• Title/Summary/Keyword: 변위특성

Search Result 1,829, Processing Time 0.029 seconds

Analysis of Three-dimensional Water Waves Created by a Hydrofoil Using a Higher-Order Boundary Element Method (고차경계요소법을 이용한 수중익에 대한 3차원 조파문제 해석)

  • Il-Ryong Park;Ho-Hwan Chun;Sung-Hwan Kim;Dong-Dai Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.3
    • /
    • pp.1-13
    • /
    • 1998
  • In the present paper, the hydrodynamic characteristics of three dimensional hydrofoils moving with a constant speed below the free surface using a higher-order boundary element method based on 9-node Lagrangian curvilinear elements are investigated. A bi-quadratic spline scheme is employed to improve the numerical results on the free surface. To validate the present scheme, the calculated results are compared with the analytic solutions for a submerged sphere and a spheroid showing a good agreement. For the validation of the hydrofoil study, the computed lift and drag of a hydrofoil having $NACA64_{1}A412$ section with aspect ratio(A.R.) of 4 are compared with the experimental data by Wadlin et al.[28]. The comparison covers a number of variations of angle of attack and submergence depth. Then, using an A.R. hydrofoil with NACA0012 section, the free surface on the lift and drag are investigated and these are compared with the previous results. The wave elevations and patterns created by the aforementioned submerged bodies are also investigated with Froude numbers and submergences.

  • PDF

Deflection Limit based on Vibration Serviceability of Railway Bridges Considering the Correlation between Train Speed and Vertical Acceleration on Coach (열차의 주행속도와 차체연직가속도의 상관관계를 고려한 철도교량의 진동사용성 처짐 한계)

  • Jeon, Bub-Gyu;Kim, Nam-Sik;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.545-554
    • /
    • 2011
  • In order to get dynamic serviceability of a train travelling on a railway bridge, comfort limits with the deflection of bridge and vertical acceleration on car body are proposed in Eurocode, Shinkansen design criteria, The design guideline of the Honam High-speed railway. The design guideline of the Honam High-speed railway has quoted Eurocode. Therefore it is expected that supplementation of comfort limit of railway bridge according to expansion of span length and the improvement traveling speed of trains in the future would relatively fall behind developed countries in railway. Therefore, in order to secure technological competitiveness in world market, the study was conducted to propose the deflection limit based on vibration serviceability of railway bridges that can consider bridge-train interaction and travelling speed increase. The parameter study and bridge-train dynamic interaction analysis was conducted to figure out the correlation of vertical acceleration on car body and bridge displacement according to the increase in travelling speed. Also, the trend of increasing vertical acceleration on car body according to the increase in travelling speed was confirmed, and the amplification coefficient of vertical acceleration on car body was suggested. And the deflection form and vibration of the bridge were assumed to be in harmonic motion, and transfer function and the amplification coefficient were used to develop the dynamic serviceability deflection limit of the high-speed railway bridge as a formula.

Cyclic Structural Characteristics of Thermal Bridge Breaker Systems embedded in Reinforced Concrete Slabs (벽-슬래브 접합부에 매립된 열교차단장치의 반복하중에 대한 거동특성 평가)

  • Shin, Dong-Hyeon;Oh, Moung-Ho;Kim, Young-Ho;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.511-521
    • /
    • 2015
  • The thermal bridge occurring in a building influences its thermal performance and durability. The domestic typical multi-unit residential buildings suffer thermal losses resulting from thermal bridges of the balcony slab. To minimize the thermal loss between inside and outside of the balcony slab, thermal bridge breaker(TBB) systems have been developed and applied in building construction. Although thermal bridge breaker systems for reinforced concrete(RC) wall-slab joints can improve the thermal performance of a building, it is necessary to verify the structural performance of TBB systems whether they provide proper resistance for cyclic loading. In order to investigate the structural characteristics of TBB systems embedded in RC slabs, cyclic tests of wall-slab joints were performed by applying two reversed cycles at each up to 30 cycles. The test results show that the RC slabs embedding TBBS systems can present excellent structural performance and the maximum moment capacity, energy dissipation capacity and ductility of TBBs systems are enhanced compared to those of the typical RC slabs.

Multi-objective Integrated Optimization of Diagrid Structure-smart Control Device (다이어그리드 구조물-스마트 제어장치의 다목적 통합 최적화)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.69-77
    • /
    • 2013
  • When structural design of a tall building is conducted, reduction of wind-induced lateral displacement is one of the most important problem. For this purpose, additional dampers and vibration control devices are generally considered. In this process, control performance of additional devices are usually investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a tall building with additional smart damping device has been investigated. To this end, a 60-story diagrid building structure is used as an example structure and artificial wind loads are used for evaluation of wind-induced responses. An MR damper is added to the conventional TMD to develop a smart TMD. Because dynamic responses and the amount of structural material and additional smart damping devices are required to be reduced, a multi-objective genetic algorithm is employed in this study. After numerical simulation, various optimal designs that can satisfy control performance requirement can be obtained by appropriately reducing the amount of structural material and additional smart damping device.

Experimental and Analytical Studies on the Non-Linear behaviors of Pre-Stressed Steel H-Beams (프리스트레스트 H형강 거더의 비선형 거동에 대한 실험적 및 이론적 연구)

  • Kim, Moon-Young;Kim, Nak-Kyung;Oh, Yong-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.359-366
    • /
    • 2019
  • Experimental and analytical studies on the behavioral characteristics of a pre-stressed (PS) steel girder are conducted to investigate the effects of deviators on the non-linear inelastic properties of the PS system. In this regard, 4 test specimens consisting of a steel H-beam, a straight cable with eccentricity, anchorages, and deviators are built and failure tests are performed under two-point loading. In addition, in-plane elastic deformation theories for the PS system without a deviator, and with three deviators at regular intervals are analytically formulated and solved using a symbolic calculation technique. To verify the validity of the experimental and the proposed analytical theories, the results obtained using FEM models composed of beam elements, rigid beam elements, and truss cable elements, are compared to the experimental results and the analytical solutions. As a result, it is determined that externally installed un-bonded deviators inhibit flexural deformation of the deformed beam to such an extent that their elastic stiffness, and failure strength are significantly improved compared to those of the PS system without deviators.

Nonlinear Behavior of Seismic-Strengthened Domestic School Building (국내 기존 학교건축물의 내진보강 후 비선형 거동특성)

  • Ryu, Seung Hyun;Yun, Hyun Do;Kim, Sun Woo;Lee, Kang Seok;Kim, Yong Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.243-253
    • /
    • 2011
  • This paper describes an analytical study on seismic performance of domestic reinforced concrete (RC) school building not designed by seismic provision. The seismic index and the seismic performance of the building were evaluated through Japanese standard and Midas Gen, respectively. Seismic index (Is) of the RC school buildings in the X-direction is below 0.4. Based on the seismic index, for seismic-strengthening the building, infill shear wall or steel brace with a capacity of 1,300 kN was used. According to nonlinear static analysis results, the contribution of the seismic-strengthening to the shear resistance of the school building was measured to be greater than 30%. However, as expected, shear strength of school building strengthened with infill wall dropt rapidly after peak load and much narrower ductile behavior range was observed compared to steel brace strengthened building. Also, the building strengthened with steel brace showed 30% larger spectral displacement than that strengthened with infill shear wall. In nonlinear dynamic analysis, for the time history analysis, the maximum displacement showed tendency to decrease as amount of reinforcement increased, regardless of strengthening method. It was recommended that variable soil properties and earthquake record should be considered for improving seismic performance of buildings in seismic zone.

Dynamic Behaviour of Masonry inFilled Reinforced Concrete Frames with Non-Seismic Details (진동대실험을 통한 비내진상세를 가지는 RC 골조의 조적채움벽 유무에 따른 동적 거동 평가)

  • Baek, Eun-Rim;Kim, Kyung-Min;Cheon, Ju-Hyun;Oh, Sang-Hoon;Lee, Sang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.121-129
    • /
    • 2017
  • In this paper, the shake table test for the masonry infilled reinforced concrete frame with non-seismic details was carried out in order to evaluate its dynamic behaviour and damage under seismic condition. The tested specimens were the RC frame and the masonry infilled RC frame and the dynamic characteristics, such as a resonant period, acceleration response, displacement response and base shear force response, were compared between them. As a result of the shake table test, RC frame specimen had flexural cracks at the top and bottom of the column and shear cracks at the joints. In the case of masonry infilled RC frame, the damage of the frame was relatively minor but the sliding cracks and diagonal shear cracks on the masonry wall were severe at the final excitation. The resonant period of infilled RC frame specimen was shorter than that of the RC frame specimen because the masonry infill contributed to increase the stiffness. The maximum displacement response of the infilled RC frame specimen was decreased by about 20% than the RC frame specimen. It was analyzed that the masonry infill wall applied in this study contributed to increase the lateral strength of the RC frame with non - seismic detail by about 2.2 times and the stiffness by about 1.6 times.

Analysis of Seismic Performance of Modular Containment Structure for Small Modular Reactor (소형 원자로용 모듈화 격납구조의 내진성능 분석)

  • Park, Woo-Ryong;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.409-416
    • /
    • 2020
  • The seismic performance of a containment structure should be secured to maintain the structural soundness of a containment structure under various earthquakes that occur globally. Therefore, an analysis of the seismic performance of a modular containment structure for a small modular reactor is also required. To analyze the seismic performance of modular containment, FEM models with contact surfaces between the modules and tendon were prepared and the modal and seismic analyses were performed. The displacement, stress, and gap size of modular containment under earthquake wave were analyzed. The effects of the tendon force, friction coefficient, and earthquake wave on the seismic performance were analyzed. The seismic performance of monolithic containment was also analyzed for comparison. In the 1st and 2nd natural modes, which most likely affect, the modular containment showed horizontal dynamic behavior, which is similar to monolithic containment, because of the combined effects of the tendon force and friction force between modules. When the combined effect is sufficient, the seismic performance of the modular containment is secured over a certain level. An additional increase in seismic performance is expected when some material with a larger friction coefficient is adopted on the contact surface.

The Changes of Coastal Water Level due to the Development of Mokpo Harbor and Construction of Daebul Industrial Complex (목포항 개발 및 대불 산업단지 조성에 따른 연안해역 해면변화)

  • 정명선;이중우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1991.06a
    • /
    • pp.37-44
    • /
    • 1991
  • 영산강 하구언 방조제의 건설로 인한 항만 및 이의 인접해역 해면의 변화는 예상한 바 있으며 실제 여러개소에서 월 2회정도의 주기로 목포 구항부근 상업지역에서 해면상승에 따라 주기적으로 침수되는 현상이 나타나고 있다 목포항의 영산강 하구언 방조제 조성으로 인한 조류성분중 최고기록을 가진 수로에서는 6kts 정도로 감소된 것으로 보고되고 있으나 주위자연환경 변화에 따른 수면 상승 및 해수면의 주기적인 변화 등에 대한 상세한 언급 및 깊이 있는 분석은 회피되어왔다. 수자원의 효율적관리를 위해 하구언 방조제는 이미 건설되었고 앞으로 대규모의 항만개발과 대불산업단지조성을 위해 추가 3개의 만입해안해역에 댐으로 해역을 막아 매립공사를 추진하고 있다 그러나 이 지역에 대한 분석은 타당성의 여부만을 강조한 상업적 용역이 이루어지고 있고 장래 개발에 대해 학술적이고 실질적인 문제점 추출과 해결방아네 대해서는 무시하거나 경시한 바가 많다 더구나 태풍 저기압 등과 같은 자연재해를 고려한 분석은 시도되지 못하고 있다 따라서 개발전후의 현상에 대한 상세한 자료 및 현장 조사와 극한 상태를 고려하여 개발에 따른 수위상승 부진동, 조류 수질등 이해역의 변화요소를 수집하고 분석하며 과학적 접근방법에 기초를 둔 수치모델의 실험을 포함하여 현장관측 및 측정자료를 검증하는 것이 필수적이라고 사료되어 종합분석의 한단계로 여기서는 하구언 및 하구간척(Land Reclamatic of Estuary barren)으로 해역축소에 따른 해면변화의 실제현상을 조사하여 정리하고 이를 수치모델을 통해 시뮬레이션하여 보았다 이는 종합개발의 좋은 기초자료로 이용됨은 물론이로 이지역의 개발에 기여할 것으로본다.적절하게 가정된 지반의 응력-변형률 관계와 간극수압특성에 의하여 고려되었다. 그 결과 응력 및 변위가 심하게 발생하는 지역은 황색 점토층이었으며 이로부터 황색 점토층에서 부터 파괴면이 생성되어 다른 지역으로 전파되었음을 유추할 수 있었다.form trap with 2.88[eV] deep of injected space charge from the chathode in the crystaline regions. The origin of ${\alpha}$$_2$ peak was regarded as the detrapping process of ions trapped with 0.9[eV] deep originated from impurity-ion remained in the specimen during production process of the material, in the crystalline regions. The origin of ${\beta}$ peak was concluded to be due to the depolarization process of "C=0"dipole with the activation energy of 0.75[eV] in the amorphous regions. The origin of ${\gamma}$ peak was responsible to the process combined with the depolarization of "CH$_3$", chain segment, with the activation energy of ca

  • PDF

Vibration Reduction Effect and Structural Behavior Analysis for Column Member Reinforced with Vibration Non-transmissible Material (진동절연재로 보강된 기둥부재의 진동저감효과 및 구조적 거동분석)

  • Kim, Jin-Ho;Yi, Na-Hyun;Hur, Jin-Ho;Kim, Hee-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.94-103
    • /
    • 2016
  • For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted, and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.