• Title/Summary/Keyword: 벽 제트

Search Result 38, Processing Time 0.022 seconds

Total temperature investigation in free & wall jet regions (고속 자유/벽 제트 영역에서의 총온도 특성 고찰)

  • Jung Hyungab;Lee Jangwoo;Yu Mansun;Cho Hyunghee;Hwang Kiyoung;Bae Ju chan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.329-333
    • /
    • 2005
  • Total temperature distribution in high speed fee & wall jet regions was investigated using the total temperature probe. For the free jet, the distance of probe from the nozzle exit is changed in the range of 1, 2, 4 and 6 times o nozzle exit diameter. Energy separation phenomenon was observed on shear layer between jet and ambient. In wall jet region, impinging plate was fixed at Z/D=2 and total temperature distribution has been measured for various radial distance($R/D=1.25\sim2.0$). Energy separation phenomenon was found at wall jet boundary and near wall, and was compared with measured adiabatic wall temperature value.

  • PDF

Capability of Turbulence Modeling Schemes on Estimating the Film Cooling at Parallel Wall Jet-Nozzle Configuration (평행 벽 제트-노즐 형상에서 난류모델별 막냉각 예측 능력)

  • Lee, Jun;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • Numerical simulation has been performed in this study to investigate the capabilities of turbulence modeling schemes on estimating the film cooling at a referenced parallel wall jet-nozzle configuration. Also a additional simulation has been performed for film cooling under 2-dimensional axis symmetry conditions at a parallel wall jet-nozzle configuration. It was concluded that the best turbulence model is the standard $k-{\epsilon}$ model with enhanced wall functions. Also a additional simulation showed the film cooling characteristics that are resonable physically.

A Study on Flame Stabilization in the Axisymmetric Curved Wall Jet (축대칭 곡면벽 제트 유동장에서 화염 안정화에 관한 연구)

  • Gil, Yong-Seok;Cha, Min-Seok;Song, Yeong-Hun;Han, Jae-Won;Jeong, Seok-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.51-60
    • /
    • 1997
  • 축대칭 곡면벽 제트 버너를 제작하여 화염의 안정화 특성을 실험적으로 연구하였다. 축대칭 곡면벽 제트 유동은 난류 강도의 증가와 더불어 버너 선단 부근에 재순환 영역을 형성하여 화염의 안정화를 촉진시킴으로서 기존의 튜브 버너에 비하여 화염의 안정화 특성이 향상되었다. 시간적으로 화염의 위치가 변동하는 난류 화염에서 화염의 안정화 특성과 밀접한 관계가 있는 OH 라디칼과 온도를 PLIF와 CARS를 각각 적용하여 측정하였다. 고유속으로 연소시키는 경우에 버너 선단에 형성된 재순환 영역에 OH 라디칼이 상당량 분포하고 있었으며 통계적으로 고온을 유지하였다. 이는 버너 선단에 형성되는 재순환 영역에 고온의 기연 가스가 점화원 역할을 하여 화학 반응이 활발하게 일어나고 있음을 의미한다. 이러한 결과로부터 고속의 출구유속에서 화염 안정화 특성은 재순환 영역에 의하여 영향을 받고 있음을 확인하였다.

  • PDF

Measurement of Adiabatic Wall Temperature on an Impinging Surface by Under-expanded Jet (과소팽창된 충돌제트에 의한 단열벽면 온도 측정)

  • Yu, Man-Sun;Lee, Jang-Woo;Kim, Byung-Gi;Cho, Hyung-Hee;Hwang, Ki-Young;Bae, Ju-Chan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.79-84
    • /
    • 2005
  • An experimental investigation for impingement of under-expanded, axisymmetric jets on a flat plate has been conducted, and the surface pressure, the adiabatic wall temperature distributions on the plate have been measured in detail. For the explanation on the wall temperature distributions, the total temperature distributions along a free jet have also been measured with total temperature probes. In this study, the under-expansion ratio and the nozzle-to-plate distance have been considered as experimental parameters. Depending on nozzle-to-plate distances, different distributions of adiabatic wall temperature are shown by the energy separation at a jet edge and a impinged surface. Also, the recovery factor on a stagnation point decreases significantly due to the isolation of fluid particles in a central region.

An Availability Assessment of Protection Wall Installed in LPG Filling Station (LPG 충전소 내 설치된 방호벽의 효용성 평가)

  • Lee, Jin-Han;Jo, Young-Do;Moon, Jong-Sam;Kim, Lae Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.38-45
    • /
    • 2018
  • Jet fire, pool fire, and vapor cloud explosion are major accident scenarios in LPG filling station. The protection wall would mitigate radiation effect in a jet fire. In case of a pool fire, the protection wall would restrict expanding the pool area. The protection wall might both obstruct the dispersion of released vapor and protect blast overpressure in a vapor cloud explosion scenario. In this paper, An availability assessment method of the protection wall how much reduce damage to receptors is proposed. Additionally application cases are presented for the effectiveness of protection wall in the LPG filling station. The study shows that the protection wall can effectively reduce the death probabilities of receptors located behind the wall in cases of the jet fires and the vapor cloud explosions.

An Investigation of Roughness Effects on 2-Dimensional Wall Attaching Offset Jet Flow (조도가 2차원 벽부착 제트유동에 미치는 영향에 관한 연구)

  • 윤순현;김대성;박승철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.219-230
    • /
    • 1995
  • The flow characteristics of a two-dimensional offset jet issuing parallel to a rough wall is experimentally investigated by using a split film probe with the modified Stock's calibration method. The mean velocity and turbulent stresses profiles in the up and down-stream locations of the wall-attachment regions are measured and compared with those of the smooth wall attaching offset jet cases. It is found that the wall-attachment region on the rough wall is wider than on the smooth wall for the same offset height and the jet speed. The position of the maximum velocity point is farther away from the wall than that for the smooth wall case because of the thick wall boundary layer established by the surface roughness. It is concluded that the roughness of the wall accelerates the relaxation process to a redeveloped plane wall jet and produces a quite different turbulent diffusion behavior especially near the wall from comparing with the smooth plane wall jet turbulence.

Optimization study of pulsating jet for reducing the separation bubble behind the vertical fence (수직벽 후방박리영역 감소를 위한 맥동제트의 최적화 연구)

  • Choi, Young-Ho;Kang, In-Su;Kim, Hyoung-Bum
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.185-188
    • /
    • 2008
  • In this study, we experimentally investigated that the optimization of pulsating jet to reduce the separated flow region behind the vertical fence. The vertical fence was submerged in the turbulent boundary layer in the circulating water channel and we applied phase averaged PIV method to measure the instantaneous velocity fields around the fence. One cycle of pulsating jet is divided into 20 phases and grabbed total 200 instantaneous velocity fields at each phase. The experiments were performed by varying the frequency, maximum jet velocity and the shape of pulsating jet wave. Pulsating jet was precisely made by piston-type pump controlled by the computer. The obtained results were compared with normal fence flow. From this study, we found there is the specific frequency which is effective in reducing the reattachment region.

  • PDF

A Study on the Thickness Characteristics of the Liquid Sheet Formed by an Impinging Jet Onto a Wall (벽 충돌 제트로 생성되는 액막의 두께 분포 특성 연구)

  • J. S. Lee;T. Y. Lee;J. M. Jo;B. S. Kang
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.68-74
    • /
    • 2023
  • In this study, the thickness of the liquid sheet formed by a low speed impinging jet onto a wall was measured by the direct contact method. The spatial distribution characteristics of the sheet thickness in the radial and circumferential directions, and the effects of jet velocity and liquid viscosity were analyzed. The measurement results were compared with the theoretical predictions for two impinging jets. The wavy surface was observed for low viscosity water, but not for high viscosity glycerol solutions. The sheet thickness decreased as the circumferential angle or the distance from the impinging point increased. The sheet thickness increased as the liquid viscosity increased. Comparison with the theoretical predictions showed some differences from the measurement results.

A Study on the Characteristics of the Liquid Sheet Formed by a Splash Plate Nozzle at Low Jet Velocities (충돌벽 노즐의 저속 제트에 의한 액막 특성 연구)

  • H. U. Park;J. D. Kim;G. E. Song;B. S. Kang
    • Journal of ILASS-Korea
    • /
    • v.29 no.2
    • /
    • pp.75-82
    • /
    • 2024
  • In this study, the thickness of the liquid sheet formed by a splash plate nozzle at low jet velocities was measured by the direct contact method. The spatial distribution characteristics of the sheet thickness in the radial and circumferential directions, and the effects of jet velocity and liquid viscosity were analyzed. The wavy surface was observed for low viscosity water, but not for high viscosity glycerol solutions. The sheet thickness decreased as the circumferential angle or the distance from the impinging point increased. The sheet thickness increased as the liquid viscosity increased. Comparison with the theoretical predictions for two impinging jets showed some differences from the measurement results.

Heat Transfer on a Jet Vane Surface Installed in a Rocket Nozzle (로켓노즐에 장착된 제트베인 표면의 열전달 특성)

  • Yu Man Sun;Cho Hyung Hee;Hwang Ki Young;Bae Ju Chan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • Jet vane is an useful component which is installed at the end of a nozzle for the purpose of the posture control and the secure controlling stability during the initial launching of a rocket. During several seconds from its initial launching moment, the JV driving part is heated due to the direct contact of the vane with the combusted gas and the vane is ablated mechanically or chemically. In this study, as the fundamental study for the thermal analysis of jet vane, the heat transfer into a jet vane which is located in the uniform supersonic flow field is calculated. For this, boundary layer integral method and finite difference method are used simultaneously. Based on the thermal boundary conditions derived from the analysis, the transient heat conduction in the vane is also calculated.