• Title/Summary/Keyword: 법랑질 두께

Search Result 101, Processing Time 0.025 seconds

Effect of $CO_2$ Laser on Caries Inhibition Evaluated by Laser Fluorescence Measurement (이산화탄소 레이저의 우식 억제 효과에 대한 레이저형광측정 평가)

  • Kim, Seong-Hyeong;Lee, Kwang-Hee;Kim, Dae-Eop;Lee, Ji-Young;Song, In-Kyung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.153-160
    • /
    • 2003
  • The purpose of study was to evaluate the effects of the $CO_2$ laser irradiation on demineralization inhibition and rehardening of human primary tooth enamel by laser fluoresecence measurement. Enamel specimens were made from the human primary teeth. The center spots of the specimens about 2 mm diameter were irradiated by $CO_2$ laser at the conditions of focused continuous or defocused pulsed, 3 or 6 W, for 4 seconds, before or after the demineralization by Coca-Cola for 24 hours at $37^{\circ}C$. The Diagnodent was used to measure the degree of demineralization and rehardening. There was no significant difference between focused continuous and defocused pulsed irradiation. 6W irradiation inhibited the demineralization but 3W did not. 6W irradiation rehardened the demineralized enamel but 3W did partially. The color of enamel was changed to brown to black after 6W irradiation but 3W caused no color change. $CO_2$ laser irradiation showed the effects on demineralization inhibition and rehardening of human priamary tooth enamel, and the laser fluoresecence measurement technique seemed to be a valid evaluation method.

  • PDF

INFLUENCE OF THE ENAMEL TREATMENT WITH ER:YAG LASER ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANT (Er:YAG 레이저를 이용한 법랑질 표면처리가 치면열구전색제의 미세누출에 미치는 영향)

  • Lee, Ji-Hyun;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.192-200
    • /
    • 2006
  • The aim of this study was to assess the microleakage underneath a pit and fissure sealant bonded to occlusal surfaces treated by Er:YAG laser To determine the most effective energy density of laser, fourteen specimens were irradiated from 50mJ to 300mJ at 3Hz. After irradiation, the lased specimens were observed under the scanning electron microscope. Thirty six non-carious extracted premolars were randomly assigned to four groups of nine teeth: group 1, no treatment on the occlusal surface; group 2, acid etching for 15 seconds; group 3, Er:YAG laser irradiation; group 4, acid etching followed by Er:YAG laser irradiation. The pits and fissures were sealed with unfilled sealant(Helioseal F) and the specimen teeth were thermo-cycled, immersed in 2% Rhodamine B solution, longitudinally sectioned and analyzed for microleakage with fluorescent microscope. The results were as follows: 1. Er:YAG lased surfaces with 50mJ, 3Hz showed a similar pattern of irregularity with acid etched enamel surfaces 2. The mean microleakage score increased in the order of group 2, 4, 3 and 1. There was no significant difference among group 1, 3 and 4(p>0.05), however group 2 showed significantly less microleakage compared with group 1 and 3. Conclusively, the laser irradiation seemed not enough to replace the acid etching for proper retention of pit and fissure sealants.

  • PDF

Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography (디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가)

  • An, Seo-Young;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2013
  • This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five disc-shaped specimens ($5mm{\times}1mm$) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink, Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.

Intrapulpal Temperature Change during Cavity Preparation on the Enamel and Dentin with an Er:YAG Laser (Er:YAG 레이저를 이용한 법랑질 및 상아질 와동 형성시의 치수내 온도변화)

  • Yang, Hee-Young;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.4
    • /
    • pp.457-464
    • /
    • 2005
  • The purpose of our study was to investigate whether the intrapulpal temperature during cavity preparation of enamel or dentin with Er:YAG laser still remained in range of safety for dental pulp protection when combined with appropriate water flow rate. The effect of different pulse repetition rates at the same pulse energy during ablation was evaluated as well. Caries-free, restoration-free extracted human molar teeth were prepared for the specimen and divided two experimental groups of enamel and dentin. Each group comprised 5 specimens and each of tooth specimens were embedded into a resin block each and measuring probe was placed on the irradiated pulpal walls. For experiments of dentin ablation, enamel layers were prepared to produce dentin specimen with a same dentin thickness of 2 mm. A pulse energy of Er:YAG laser was set to 300 mJ and three different pulse repetition rates of 20 Hz, 15 Hz and 10 Hz were employed. Laser beam was delivered with 3 seconds and less per application over enamel and dentin surfaces constant sized by $3\;mm{\times}2\;mm$ and water spray added during irradiation was a rate of 1.6 ml/min. Temperature change induced by Er:YAG laser irradiation was monitored and recorded While enamel was ablated, there was no significant difference of temperature related to pulse repetition rates(p=0.358) and temperature change at any pulse repetition rate was negligible. Significant statistical difference in temperature changes during cavity preparation in dentin existed among three different pulse groups(p=0.001). While temperature rise was noticeable when the dentinal wall was perforated, actual change of temperature due to Er:YAG laser irradiation was not enough to compromise safety of dental pulp when irradiation was conjugated with appropriate water spray. Conclusively, it can be said that cavity preparation on enamel or dentin with an Er:YAG laser is performed safely without pulp damage if appropriate volume of water is sprayed properly over the irradiated site.

In Vitro Evaluation of Microleakage and Penetration of Hydrophilic Sealants Applied on Dry and Moist Enamel (법랑질 수분 처리에 따른 친수성 치면열구전색제의 미세누출과 열구 침투도 평가)

  • Ku, Jaewon;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.272-279
    • /
    • 2017
  • This study aimed to evaluate the microleakage and penetration of two hydrophilic sealants, Embrace $Wetbond^{TM}$ and Ultraseal $XT^{(R)}$ $hydro^{TM}$, when applied on dry and moist enamel, as compared to a conventionally used hydrophobic sealant, $Clinpro^{TM}$. A total of 60 sound human third molars were randomly divided into 5 groups according to the enamel moisture control and the sealant material used. After sealant application, the teeth were thermocycled and immersed in 1% methylene blue dye. Subsequently, the teeth were sectioned twice and the sections were examined using an optical microscope and image analysis software. Application of Embrace $Wetbond^{TM}$ on either dry or moist enamel resulted in more microleakage than $Clinpro^{TM}$. Application of Ultraseal $XT^{(R)}$ $hydro^{TM}$ on dry enamel showed a similar level of microleakage to $Clinpro^{TM}$, but application on moist enamel resulted in more microleakage. There were no significant differences between the groups in penetration. In conclusion, application of hydrophilic sealants on moist enamel did not improve the sealing ability and showed lower sealing ability than that of $Clinpro^{TM}$ applied on dry enamel.

The Nanoleakage Patterns of Different Dentin Adhesive Systems (상아질 접착제의 nanoleakage 양상에 관한 연구)

  • Lee, Tae-Yeon;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.169-177
    • /
    • 2003
  • 본 연구는 total etching (Scotchbond Multi-Purpose; MP) 및 self-etching (Clearfil SE Bond; SE 과 Prompt L-pop LP) 상아질 접착제의 nanoleakage 양상을 관찰하고 열순환 후의 nanoleakage 양상의 변화를 분석하고자 하였다. 30개의 발거된 치아의 교합면 및 협, 설측 법랑질을 제거하였다. 열 순환 시행 여부에 따라 두 군으로 나누어 실험하였으며 각각의 상아질 접착제 도포 후 Z-250으로 교합면을 수복하였다. Silver nitrate용액 및 현상액에 침적 후치아의 협설 방향으로 평행하게 절단하여 SEM으로 관찰하였다. 서로 다른 양상의 nanoleakage가 관찰되었다. MP의 경우는 resin tag 주위로 뚜렷한 은의 침착을 관찰 할 수 있었으며 혼합층 전체 두께에 띠 및 점상으로 흩어져 침착된 은을 관찰 할 수 있었다. SE의 경우는 혼합층의 하층을 따라 은으로 침착된 선을 관찰 할 수 있었으며 혼합층과 adhesive 경계를 따라 무정형의 은 침착물 들을 관찰할 수 있었다. LP의 경우는 혼합층의 하부 및 혼합층 내에 띠 모양으로 은의 침착을 관찰 할 수 있었으며 혼합층의 하부에서는 관찰되지 않고 혼합층의 내부에서만 관찰되는 경우도 있었다. 열순환을 시행한 군에서는 전반적 nanoleakage 양상은 열 순환을 시행하지 않은 군과 유사하였으나 은 침착의 증가를 관찰 할 수 있었다.

RADIOPACITY OF CAD/CAM CERAMICS (CAD/CAM용 도재의 방사선 불투과성에 관한 연구)

  • Lee, Jong-Hyeok;Choi, Han-Seuk;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.357-365
    • /
    • 1998
  • 목적: 치과용 수복재료의 방사선 불투과성은 매우 다양하다. 따라서 다양한 수복재료의 방사선 불투과성을 인지하여 치질과 비교하면 이차우식의 진단에 도움이 될 수 있다. 도재의 방사선 불투과성에 따라 적절한 luting cement의 선택이 가농해진다. 수복재료의 방사선 불투과성은 알루미늄 step wedge 의 후경과 방사선 불투과성과의 상관관계 의해 측정된다. 본 연구의 목적은 CAD/CAM용 도재와 이틀의 접착에 쓰이는 접착재료의 방사선 불투과성을 조사해 적절한 재료의 선택과 이차우식 진단의 효율결정에 도움이 되게 하는데 있다. 방법: 본 실험에서는 CAD/CAM용 도재인 Vita MarkII, Dicor MGC와 이의 접착에 사용되는 Z-100, 그리고 luting cement인 Duo cement, Scotchbond resin cement를 사용해 방사선 불투과성을 측정하였다. 시편 제작을 위해 도재를 저속절단기로 두께 2mm, 3mm로 절단하였으며 Z-100과 cement시편은 두께 2mm와 3mm, 직경 7.0mm의 금속 주형을 제작한 후 재료를 양쪽 면에 유리판을 대고 조임쇠로 압접하였으며 광조사기를 사용하여 각 재료마다 두 가지 두께로 10개씩 100개의 시편을 제작하였다. 치질의 시편을 얻기 위해 교정 목적으로 최근에 발거된 정상적인 상악 소구치를 저속 절단기를 사용하여 협설측 교두정을 기준 삼아 2mm, 3mm 두께로 절단하였으며 방사선 불투과성의 기준을 위해 12개의 step으로 구성된 12mm두께의 aluminum step wedge를 사용하였다. Kodak E-Speed occlusal film에 aluminum step wedge와 시편들을 위치시킨 후 70kVp, 7mA, 2.16mm aluminum filtration으로 고정된 dental X-ray unit을 사용하여 target과 film 사이의 거리는 25cm, 노출시간은 0.2초로 하여 방사선 촬영을 한 다음, 현상된 방사선 사진상에 나타난 방사선 불투과성을 X-rite 301 densitometer를 이용하여 측정한 값들의 평균을 냈다. 얻어진 결과는 one-way ANOVA Duncan test(P<0.01)로 검증하였다. 결론: 1. Dicor MGC의 방사선 불투과성은 법랑질보다 약간 높게 나타났다.(P<0.01) 2. Vita Mark Il는 상아질보다 낮은 방사선 불투과성을 보였다.(P<0.01) 3. Z-100과 Luting cement들의 방사선 불투과성은 법랑질보다 높았다. Duo cement가 방사선 불투과성이 가장 높았고 그 다음이 Z-100, 그리고 Scotchbond resin cement 순이었다. 4. Z-100과 2종류의 방사선 불투과성 luting cement들은 Vita Mark II 와 같이 사용하면 2차우식 진단에 도움이 된다.

  • PDF

DEVELOPMENT OF DIGITAL IMAGING FIBER-OPTIC TRANS-ILLUMINATION SYSTEM (Digital Imaging Fiber-Optic Trans-Illumination System 개발)

  • Lee, Sang-Min;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.199-208
    • /
    • 2009
  • This study was performed to improve the conventional $DIFOTI^{TM}$ system(EOS Inc., USA) by developing the prototype of DIFOTI system which consists of light emitting diode(LED) and digital camera. The images of enamel surfaces treated under Carbopol 907 de-mineralizing solution were taken daily during 7 days of experimental periods by both DIFOTI systems. The results of comparative analyses of obtained images can be summarized as follows: 1. Trans-illumination indices of images taken from sample enamel surfaces were decreased with time in both systems. 2. The difference of intensity of luminance between sound and de-mineralized enamel surface in prototype DIFOTI system was shown to be relatively smaller than conventional $DIFOTI^{TM}$ system. The application of LED light source in prototype DIFOTI system could possibly reduce the amount of current consumption and that could ultimately lead us to the successful development of wireless model with battery. The innovative development of digital camera is undoubtedly expected to create much clearer image despite of wireless transfer. LED and digital camera can be combined into a smaller size but a very important task of improving image manager and analyzing program into a simpler and easier one to manipulate has to be solved.

  • PDF

A STUDY ON THE OPTIMAL ILLUMINATION POWER OF DIFOTI (DIFOTI 영상 최적화를 위한 광량에 대한 연구)

  • Kim, Jong-Bin;Kim, Jong-Soo;Yoo, Seung-Hoon;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.13-23
    • /
    • 2010
  • This study was performed to compare the quality of image processing between the newly developed prototype using light emitting diode(LED) and the conventional $DIFOTI^{TM}$ system(EOS Inc., USA). To estimate the optimal light emitting power for the improved images, primary enamel surfaces treated under Carbopol 907 de-mineralizing solution were taken daily during 20 days of experimental periods by both DIFOTI systems. The results of comparative analyses on the images obtained from both systems with polarized image as gold standard can be summarized as follows: 1. Trans-illumination indices of images taken from primary enamel surfaces were decreased with time in both systems. 2. The differences of intensity of luminance between sound and de-mineralized enamel surface in prototype DIFOTI system was shown to be relatively smaller than conventional $DIFOTI^{TM}$ system. 3. From the comparative analysis of images from both DIFOTI system with polarized images as gold standard, the difference between sound and de-mineralized enamel surface of intensity of luminance of $DIFOTI^{TM}$ system was more correlated to polarized images than prototype of DIFOTI system. With the optimal LED emitting power, the control of aperture of digital camera is considered as the another key factor to improve the DIFOTI images. For the best image quality and analysis, the development of the improved image processing software is required.