• Title/Summary/Keyword: 복부판

Search Result 99, Processing Time 0.03 seconds

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior- (절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰-)

  • Hwang, Yoon Koog;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.363-375
    • /
    • 1997
  • This study encompasses the performance of static and fatigue test for the 8 large scale test specimens to clarify the fatigue behavior of coped stringer and the effect of the repair and strengthening on the damaged stringer of the floor system in steel railway bridges. For the purpose of the research, the actual stress wave for the existing bridge was measured, the basic stress range frequency histogram was made and the equivalent stress range was calculated. Using the result from the equivalent stress range made by adjusting the stress range, the static and fatigue test was carried out by identifying the previous rehabilitation and after. As the result of the static tests, it was revealed that the level of local stress under the S1 specimen test of the real equivalent stress range was similar to tensile strength of the test material, and it was consistent with the requirement of the initiation condition of the fatigue crack. Through the various rehabilitation methods to the damaged specimens, the effects of the repair and reinforcement were analyzed. According to the results of the repair of effect, bolting the high tension bolt over the stop hole was confirmed to be more adequate method than drilling only stop hole to delay the fatigue crack growth. Futhermore, in case of the stringer subjected by bending moment, the reinforcement over the upper flange side was determined to be a useful strengthening method, and the reinforcement to the web of the stringer was not appropriate to accomodate as a adequate strengthening method. Also it was confirmed that the category of the fatigue design for the coped stringer met with the category E specified on the fatigue design criteria of the Highway Standard Specification in Korea.

  • PDF

Calculation of Crack Width of the Top Flange of PSC Box Girder Bridge Considering Restraint Drying Shrinkage (구속 건조수축을 고려한 PSC BOX 거더교 상부플랜지 균열폭 산정)

  • Young-Ho Ku;Sang-Mook Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.30-37
    • /
    • 2023
  • The PSCB girder bridge is a closed cross-section in which the top and bottom flanges and the web are integrated, and the structural characteristics are generally different from the bridges in which the girder and the floor plate are separated, so a maintenance plan that reflects the characteristics of the PSCB girder bridge is required. As a result of analyzing damage types by collecting detailed safety diagnosis reports of highway PSCB girder bridges, most of the deterioration and damage occurring during use is concentrated on the top flange. In particular, cracks in the bridge direction on the underside of the top flange occurred in about 70 % of the PSCB girder bridges to be analyzed, and these cracks were judged to be caused by indirect loads such as heat of hydration and drying shrinkage rather than structural cracks caused by external loads. In order to improve durability and reduce maintenance costs of PSCB girder bridges in use, it is necessary to control restraint drying shrinkage cracks from the design stage. Therefore, in this paper, the cracks caused by drying shrinkage under restraint, which is the main cause of cracks under the flanges of the top part of the PSCB girder bridge, were directly calculated using the Gilbert Model, and the influencing factors such as the amount of reinforcing bars, diameter and spacing of reinforcing bars were analyzed. As a result of the analysis, it was found that the crack width caused by restraint drying shrinkage exceeded the allowable crack width of 0.2 mm for reinforcing bars with a reinforcing bar ratio of 0.01 or less based on the H16 reinforcing bar and a reinforcing bar with a diameter greater than H19 based on the reinforcing bar ratio of 0.01. Finally, based on the results of the crack width review, a method for controlling the crack width of the top flange of the PSCB girder bridge was proposed.

Multicenter clinical study of childhood periodic syndromes that are common precursors to migraine using new criteria of the International Classification of Headache Disorders (ICHD-II) (편두통의 전 단계인 소아기주기성증후군의 다기관 임상 연구: 국제두통질환분류 제2판 제1차 수정판 적용)

  • Park, Jae Yong;Nam, Sang-Ook;Eun, So-Hee;You, Su Jeong;Kang, Hoon-Chul;Eun, Baik-Lin;Chung, Hee Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.5
    • /
    • pp.557-566
    • /
    • 2009
  • Purpose : To evaluate the clinical features and characteristics of childhood periodic syndromes (CPS) in Korea using the new criteria of the International Classification of Headache Disorders (ICHD)-II. Methods : The study was conducted at pediatric neurology clinics of five urban tertiary-care medical centers in Korea from January 2006 to December 2007. Patients (44 consecutive children and adolescents) were divided into three groups (cyclic vomiting syndrome [CVS], abdominal migraine [AM], and benign paroxysmal vertigo of childhood [BPVC]) by recurrent paroxysmal episodes of vomiting, abdominal pain, dizziness, and/or vertigo using the ICHD-II criteria and their characteristics were compared. Results : Totally, 16 boys (36.4%) and 28 girls (63.6%) were examined (aged 4-18 yr), with 20 CVS (45.5%), 8 AM (18.2%), and 16 BPVC (36.4%) patients. The mean age at symptom onset was $6.3{\pm}3.6$ yr, $8.5{\pm}2.7$ yr, and $8.5{\pm}2.9$ yr in the CVS, AM, and BPVC groups, respectively, showing that symptoms appeared earliest in the CVS group. The mean age at diagnosis was $8.0{\pm}3.4$ yr, $10.5{\pm}2.6$ yr, and $10.1{\pm}3.2$ yr the CVS, AM, and BPVC groups, respectively. Of the 44 patients, 17 (38.6%) had a history of recurrent headaches and 11 (25.0%) showed typical symptoms of migraine headache, with 5 CVS (25.0%), 2 AM (25.0%), and 4 BPVC (25.0%) patients. Family history of migraine was found in 9 patients (20.4%): 4 in the CVS group (20.0%), 2 in the AM group (25.0%), and 3 in the BPVC group (18.8%). Conclusion : The significant time lag between the age at symptom onset and final diagnosis possibly indicates poor knowledge of CPS among pediatric practitioners, especially in Korea. A high index of suspicion may be the first step toward caring for these patients. Furthermore, a population-based longitudinal study is necessary to determine the incidence and natural course of these syndromes.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

A Clinical Manifestation of Meckel's Diverticulum (Meckel 게실의 임상양상)

  • Lee, Jin Beom;Lee, Yong Soon;Yoo, Eun Sun;Kim, Hae Soon;Son, Se Jeong;Park, Eun Ae;Lee, Seung Joo;Sung, Sun Hee;Seo, Jeong Wan
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.466-472
    • /
    • 2002
  • Purpose : The diagnosis of Meckel's diverticulum is difficult and delayed because it presents with various clinical symptoms. We evaluated clinical, imaging and pathologic findings of Meckel's diverticulum to facilitate detection of Meckel's diverticulum in children. Methods : Review of clinical, imaging, surgical and pathological findings in 10 children aged 7 days to 14 years with Meckel's diverticulum during an 8-year period, 1993-2001, at Ewha Womans University Hospital was undertaken. Results : The male to female ratio was 2.3 : 1. The chief complaint was painless lower gastrointestinal( GI) bleeding; others were abdominal pain, abdominal distention and vomiting, in order of frequency. The diagonsis before surgery were Meckel's diverticulum in 5 patients, non-reducible intussusception in 3 patients and intestinal obstruction in 2 patients. The diverticulum was located between 35 cm to 70 cm proximal to the ileocecal valve. The length of the diverticulum ranged from 4 cm to 12 cm and 80% of it was within 5 cm. A Meckel scan($^{99m}Tc-pertechnetate$ scintigraphy) after cimetidine administration was done in 6 cases. All 5 cases that presented with lower GI bleeding had ectopic gastric mucosa confirmed on pathology. Out of 5 cases of ectopic gastric mucosa, only 4 cases were positive on the Meckel's scan. Conclusion : In cases of unexplained GI bleeding, obstruction, or inflammation diagnostic workup should be carried out to rule out Meckel's diverticulum. Laparoscopy, high resolution ultrasonography and computed tomography of the abdomen may be indicated in the assessment of pediatric patient with lower GI bleeding, especially in patients with suspected bleeding from Meckel's diverticulum showing negative Meckel's scan.

Cardiovascular Effects of Free Movement of Abdominal Muscle in Prone Positioning during General Anesthesia (전신마취동안에 복와위시 자유로운 복근 움직임이 심혈관계에 미치는 영향)

  • Kim, Ji-Yoon;Lee, Dong-Won;Seo, Il-Sook;Kim, Sae-Yeon
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.206-215
    • /
    • 2007
  • Background : The prone position is often used for operations involving the spine and provides excellent surgical access. The complications associated with the prone position include ocular and auricular injuries, and musculoskeletal injuries. In particular, the prone position during general anesthesia causes hemodynamic changes. To evaluate the cardiovascular effects of the prone position in surgical patients during general anesthesia, we investigated the effects on hemodynamic change of the prone position with the Jackson spinal surgery table. Materials and Methods : Thirty patients undergoing spine surgery in the prone position were randomly selected. After induction of general anesthesia, intra-arterial and central venous pressures (CVP) were monitored and cardiac output was measured by $NICO^{(R)}$. We measured stroke volume, cardiac index, cardiac output, mean arterial pressure, heart rate, CVP and systemic vascular resistance (SVR) before changing the position. The same measurements were performed after changing to the prone position with the patient on the Jackson spinal surgery table. Results : In the prone position, there was a significant reduction in stroke volume, cardiac index and cardiac output. The heart rate, mean arterial pressure and CVP were also decreased in the prone position but not significantly. However, the SVR was increased significantly. Conclusion : The degree of a reduced cardiac index was less on the Jackson spinal surgery table than other conditions of the prone position. The reduced epidural pressure caused by free abdominal movement may decrease intraoperative blood loss. Therefore, the Jackson spinal surgery table provides a convenient and stable method for maintaining patients in the prone position during spinal surgery.

  • PDF

Clinical Effects of Prothinoamide, Cycloserine, Para-Aminosalicylic Acid, Ofloxasine in Retreatment of Pulmonary Tuberculosis (폐결핵 재치료 환자에서 Prothionamide, Cycloserine, Paraminosalicylic acid, Ofloxasine을 이용한 경구 4제 요법의 임상 효과)

  • Hong, Jae-Rak;Yoo, Min-Kyu;Jeong, Jae-Man;Kim, Young-Jun;Son, Mal-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.693-700
    • /
    • 1996
  • Background : Antituberculous therapy is set a short-term therpy used isoniazid(INH), rifampin(RFP), ethambutol(EMB), pyrazinamide(PZA) from 1970s' and treatment rate has been very improved. But drug interruption or irregular medication due to side effects and resistance of drug are serious problem to retreatment cases, specially. Ofloxasine(OFX), developed from Quinolone at 1980's is effective not only other respiratory infectious disease but also pulmonary tube rculosis. And this is useful drug instead of injection agents for retreatment patients who have side effects to other drugs, lived far distance from medical clinics. So, we will evaluate theffectiveness as four oral drugs involving OFX. Method : A retrospective study was made through the regular follow up of smear positive cases,who treated by four drug, namely, prothionamide (PTA) cycloserine(CS), OFX, paraminosalicylic acid(pAS). Results: 1) Out of 66case with positive sputum AFB smear, 42(64%)cases achieved the negative conversion. 2) Considering the negative conversion in all group, 34 case (52%) of sputum conversion occured within first 6 months, on the extent of diease was minimal, moderate, far advanced pulmonary tuberculosis, sputum AFB smear negative response to treatment was 100%, 78%, 46% respectively. 3) The roentgenological improvement occured in 38(58%), extent of diease was minimal, moderately, far advanced pulmonary tuberculosis, Roentgenological improvement to retreatment was 75%, 64%, 46%. 4) When the drnation of patients illness was less than 1 year, 1 to 3 years, 3 10 5 years and more than 5 years, sputum AFB smear negative response to retreatment was 100%, 88%, 80%, 52 %. 5) On side effects, major problems are gastrointestinal troubles, mild liver function abnormality, psychotic problemes, and skin problem(urticaria, itching sensation). Conclusion : The duration & extents of patients illness was shorter & minimal, sputum AFB smear negative response rate was better. Radiologic response is better as shorter duration and minimal extent of diease. But, as diease is longer duration & far advanced, sputum negative conversion & Roentgenological improvement is poor and limited. The adverse reaction was mainly observed gastrointestinal troubles(indigestion, abdominal pain, nausea, vomiting, diarrhea) and are well controled by symptomatic management in most patients, as regard to tolerance to the secondary drugs.

  • PDF