• Title/Summary/Keyword: 병류

Search Result 44, Processing Time 0.023 seconds

Separation of Phenol from Waste Water (모사폐수로부터 페놀의 분리)

  • 한성록;유홍진
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.11a
    • /
    • pp.283-286
    • /
    • 2002
  • 막-용매 추출을 이용하여 모사폐수로부터 페놀을 분리하였으며, 이때 미세기공 비친수성 중공사형 모듈을 사용하였다. 전체적인 시스템은 향류, 및 병류로 운영되었으며, 유기오염물은 tube 안쪽으로, 용매는 shell쪽으로 흐르게 하였다. MIBK를 추출용매로 사용하였으며, 페놀의 분리효율은 향류 흐름이 병류흐름보다 더 우수함을 알 수 있었다.

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

Separation of Organic Pollutants by Nondispersive Membrane-Solvent Extraction (비분산 막-용매추출에 의한 유기오염물의 분리)

  • 유홍진;한성록
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.2
    • /
    • pp.174-185
    • /
    • 2004
  • Organic pollutants (Phenol, 2-Chlorophenol, Nitrobenzene) were separated from wastewater by nondispersive membrane solvent extraction, using a microporous hydrophobic hollow fiber module. The system was operated countercurrently and cocurrently with the aqueous phase flowing through the fiber lumens and the solvent flowing through the shell side. The distribution coefficients of several solvents (MIBK, IPAc, Hexane) were examined and MIBK was selected as an extracting solvent. Separation efficiency of countercurrent flow method was better than that of cocurrent flow method. Also, the overall mass transfer coefficients were determined.

  • PDF

Removal of Organic Pollutants from Aqueous Solution by Hollow Fiber Module (중공사모듈에 의한 수용액으로부터 유기오염물의 제거)

  • 유홍진
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.2
    • /
    • pp.114-119
    • /
    • 2003
  • This study is to remove several organic pollutants from wastewater by non-dispersive membrane solvent extraction technique. The distribution coefficients of several solvents were determined and the experimental system was operated counter-currently and cocurrently with respect to the aqueous phase and solvent. In these experiments, as the flow rate of aqueous solution inclosed, due to being shortened contact time to solvent, the rate of removal of organic pollutants decreased and as the flow rate of solvent increased, the rate of removal increased. Meanwhile, the rate of removal of organic pollutants for the countercurrent flow system was higher than that for the occurrent flow system.

  • PDF

A Literature Review on Korean Rice-cakes (한국(韓國) 떡에 관한 문헌적(文獻的) 고찰(考察))

  • Lee, Cherl-Ho;Maeng, Young-Sun
    • Journal of the Korean Society of Food Culture
    • /
    • v.2 no.2
    • /
    • pp.117-132
    • /
    • 1987
  • A literature survey on traditional Korean rice-cakes was made in order to identify the historical background and the state of scientific understanding on these products. Korean rice cakes can be classified into 5 groups depending on the processing methods; steamed (Jeung-byung), pounded (Do-byung), shaped and steamed or boiled (Dan-ja), fried (Yu-Jeon-byung) and fermented and steamed (Yi-byung). They are further divided into varieties by the raw materials used, coating materials and shape. The recipe and processing characteristics of 5 groups of Korean rice-cake were discussed and the scientific findings on these products were reviewed.

  • PDF

Estimation of the Bulk Density for Recyclable Residential Wastes (폐기물 관리시설 설계를 위한 재활용성 생활폐기물의 겉보기밀도 평가에 관한 연구)

  • Kim, Byung-Tae;Kim, Myeong-Woon;Lee, Chang-Hae
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.102-107
    • /
    • 2017
  • To estimate the bulk density applying the composition rate for recyclable residential waste, the composition rates by volume and weight basis, the bulk densities of the separated and commingled wastes were investigated four times respectively for recyclable waste of 1,800 kg transported to waste recovery facility. The bulk densities for separated wastes were $379.0kg/m^3$ of glass bottles that is highest and metals, residues, others, cans, plastics in order. The composition rates for each separated waste were changed widely depending on either volume basis or weight basis. The composition rate by weight basis as 40.6% of the glass bottles, 32.6% of the plastics were changed to 60.2% of the plastics and 8.9% of the glass bottles in that by volume basis. The bulk density of the commingled wastes applying the composition rate by volume basis showed the similar value to the measured density than by weight basis. So it was estimated that the composition rate by volume basis was appropriate for determining the bulk density of the commingled recyclable wastes.

Modelling and Simulation of H2 separation in Pd Membrane System with Co-current and Current-current Flow (병류와 향류 흐름에서 수소분리를 위한 Pd 분리막 시스템의 모델링 및 모사)

  • Yi, Yong;Noh, Seunghyo;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.598-602
    • /
    • 2010
  • In this paper, we carried out CFD modelling and simulation for the membrane system to separate H2 gas from the multi-component feed gas. The membrane system is of the annulus tubular type consisting of the external lumen side for the feed gas and the internal permeation side for the sweeping gas. The operating temperature and pressure of the lumen side inlet flow are $374^{\circ}C$ and 7 bar respectively and those of the sweeping gas are $374^{\circ}C$ and 3 bar, and considering these conditions, Pd membrane system was employed. CFD simulations were performed for the co-current flow and counter-current flow membrane system based on the flow directions between the feed and the sweeping gas. Comparisons and discussions were made for the H2 partial pressure, H2 mole fraction and H2 flux for both cases. Furthermore, we executed CFD simulations for the each case of the various inlet flow rates of the feed gas at the lumen side. Accordingly, we reviewed the effects of the flow rate and residence time on the performance of the membrane system.

Separation and Recovery of Indole from Model Coal Tar Fraction by Batch Cocurrent 5 Stages Equilibrium Extraction (회분 병류 5단 평형추출에 의한 모델 콜타르 유분 중에 함유된 Indole의 분리 및 회수)

  • Kim, Su Jin;Chun, Yong Jin;Jeong, Hwa Jin
    • Applied Chemistry for Engineering
    • /
    • v.18 no.2
    • /
    • pp.168-172
    • /
    • 2007
  • The separation of indole from a model mixture comprising four kinds of nitrogen heterocyclic compounds [indole (In), quinoline (Q), iso-quinoline (iQ), quinaldine (Qu)], three kinds of bicyclic aromatic compounds [1-methylnaphthalene (1MN), 2-methylnaphthalene (2MN), dimethylnaphthalene (DMN)], biphenyl (Bp) and phenyl ether (Pe) was examined by batch cocurrent 4 stages equilibrium extraction. The model mixture used as a raw material in this work was prepared according to the components and compositions contained in coal tar fraction (the temperature ranges of fraction: $240{\sim}265^{\circ}C$). An aqueous solution of formamide was used as a solvent. Indole was recovered more than 99% through 4 stages of the equilibrium extraction. The range of selectivity of indole in reference to DMN obtained through the 5 stages equilibrium extraction was found to be 63~118. The process for separation and recovery of indole contained in coal tar was studied by using the experimental results obtained from this work and the previous work.