• 제목/요약/키워드: 보강철근

검색결과 1,152건 처리시간 0.024초

탄소섬유시트로 보강된 철근콘크리트 보의 시공불량시 휨 거동에 관한 연구 (A Study on Flexural Behavior of Externally Reinforced R.C. Beam with Carbon Fiber Sheet : In Case of Constructional Deficiencies)

  • 박현정;이홍주;박성수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.95-102
    • /
    • 2002
  • The flexural behavior of the reinforced concrete (RC) structure upgraded by external reinforcements was examined in this study. It is well known that the incorporation of carbon fiber sheet (CFS) with concrete is one of the most effective ways to strengthen the RC structure. Complete bonding is required between CFS and concrete in order to make the RC structure provide its full function until the time the Re structures serve. Many studies have reported that construction deficiencies have caused the debonding of the CFS from concrete before the RC structure with CFS reaches its ultimate capacity. This research took a systematic look at the failure mechanism, macroscopic load-deformation characteristics, the maximum load applied, and maximum bending moment when construction deficiencies exist. The results of the experiment conducted were compared with theoretically derived values. In the future, the results of this investigation will help minimize the factors of construction deficiencies, which may occur when CFS is used to reinforce a RC structure. The experiment was manipulated with steel reinforcement ratio and piles of CFS on a total of 14 beams ($20cm{\times}30cm{\times}240cm$). The results showed that internal moment capacity increased even when construction deficiencies existed. However, RC structures with CFS in the field still contain a considerable level of potential risks.

격자형 강합성 바닥판의 수정된 이음부에 대한 휨성능 평가 (Evaluation of the Bending Performance of a Modified Steel Grid Composite Deck Joint)

  • 신현섭;박기태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.38-47
    • /
    • 2013
  • 프리캐스트 방식에 의해 제작이 가능한 격자형 강합성 바닥판의 이음부로서 콘크리트 전단키와 고장력볼트 체결로 구성된 조립식 이음부가 제안된 바 있다. 본 연구에서는 콘크리트 전단키와 고장력볼트로 구성된 이음부의 휨강성과 휨강도를 향상시키고자 단면상세를 개선하였고, 구조실험을 통해 얻은 결과를 기존 볼트체결 이음부와 비교 분석하였다. 비교분석 결과에 의하면, 전단스터드와 가외철근에 의한 이음부 콘크리트 보강으로 뚜렷한 전단균열 감소효과가 있었다. 모멘트-곡률 관계로부터 구한 휨강성을 서로 비교해 본 결과, 단면개선 전의 이음부에 비해 약 47% 정도 휨강성이 증가한 것을 알 수 있었다. 또한, 휨강도 비교결과에 의하면 개선된 이음부의 휨강도는 개선 전에 비해 약 32% 증가하였다. 개선된 이음부의 휨성능을 이음부가 없는 단면과 비교하면, 휨강도의 경우 동등 수준 이상이었으나, 휨강성의 경우는 약 37% 정도 더 작은 것으로 분석되었다.

재생 PET 섬유로 보강된 친환경 황토 콘크리트의 역학적 특성과 휨 거동 (Mechanical Properties and Flexural Behavior of Recycled PET Fiber Reinforced Eco-Friendly Hwang-toh Concrete)

  • 김성배;이나현;김현영;김장호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권3호
    • /
    • pp.152-159
    • /
    • 2010
  • 최근 친환경 재료와 구조물에 대한 관심이 증대되면서 친환경 재료인 황토에 대한 연구가 활발히 진행되고 있다. 황토는 건설 및 마감 재료로 사용된 전통적인 친환경 건설 재료 중의 하나이다. 황토는 높은 축열성, 습도 조절 능력, 자정력, 탈취 및 항균성능, 인체에 유익한 다량의 원적외선이 방사되는 점 등 건설 재료로서 많은 장점을 갖고 있다. 그러나, 황토는 낮은 강도특성과 건조수축 균열 특성 때문에 현대 건설에 사용되지 않고 있는 실정이다. 최근 연구자들의 연구결과에 따르면, 황토는 플라이 애쉬나 포졸란 같은 천연 포졸란 재료로 사용될 수 있다. 본 논문에서는 황토와 슬래그, 재생 PET 섬유가 혼입된 콘크리트의 역학적 성질과 구조적인 휨 거동 실험을 수행하였다. 실험 결과 황토콘크리트의 압축강도와 탄성계수는 기준 시멘트 콘크리트 시편보다 상대적으로 낮게 평가되었으며, 철근 콘크리트 보의 휨 거동은 거의 유사하게 나타났다.

이음철근이 보강된 반단면 프리캐스트 판넬 이음부의 강도 안전성 평가 (Safety Evaluation of the Precast Half Deck Pannel Joints Reinforced by Connection Rebar)

  • 황훈희
    • 한국안전학회지
    • /
    • 제34권2호
    • /
    • pp.40-47
    • /
    • 2019
  • The Half-depth precast deck is a structural system that utilizes pre-cast panels pre-built at the factory as formwork at the construction stage and as a major structural member at the same time after completion. These systems have joints between segments, and the detail and performance of the joints are factors that have a very large impact on the quality, such as the constructability and durability of the bridge decks. In this study, strength performance evaluation was performed for improved joints using connecting rebar by experimental method. Static loading tests were conducted on the test specimen with improved joint, those with existing joint and those without joint. The test results of the specimens were compared to each other, and the flexural strength required by the design was compared. The flexural strength required in the design was presented by finite element analysis. It has been shown that the flexural strength of the specimens with joints were more than twice that required by the design. But the flexural strength of the specimen with existing joint was about 84% of that without joint. The flexural strength of the specimen with improved joints was a nearly similar degree of that compared to the specimen without joint. And a comparison of the moment-deflection relationship curves of the two specimens also shows a very similar flexural behavior. It is confirmed that improved joint has sufficient flexural strength. In addition to strength, the bridge decks require serviceability, such as deflection and cracking, and in particular, fatigue resistance due to repetitive live loads is an important performance factor. Therefore, further verification studies are required.

강섬유 혼입률에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능에 대한 실험적 연구 (An Experimental Study on the Seismic Performance of Reinforced Concrete Exterior Beam-Column Joint with Steel Fiber Volume Fractions)

  • 이장재;배백일;최창식
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.15-23
    • /
    • 2018
  • The purpose of this study is to evaluate the anchorage capacity of longitudinal bars for reinforced concrete exterior beam - column joints with steel fiber volume fractions. For this purpose, the steel fiber volume fraction was set to 0, 1, 2%, and the performance was compared with that of each other specimens. According to the test results, the maximum strength of EX-HK-NJR-0 decreased by 13% compared with the control specimen and EX-HK-NJR-1 decreased by 3% compared to the control specimen. However, when 2% of steel fiber was mixed, the maximum strength increased about 56% compared to the control specimen. The energy dissipation capacity of EX-HK-NJR-0 (when no transverse steel bars are placed) decreased by 61% compared to the control specimen. In addition, the energy dissipation capacity of the specimens with a steel fiber content of 1% decreased by 5% and 2% increased by 94% compared to control specimen. EX-HK-NJR-1,2 and the control specimen EX-HK-JR-0 experienced yielding of the reinforcing bars at the column interface before maximum strength development. However, when the EX-HK-NJR-0, the reinforcing bars at the column interface experienced yielding after maximum strength development. Therefore, reinforcement of steel fiber is considered to reduce the required development length for yielding of steel bars.

2주탑 콘크리트 사장교의 경계조건별 지진 취약도 분석 (Seismic Fragility Analysis by Boundary Conditions of a Two-pylon Concrete Cable-stayed Bridge)

  • 신연우;홍기남;연영모;지상원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.77-85
    • /
    • 2020
  • 본 연구에서는 2주탑 콘크리트 사장교를 대상으로 경계조건에 따른 지진 취약도 곡선을 작성하고, 경계조건이 교량의 지진 취약도에 미치는 영향을 평가하고자 한다. 대상교량에 대한 해석모델이 Midas Civil을 사용하여 구축되었고 Fiber요소와 콘크리트, 철근의 재료모델을 적용하여 비선형 시간이력해석을 수행하였다. 주탑과 보강형 사이의 경계조건을 강결, 비구속, 포트받침, 면진받침의 총 4가지로 구분하여 각각의 경계조건에 대해 지진 취약도 곡선을 작성하였다. 주탑의 소성힌지구간과 연결부, 케이블을 취약부재로 선정하고 이 부재들에 대해 지진 취약도 곡선을 작성하였다. 분석결과 주탑의 소성힌지구간과 연결부에서는 면진받침모델이 가장 낮은 손상확률을 나타내고, 케이블의 지진 취약도는 경계조건에 의한 영향이 다른 부재에 비해 크지 않은 것을 알 수 있다.

터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구 (An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab)

  • 최우진
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.262-269
    • /
    • 2023
  • 연구목적: 터널에서 발생되는 화재로 인하여 구조물의 피해를 보호하기 위해 적용되는 PSC 슬래브에 부착된 내화패널의 성능을 평가할 목적으로 내화실험을 수행하였다. 연구방법: 내화실험은 RWS 화재 이력곡선 화재시간-온도곡선을 적용하였으며, 한국건설기술연구원(KICT)의 가열로를 이용하여 내화 성능을 평가하였다. 연구결과:국제터널학회(2004)에서 제시하는 기준으로 내화성능 실험을 실시한 결과, 내화패널과 콘크리트의 접촉면에서의 최대온도는 콘크리트에 손상을 주는 한계온도(380℃) 이하였으며, 접촉면과 25mm 이격된 지점에서의 최대온도는 철근에 손상을 주는 한계온도(250℃) 이하로 측정되었다. 실험결과로부터, 내화패널이 30mm두께로 부착된 PSC 슬래브 시험체는 내화성능을 가진 것으로 평가되었다. 결론: 터널이나 지하차도에서의 화재발생시 내화패널을 부착하는 보강방법은 화재로부터 구조물을 보호할 수 있으며 향후, 내화패널이 부착된 슬래브의 정적 성능시험을 수행하고, Pull-off test와 피로실험을 실시하여 내화패널의 부착성능을 확인하는 것이 필요하다.

보수/보강 효과를 고려한 철근콘크리트교량의 내진응답해석 (Earthquake Response Analysis of a RC Bridge Including the Effect of Repair/retrofitting)

  • 이도형;조규상;전정문
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.611-622
    • /
    • 2008
  • 보수된 교량 교각의 보수 후의 내진응답 거동을 검토하기 위하여 보수요소를 이용하여 교각 및 교량구조물에 대한 비선형해석을 수행하였다. 본 연구목적을 위하여 단순화된 CFRP 재료의 응력-변형률 모델을 제안하였다. 본 연구에서 제안된 해석기법 및 모델링을 포함한 교각의 해석결과는 강도와 강성에 있어서 실험결과와 만족할 만한 상관관계를 나타내었다. 또한, 교각의 보수효과가 교량전체구조물에 미치는 영향을 검토하기 위하여 다양한 연속지진하중 조합을 작용시켜 교량구조물의 동적시간이력해석을 수행하였다. 이 해석에서는 교각의 이론적인 소성힌지 구간을 CFRP와 강판피복으로 보수하였고, 비교해석결과는 보수 후의 응답을 위해 보수효과를 직접적으로 반영한 해석의 필요성을 입증해 주었다. 결론적으로 본 연구에서 제안된 해석기법 및 모델은 손상된 구조물의 내진보수와 관련하여 유용한 정보를 제공해 줄 수 있을 것으로 사료된다.

화재에 의한 터널구조물 시공재료의 손상 평가 (Evaluation of Fire-induced Damage to Structural Members in Tunnels)

  • 장수호;최순욱;권종욱;배규진
    • 대한토목학회논문집
    • /
    • 제26권3C호
    • /
    • pp.219-228
    • /
    • 2006
  • 본 연구에서는 화재시나리오에 따른 터널구조물의 시공재료별 단면손실과 폭렬현상을 파악하고자 터널구조물 시공재료별로 시험체를 제작한 후 모의 화재시험을 수행하였다. 시공재료별로 화재시험을 수행한 결과, 모든 시공재료에서 RABT 화재곡선보다 RWS 화재곡선에서 단면손실이 다소 크게 발생하였다. 특히, RWS 화재곡선에서 나타나는 $1,200^{\circ}C$ 이상의 고온으로 인한 융해는 시공재료의 단면손실에 주요한 영향요인으로 작용하였다. 철근 보강 구조물은 무근 구조물에 비해 단면손실이 적은 것으로 나타났다. 숏크리트의 경우 화재 시나리오에 따른 단면손실의 차이가 가장 크게 발생하였다. 가열시험 도중에 가열면을 실시간 관찰한 결과, RABT에서의 재료 손상은 폭렬과 탈락에 의해 발생한 반면 RWS에서는 초기에는 RABT와 유사하나 가열개시후 약 50분 이후의 재료 손상은 폭렬과 탈락이 아닌 융해에 의한 것을 알 수 있었다.

Hydrodemolition에 의한 콘크리트 파쇄기준 제안을 위한 실험적 연구 (Experimental Study for Proposal of Concrete Removal Standard using Hydrodemolition Method)

  • 정원경;김기헌;윤경구;김용곤
    • 대한토목학회논문집
    • /
    • 제29권1D호
    • /
    • pp.73-80
    • /
    • 2009
  • 열화된 콘크리트 구조물 보수에 있어, 보수재를 사용하기 전에 열화부위는 완전히 제거되어야 한다. 워터제트 공법은 열화된 콘크리트를 제거하는 방법 중에 하나로 철근 및 건전한 콘크리트에 손상을 주지 않으면서 손상된 콘크리트를 제거할 수 있는 매우 효과적인 방법으로 알려져 있다. 이러한 워터제트의 사용은 표면요철형성 등으로 신구 콘크리트의 부착력을 향상 시킨다. 본 연구에서는 국내에서 적용되고 있는 워터제트 장비를 사용하여 콘크리트 슬래브 강도에 변화를 주어 파쇄깊이에 따른 강도추정식을 제안하고 하였으며 이를 통해 워터제트 관련 규정제안 및 보수보강 시 사용되고 워터제트 장비에 대한 기초적인 정보를 제공하고자 한다.