• Title/Summary/Keyword: 변조전달함수(modulation transfer function)

Search Result 84, Processing Time 0.029 seconds

Effects of the Geometrical Misalignment on the MTF Measurement (변조전달함수 측정에 있어 기하학적 조정 불량이 해상도에 미치는 영향)

  • Kim, Jun-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.705-713
    • /
    • 2021
  • The modulation transfer function (MTF) is calculated to analyze the resolution of the spatial frequency of the image acquired from the x-ray imaging system. In general, the response function of the detector acquires a line spread function (LSF) using a slit-camera, and derives a modulation transfer function through a Fourier transform. Because of the fact that the x-ray must always be incident on the center of the slit-camera, the tilt of the detector and slit-camera caused by the experimenter will affect the detector performance. In addition, if the tilt increases, the performance evaluation of the x-ray image system will be problematic. In this study, we analyzed the experimental and analytical models in the modulation transfer function, ie, the Fourier domain, based on the experimental error and analyzed the effect on the spatial frequency. Furthermore, performance evaluation is being carried out for various x-ray imaging systems, and experimental errors are indispensable, and the extent to which they can be tolerated should be reviewed.

Prediction of visual performance using contrast sensitivity function and modulation transfer function (대비감도함수와 변조전달함수를 이용한 시기능 예측)

  • Kim Sang Gee;Park Sung Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.461-468
    • /
    • 2004
  • A finite model eye of visual acuity 24/20 in emmertropia was presented. We determined the image intensity profile on retina using optical transfer function of model eye, and compared with clinical data. The retinal contrast sensitivity function based on the Stiles-Crawford effect, photopic response, diffraction, aberration, retinal contrast sensitivity, and pupil size is calculated. Visual acuity for human eye could be predicted by examining the modulation transfer function of a bar target and retinal contrast sensitivity function. This visual acuity was evaluated for pupil diameters ranging from 1 to 8 mm.

Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom (컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.193-198
    • /
    • 2016
  • In clinical computed tomography (CT), regular quality assurance (QA) has been required. This study is to evaluate the MTF for analyzing the spatial resolution using AAPM phantom in CT exam. The dual source somatom definition flash (siemens healthcare, forchheim, Germany), the brilliance 64 (philips medical system Netherlands) and aquilion 64 (toshiba medical system, Japan) were used in this study. The quantitative evaluation was performed using the image J (wayne rasband national institutes of health, USA) and chart method which is measurement of modulation transfer function (MTF). In MTF evaluation, the spatial frequencies corresponding to the 50% MTF for the CT systems were 0.58, 0.28, and $0.59mm^{-1}$, respectively and the 10% MTF for the CT systems were 1.63, 0.89, and $1.21mm^{-1}$, respectively. This study could evaluate the characteristic of spatial resolution of MTF using chart method, suggesting the quantitative evaluation method using the data.

Evaluation of the Spatial Resolution for Exposure Class in Computed Radiography by Using the Modulation Transfer Function (변조전달함수를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능 평가)

  • Seoung, Youl-Hun
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.273-279
    • /
    • 2013
  • The purpose of the study was to present basic data to evaluation of the spatial resolution for exposure class(EC) in computed radiography(CR) by using the modulation transfer function(MTF). In this study, MTF was measured the edge method by using image plate(IP) of $100{\mu}mm$ pixels. A standard beam quality RQA5 based on an international electro-technical commission(IEC) standard was used to perform the X-ray imaging studies. Digital imaging began to set the sensitivity to EC 50, 100, 200, 300, 400, 600, 800, 1200 in X-ray irradiated to IP. The MTF 50% and 10% in the final images was analysis by using an authorized image analysis program the Origin 8.0 and the image J. As a results, the EC 200 was the best spatial resolution at MTF 50% ($1.979{\pm}0.114lp/mm$) and MTF 10% ($3.932{\pm}0.041$). Therefore, the EC 200 could be useful for the diagnosis of diseases that require high spatial resolution such as fractures.

A Study on the MTF Analysis for the Three Primary Colors of Light within Diffraction-Limitted System (회절제한시스템에 속한 빛의 3원색의 변조전달함수 해석에 관한 연구)

  • Che, Kyu-Shik;Chang, Won-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.863-866
    • /
    • 2012
  • The optical system develops remarkably as well as the development of civilization. The modulation transfer function(MTF) was introduced as one of the important estimation methods to estimate the performance of optical systems. The calculation of MTF is very boring and tiresome. We express the MTF curves three primary colors of light in the diffraction-limitted systems.

  • PDF

Effects of Changes in Equivalence Ratio and Modulation Condition on Flame Transfer Function (당량비 및 섭동 조건 변화가 화염 전달 함수에 미치는 영향)

  • Kim, Dae-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.35-40
    • /
    • 2011
  • An experimental study of the flame response in a turbulent premixed combustor has been conducted in order to investigate mechanisms for combustion instabilities in a lean premixed gas turbine combustor. A lab-scale combustor and mixing section system were fabricated to measure the flame transfer function. Measurements are made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The results show that the flame transfer functions are greatly dependent on the modulation frequency as well as operating conditions such as equivalence ratio. Flame dynamics can be generalized as a function of Strouhal number which is a ratio of flame length to modulation wave length.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.

Study of MTF Measure That Adopts a Fitting Curve for the Variable Angle of a Slant Target in Presampled MTF (Presampled MTF 기법에서 Slant Target의 다양한 각도에 대한 함수 Fitting이 적용된 MTF 측정기법에 관한 연구)

  • Choi, Siyoun;Kim, Junghwan;Kong, Hyunbae;Kim, Donghwan;Baek, Kyounghoon;Park, Ingu;Jeon, Hyowon;Lee, Kinam
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.310-316
    • /
    • 2022
  • In this paper, the difference in modulation transfer function (MTF) results according to the change in the angle of a slant target when measuring a presampled MTF was confirmed, and the difference was reduced by fitting the edge spread function graph obtained to reduce the error by the target's rotation. Due to the feature of the presampled MTF method, the spatial frequency changed due to the sensor's projected intensity being changed by the target's rotation, and it was confirmed that the difference in the MTF value occurred depending on the rotation angle of the target. In this paper, the MTF was calculated after fitting only one column of the acquired image. It was confirmed that the rotation error is smaller compared to the case of the presampled MTF method and this fitting method can be applied to a scene that contains various target angles, such as auto-focusing using the MTF.

Study on combustion instabilities in gas turbine combustors (가스터빈 연소기에서의 연소 불안정 측정에 관한 연구)

  • Kim, Dae-Sik;Lee, Jong-Guen;Santavicca, Domenic
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.430-432
    • /
    • 2011
  • An experimental study of the flame response in a turbulent premixed combustor has been conducted in order to investigate mechanisms for combustion instabilities in lean premixed gas turbine combustor. A lab-scale combustor and mixing section system were fabricated to measure the flame transfer function. Measurements are made of the velocity fluctuation in the nozzle using hot wire anemometry and of the heat release fluctuation in the combustor using chemiluminescence emission. The results are analyzed to determine the phase and gain of the flame transfer function as a function of the modulation frequency and operating conditions.

  • PDF