• Title/Summary/Keyword: 병렬인버터

Search Result 232, Processing Time 0.03 seconds

Development of a Parallel Inverter for 2 MW Windpower Generator (2 MW 풍력발전기용 병렬형 Inverter 개발)

  • Choi, Hyo-Jin;Kwon, Sei-Jin;Son, Yoon-Gyu;Suh, Jae-Hak;Jang, Sung-Duk;Oh, Jong-Seok;Kang, Sin-Il;Lee, Hyun-Young;Kwon, Oh-Jung;Lee, Byung-Chul;Hwang, Jin-Su;Ryu, Ji-Yoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.427-431
    • /
    • 2007
  • 본 논문에서는 750 kW 풍력발전용 인버터를 개발한 결과와 2년 동안의 현장실증을 통하여 얻어진 경험을 바탕으로 2 MW 영구자석형 동기발전기(PMSG, Permanent Magnet Synchronous Generator)의 전력변환을 위한 병렬형 인버터의 시뮬레이션과 이를 통한 설계와 제작 및 기본시험 과정을 소개하고자 한다.

  • PDF

Parallel Inverter Development for 2MW Windpower (2MW 풍력발전기용 병렬형 Inverter 개발)

  • Lee, Hyun-Young;Kang, Sin-Il;Kwon, Oh-Jung;Choi, Hyo-Jin;Kwon, Sei-Jin;Son, Yoon-Gyu;Suh, Jae-Hak;Jang, Sung-Duk;Oh, Jong-Seok;Lee, Byung-Chul;Hwang, Jin-Su;Ryu, Ji-Yoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.336-340
    • /
    • 2007
  • 본 논문에서는 750kW 풍력발전용 인버터를 개발한 결과와 2년 동안의 현장실증을 통하여 얻어진 경험을 바탕으로 2MW 영구자석형 동기발전기(RMSG, Permanent Magnet Synchronous Generator)의 전력변환을 위한 병렬형 인버터의 시뮬레이션과 이를 통한 설계와 제작 및 기본시험 과정을 소개하고자 한다.

  • PDF

A Characteristic Improvement for the Parallel operation of Z-source Inverters (Z-소스 인버터의 병렬 운전 특성 개선)

  • Kim Y.H.;Mun Hyeon-Uk;Lee W.Y.;Seo K.M.;Won C.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.281-284
    • /
    • 2006
  • 본 논문에서는 연료 전지 시스템을 위한 Z-소스 인버터로 구성된 병렬 운전 시스템을 제시 하였다. PWM 방식으로는 Carrier phase shifted SPWM을 적용하였으며 이 방식은 출력 전류의 고조파 성분을 줄일 수 있는 장점을 갖는다. 그러나 이 기법을 Z-소스 인버터로 구성된 병렬 운전 시스템에 적용하는 경우 추가적으로 순환 전류를 발생한다. Z-소스 인버터로 구성된 병렬 운전 시스템이 동작 시 발생하는 순환 전류를 감소시키며, 부하전류에 낮은 고조파 성분을 가질 수 있도록 커플링된 순환 전류 리액터를 사용하였다. 이에 대한 적합성을 시뮬레이션을 통해 입증하였다.

  • PDF

Sensorless Drive for Mono Inverter Dual Parallel Surface Mounted Permanent Magnet Synchronous Motor Drive System (단일 인버터를 이용한 표면부착형 영구자석 동기전동기 병렬 구동 시스템의 센서리스 방법)

  • Lee, Yongjae;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.243-244
    • /
    • 2014
  • 본 논문은 단일 인버터를 이용하여 두 개의 표면부착형 영구 자석 동기 전동기를 위치, 속도 센서 없이 구동하는 방법을 소개한다. 기존에 두 개의 동기전동기를 병렬 구동하기 위해서는 위치센서를 반드시 필요로 하였다. 때문에 가격을 절감할 수 있다는 단일 인버터를 이용한 병렬 전동기 구동 시스템의 장점이 퇴색되었다. 본 논문에서는 단일 인버터를 이용한 병렬 전동기 구동 시스템의 센서리스 구동을 위한 새로운 구동 방법 및 제어 전략을 소개하고 실험을 통해 이를 검증하였다.

  • PDF

Virtual impedance based droop method for high-capacity parallel inverters under unbalanced line impedances (불평형 라인 임피던스를 가진 고용량 병렬형 인버터 구동을 위한 가상임피던스 기반의 드룹제어)

  • Lim, Kyungbae;Ko, Seungwoo;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.83-84
    • /
    • 2015
  • 본 논문에서는 무효전력 오차를 야기하는 유도성-저항성 복합성의 불평형 임피던스 선로 하에서 가상 인덕터와 가상 저항을 사용한 드룹 제어 기반의 병렬형 인버터 시스템에 관해 다루고 있다. 여기서 무효 전력 분담 에러는 각 선로 임피던스의 전압 강하를 고려함에 따라 개선 가능하다. 그러나 병렬형 인버터 시스템이 고전류, 고용량일 경우 지령 출력 전압 크기는 정격 전압 크기에 미치지 못하게 되며 이는 가상 인덕터 및 저항값과 출력 전류의 곱을 통한 가상 임피던스의 전압강하 산출법에 기인한다. 이러한 이유로 본 논문에서는 기존의 드룹 방식에 선로 임피던스 전압 강하 뿐만 아니라 가상 임피던스의 전압 강하도 추가되었고 이를 통해 병렬형 인버터의 전압 출력이 정격 출력값의 범위 안에서 구동하도록 하였다. 가상 인덕터와 가상 저항의 적용법에 대한 비교에 기반을 둔 제안된 드룹 방식은 PSIM 시뮬레이션을 통해 검증되었다.

  • PDF

Quasi-Parallel Resonant DC-link Inverter with One Additional Switching Device (하나의 추가 스위칭 소자를 갖는 유사병렬 공진형 DC-link 인버터)

  • 정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.170-175
    • /
    • 2000
  • A new quasi-parallel resonant DC link inverter is proposed for three phase soft switching application. By i inserting only one additional switch, the proposed inverter excludes both voltage stresses and restricted PWM p problems, which are demerits of the conventional resonant inverter. In this paper, the circuit operations are e explained in detail using the operational mode analysis of the proposed inverter and design methods of the r resonant components are suggest('x:l. Lastly, the applicable possibility of the proposed inverter is vel예fied t through the experimental results.

  • PDF

SVC coupled UPQC for reactive power compensation capacity increase and DC link voltage reduction (무효전력 보상 용량 증대 및 DC 링크 전압 저감을 위한 SVC 결합형 UPQC)

  • Pyo, Soo-Han;Park, Jang-Hyun;Oh, Jeong-Sik;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.99-106
    • /
    • 2019
  • This paper propose a new form of UPQC (Unified Power Quality Compensator) to compensate the current and voltage quality problems of nonlinear loads. The conventional UPQC system consists of a series inverter, a parallel inverter, and a common DC link. A new type of UPQC proposed is a parallel compensator with SVC (Static Var Compensator) added to compensate for the wide compensation range and low DC link voltage. The parallel inverter compensates the reactive power generated by the nonlinear load, and the series inverter compensates the sag and swell generated at the power supply side.

The Study of 80VMA UPFC operation (80MVA UPFC 운전 결과 분석)

  • Kim, S.Y.;Yoon, J.S.;Jeon, Y.S.;Park, C.S.;Yoo, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.416-418
    • /
    • 2003
  • 한국전력공사에서는 전압원 인버터형 FACTS 기기인 UFPC를 전남 강진군 강진변전소에 설치하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병럴인버터, 40MVA 직렬인버터로 구성되어 총 80MVA 용량이다. 강진 UPFC는 GTO를 이용한 3레벨 인버터 모듈 20MVA 총 4대로 구성되어 있으며, STATCOM, SSSC, UPFC의 3가지 운전모드를 갖는다. 현재 병렬인버터는 강진 모선전압 제어, 직렬인버터는 강진-장흥간의 조류제어에 기여하며, 상용운전 중이다. 본 논문에서는 강진 UPFC의 운전결과 및 효과를 분석하였다.

  • PDF

Switching acoustic noise & thermal loss reduction method through power circuit parallel construction of electric vehicle propulsion inverter (전기자동차 구동용 인버터의 전력회로 병렬 구성을 통한 스위칭 소음 및 손실 저감 방법)

  • Lee, Jong-Chan;Hong, Sung-Min;You, Doo-Young;Bang, Lee-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.370-371
    • /
    • 2013
  • 최근 계속되는 유가 상승과 화석에너지의 고갈 문제, 그리고 환경에 대한 관심 증가로 인해 자동차의 연비 개선 및 배기가스 저감을 위한 친환경 자동차 기술로 전기자동차에 대한 연구 활동이 활발하게 진행 중이다. 전기자동차에서 동력을 발생시키는 대용량 전동기는 큰 토크 발생에 필요한 전류를 받아들이기 위하여 내부적으로 이중 권선을 갖도록 구성되어 있고, 인버터 전력소자는 대용량 소자를 사용하거나 병렬로 구성하여 전동기 1상의 전류를 감당하도록 되어 있다. 본 논문에서는 전동기의 이중 권선에 인버터의 전력회로를 병렬로 구성하여 6선 3상으로 연결함으로써 전동기에 인가되는 인버터의 PWM 스위칭 주파수를 기존보다 낮게 사용하더라도 스위칭 소음, 전류의 맥동 및 손실을 줄일 수 있는 방법을 제안하였다.

  • PDF

Parallel Operation of Grid-connected Inverters with Seamless transfer for Energy Storage System (에너지저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전)

  • Jung, Ahjin;Kim, Jooha;Prabowo, Yos;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.343-344
    • /
    • 2014
  • 마이크로그리드에서 ESS용 PCS를 모듈화하면 용량의 확장성, 신뢰성 향상 등의 장점을 갖는다. 모듈화 된 인버터는 병렬구조를 갖고 인버터 모듈간의 접속점(PCC)에 공통으로 중요부하를 공유하고 있어 독립운전 시 정확한 부하분담이 요구된다. 또한 독립운전 및 계통연계 모드전환 시 제어기 변동으로 인한 과도상태로 인해 접속점에 연결된 중요부하에 악영향을 끼칠 수 있다. 따라서 본 논문에서는 ESS용 PCS로서 모듈화 된 병렬 인버터가 모드전환 시 과도상태가 없는 무순단 절체 기능을 갖는 마스터-슬레이브 제어알고리즘을 제안한다.

  • PDF