• Title/Summary/Keyword: 보강형

Search Result 990, Processing Time 0.022 seconds

Estimation of Appropriate Reinforcement Length of Casing for the Pile of Pile Bent System through Numerical Analysis (수치해석을 통한 단일형 현장타설말뚝 외부강관의 적정 보강길이 산정)

  • Yang, Wooyeol;Kim, Wanho;Lee, Kangil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.6
    • /
    • pp.5-15
    • /
    • 2021
  • One of the construction methods applied as a pier foundation type is a single type cast-in-place pile. In applying a pile bent system as a foundation type, the main concern in designing can be said to secure the lateral bearing capacity of pile structure in system. In addition, to increase the rigidity of the pile structure, a method of increasing the lateral bearing capacity by reinforcing the pile structure with a casing has been used. However, although the reinforcing effect and appropriate reinforcing length of casing may vary depending on the soil conditions, there is insufficient studies on this, and for this reason, the entire pile structure in a pile bent system is reinforced with a casing, in the field. In addition, if the length of the entire pile is reinforced with a casing, it may lead to delays in construction and increase in construction costs. That is, in order to more effectively reinforce the pile structure with a casing, it is necessary to study the lateral bearing characteristics of the reinforced pile structure in system. And it should be determined the appropriate reinforcing length of the casing from the evaluated bearing characteristics. Therefore, in this study, the lateral bearing characteristics of piles applied with the reinforcing length of casing for each condition were evaluated through a numerical analysis. And, based on the analysis results, the appropriate reinforcing length of casing was proposed. As a result of the study, it was found that in order to effectively increase the lateral bearing capacity of pile structure, the reinforcing length of casing should be applied twice the influence range of the bending behavior of the pile, 1/β.

Evaluation of Structural Performance of Reinforced Concrete Beams using Hybrid Retrofitting with Groove and Embedding FRP Rod and CFRP Sheet (표면요철 매입형 FRP봉과 CFRP시트를 복합 보강한 철근콘크리트 보의 구조성능 평가)

  • Ha, Gee-Joo;Ha, Young-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.41-49
    • /
    • 2014
  • In this study, experimental research was carried out to evaluate the structural performance of the reinforced concrete beam using hybrid retrofitting with two materials (groove and embedding FRP rod, CFRP sheet) in existing reinforced concrete buildings. Seven reinforced concrete beams, retrofitted groove and embedding FRP rod (NER series) and groove and embedding FRP rod with CFRP sheet (NERL series), and standard specimen (NBS) were constructed and tested under monotonic loading. Design parameters of test specimens are the amount of groove and embedding FRP rod and lapping CFRP sheet. Test results showed that the maximum load carrying capacity of specimens with groove and embedding FRP rod and groove and embedding FRP rod with CFRP sheet (NERL series) were increased the by 12~46% and 22~77% respectively in comparison with the standard specimen NBS. Test specimens NER series were failed with the adhesion slip and concrete cover separation. And test specimens NERL series were failed with the adhesion slip due to the confining effect of lapping CFRP sheet.

A Study for Finding Optimized Cable Forces of Cable Stayed Bridge (사장교 케이블 최적 장력 보정에 관한 연구)

  • Park, Dae-Yong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.1
    • /
    • pp.16-20
    • /
    • 2012
  • During construction of the cable-stayed bridge, not only shape of deck and pylon but also cable forces are main factors for geometry control. Especially, geometry control of deck must be controlled for adjusting design value of vertical and lateral alignment as well as closing of key segment. Also, both the deck level error and cable force error occur necessarily during the construction stage in cable stayed bridge. The errors are caused by different of material properties and computer modeling, and construction mistake, and so on. These causes bring about that the forces of cable and the displacement of deck show different tendency from the theoretical values. Therefore, these errors must necessarily be adjusted and can be improved through adjustment of cable length. In this study, a new optimization tool is proposed to adjust the errors of the second Dolsan cable-stayed bridge.

Probabilistic Risk Assessment of a Steel Composite Hybrid Cable-Stayed Bridge Based on the Optimal Reliabilities (최적신뢰성에 의한 강합성 복합사장교의 확률적 위험도평가)

  • Yoon, Jung Hyun;Cho, Hyo Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.395-402
    • /
    • 2007
  • Probabilistic risk assessment was conducted on a hybrid cable-stayed bridge consisting of a steel-composite plate girder and a concrete girder with a long span, designed using the working stress design and strength design methods. The component reliabilities of the bridge's cables, pylons, girders, and steel-concrete conjunction were evaluated using the AFOSM(Advanced First Order Second Moment) algorithm and the simulation technique at the critical sections, based on the maximum axial force, shear, and positive and negative moments of the selected sections. For the analysis of system reliability, the hybrid cable-stayed bridge consisting of cables, pylons, and plate girders was modeled into combined failure modes, and for system reliability, the probabilities of failure and reliability index of the structural system were evaluated. Based on the results of this study, the critical failure modes of the hybrid cable-stayed bridge based on the bridge's structural characteristics are suggested, and the efficiency of the partial ETA technique for use in the risk assessment method was confirmed.

A Study on Compressive Force of Reinforced Grout at the Fixed head of Compression Anchor (압축형 앵커의 선단정착부 그라우트 보강에 따른 산정에 관한 연구)

  • 임종철;이태형;홍석우
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.213-226
    • /
    • 2000
  • 지반 앵커(이하에서는 "앵커"로 칭한다)는 앵커두부, 자유부, 정착부로 나누어져 있다. 현재 주로 사용되고 있는 앵커는 지반과 앵커체 표면의 마찰저항력에 의해 지지하는 마찰방식이며, 앵커체에 발생하는 응력에 따라 크게 인장형과 압축형 앵커로 나누어진다. 그런데, 현재까지 이들 앵커의 설계 및 극한하중의 결정은 대부분이 인장형 앵커에 대한 것으로서, 긴장시 압축형 앵커의 선단정착부의 응력집중으로 이한 그라우트 압축저항에 대해서는 명확히 연구되어져 있지 않다. 본 연구에서는, 현장과 비슷한 조건에서 실내시험을 실시하여 선잔 장착부 그라우트의 보강형식에 따른 압축거동특성과 보강효과, 지반의 구속(정지와 포아송 구속)을 고려한 압축형 앵커의 선단 정착부 그라우트 압축저항력 산정식을 제안하였다.정식을 제안하였다.

  • PDF

Evaluation of Shear Capacity of Wide Beams Reinforced with GFRP and Steel Plates with Openings by Various Supporting Areas (지지부 조건에 따른 유공형 판으로 전단보강된 넓은 보의 전단성능 평가)

  • Kim, Heecheul;Ko, Myung Joon;Kim, Min Sook;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.269-275
    • /
    • 2016
  • In this paper, shear performance of concrete wide beams was evaluated through shear failure tests. The specimens were designed to have two continuous spans with a column at the center of the wide beam. Also the specimens were reinforced with plates with openings as shear reinforcements. For the test, total eight specimens, including five specimens were reinforced with steel plates and the other three specimens were reinforced with GFRP plates were manufactured. And the shear strengths obtained from the tests were compared with ones from the equation provided by ACI 318. Support width of wide beam, support section of wide beam and shear reinforcement material were considered as variables. The results showed that the support width was proportional to the increase of shear strength. Also, regardless of material type of shear reinforcement, the shear reinforcing effect was similar when the amount of shear reinforcement was the same.

Evaluation of Bond Behavior of Reinforced Concrete Beams with High-Strength Transverse Reinforcement (고강도 횡보강근을 사용한 철근콘크리트 보의 부착 거동 평가)

  • Kim, Sang-Woo;Kim, Young-Sik;Baek, Seung-Cheol;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.102-109
    • /
    • 2010
  • This paper investigates the bond behavior of reinforced concrete beams having high-strength transverse reinforcement. A total of four reinforced concrete beams were tested in this study to estimate the bond capacity of the proposed U-shape reinforcement. The proposed U-shape reinforcement not only has a simple structure to install, but also can increase the bond capacity of reinforced concrete beams by controling bond cracks. This study follow the test method proposed by Ichinose to obtain the bond stress and the bond slip of the specimens. The main test parameters were the yield strength, ratio, and reinforcing types of transverse reinforcements. It was found that the proposed U-shape reinforcement was able to effectively improve the bond performance of reinforced concrete beams with high-strength transverse reinforcement.

Reinforcement Method of a Long Span Plastic Greenhouse using Tension-tie (인장타이를 이용한 광폭형 비닐하우스의 보강법)

  • Shin, Kyung-Jae;Shin, Dong-Hui;Lee, Swoo-Heon;Chae, Seoung-Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • A long-span (more than 8m) plastic greenhouse is currently being used in farms due to its magnified benefits, such as the convenience of the farming equipment used, and the land usage efficiency. In this study, the reinforcing effects of the use of a pretension tie were shown. In a previous study, tests for a 6.5m single-span-type greenhouse announced by Rural Development Administration were carried out. The tests of symmetric and eccentrics now loading by the sun and wind were conducted for the 10.2m span with a ${\phi}48.1{\times}2.1$ section in this study, after which the load-deflection relationship was compared for the cases of reinforcement with a tie and without a tie. The results of the symmetric snow loading test showed that the strength increased by 68~93% in the case of the specimen with a tied arch. The failure mode of the specimen without a tie tended to be that with a sway failure mechanism, and that of the reinforcement specimens with a tie tended to be that with an arch buckling mechanism. The results of the eccentric snow loading test showed that the strength of the specimen with a tie increased by 10~20% compared to that of the specimen without a tie. For the failure mode of the latter, a combined failure mechanism was adapted, although the failure mode of the tied specimens tended to be that with an arch buckling mechanism.

Extended Beam Analysis for Compound Rotorcraft Fuselage Design (복합형 회전익 항공기 동체 설계를 위한 확장된 보 해석)

  • Park, Sunhoo;Im, Byeonguk;Chun, TaeYoung;Yeom, Jewan;Shin, SangJoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.9
    • /
    • pp.671-680
    • /
    • 2020
  • This paper describes an improved beam analysis for compound rotorcraft fuselage design. The present beam approach is capable of analyzing fuselage composed of stiffeners using equivalent layer methodology. Thickness of the skin and laminated layer approach are suggested based on the unified beam formulation. The analysis which considers an equivalent stiffener layer is performed for a fuselage with stiffeners and preliminary study about the specification of stiffeners is conducted and compared by the results using the existing software.

An Experimental Study for Reinforcement Effect of Adhesive Stiffeners Depending on the Aspect Ratio of Masonry Wall (조적벽체의 형상비에 따른 접착형 보강재의 보강효과에 관한 실험적 연구)

  • Park, Byung-Tae;Kwon, Ki-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.13-20
    • /
    • 2017
  • Unreinforced masonry buildings are vulnerable to lateral forces, such as earthquakes, owing to the nature of the building materials, yet numerous masonry buildings remain in South Korea. Since the majority of the existing masonry buildings were constructed more than 20 years ago, it is necessary to develop economical reinforcement methods for disaster reduction. In this study, external reinforcement of masonry walls using adhesive stiffeners was proposed as a reinforcement method for such age-old masonry buildings. Six specimens were fabricated with different aspect ratios (L/H = 1.0, 1.3, and 2.0) and used in static load tests to verify the reinforcement effect. The experimental results showed that the masonry walls before and after reinforcement were ruptured by rigid body rotation and slip. In addition, the maximum strength, maximum displacement, and dissipated energy of the walls were shown to increase after applying the adhesive stiffeners, thereby verifying the excellent reinforcement effect. Furthermore, an adhesive stiffener design for unreinforced masonry walls was proposed based on the increased shear strength achieved by using conventional glass fibers. The proposed design can be used as a basis for the application of adhesive stiffeners for unreinforced masonry walls.