads to an inability in measuring the temperature due to saturation. Hence, this study suggests use of a neutral density filter that prevents an excessive amount of radiation from being accumulated in a thermography system, and thus makes it possible to quantitatively measure an object's temperature as high as $3000^{\circ}C$.