• Title/Summary/Keyword: 베이스 트랩

Search Result 3, Processing Time 0.015 seconds

On the Minimization of Room Resonance by Room Tuning (룸 튜닝에 의한 실내 공진의 최소화)

  • Kang, Seong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.507-513
    • /
    • 2012
  • The room modes were showed as the peaks and dips on the low frequency response of the loudspeaker, and were one of the biggest obstacles to reproduce the sound. In order to reduce the occurrence of resonance, equalizing is performed at one position, and the frequency response to be equalized is valid only at that position. Performing the equalization would improve the flatness of the frequency response a little, but it cannot eliminate the ringing. Another method is that it is located the speaker at the specific position where the room resonances were not frequently happened. However, there may be the practical limitation that you may not be able to install the speaker at the position to be wanted. One of the practical solutions to decrease the production of resonance in room is the use of bass trap. In this paper, the practical limit for the room tuning using an equalizer and the room optimization will be discussed. The use of bass traps to solve the resonance problem that is always happened in the room is also proposed.

The reliability physics of SiGe hetero-junction bipolar transistors (실리콘-게르마늄 이종접합 바이폴라 트랜지스터의 신뢰성 현상)

  • 이승윤;박찬우;김상훈;이상흥;강진영;조경익
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.239-250
    • /
    • 2003
  • The reliability degradation phenomena in the SiGe hetero-junction bipolar transistor (HBT) are investigated in this review. In the case of the SiGe HBT the decrease of the current gain, the degradation of the AC characteristics, and the offset voltage are frequently observed, which are attributed to the emitter-base reverse bias voltage stress, the transient enhanced diffusion, and the deterioration of the base-collector junction due to the fluctuation in fabrication process, respectively. The reverse-bias stress on the emitter-base junction causes the recombination current to rise, increasing the base current and degrading the current gain, because hot carriers formed by the high electric field at the junction periphery generate charged traps at the silicon-oxide interface and within the oxide region. Because of the enhanced diffusion of the dopants in the intrinsic base induced by the extrinsic base implantation, the shorter distance between the emitter-base junction and the extrinsic base than a critical measure leads to the reduction of the cut-off frequency ($f_t$) of the device. If the energy of the extrinsic base implantation is insufficient, the turn-on voltage of the collector-base junction becomes low, in the result, the offset voltage appears on the current-voltage curve.

A Study on the Measurement Method for Improvement of Reliability for Heavy-Weight Floor Impact Sound Measurement (중량 바닥충격음 측정의 신뢰성 향상을 위한 측정방법 검토)

  • Joo, Moon-Ki;Park, Jong-Young;Yang, Kwan-Seop;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2008
  • Most of receiving rooms for the measurement of floor impact sound have rectangular shapes with couple of meters of dimension, with reflective finishing, no furniture, no curtains. Modal overlaps in those condition are the major reason for the low reproducibility, and as a matter of course, the low credibility. It is the major purpose of this study that searching for a better measurement method which mitigate the effect of modal overlap on measurement. Two ways of methods are tested. One is the way described in ISO standards which enables controlling the room modes of receiving rooms, the other is the way which enables to get more precise spatial averages in receiving rooms with room modes. It is not easy maintaining the reverberation time of low frequency bands in the range between 1s and 2s, though it is proven to be effective controlling the room modes with base traps. Space-time average SPL's through combinations of rotating microphones are easy to measure, and have good consistencies with average SPL of entire receiving room.