• 제목/요약/키워드: 밸브제어

검색결과 896건 처리시간 0.023초

제어밸브의 유량특성에 따른 에어스프링의 성능 변화 (Effect of Control Valve Flow Rates Characteristics on the Performance of an Air Spring)

  • 한승훈;장지성;지상원
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권3호
    • /
    • pp.8-14
    • /
    • 2016
  • This study describes the effect of the critical pressure ratio of a control valve on the performance of an air spring system composed of an air spring, auxiliary chamber, control valve and mass in order to suggest a more efficient design for an air spring system. The critical pressure ratio of the control valve is assumed to have a fixed value, but the critical pressure ratio of the control valve is known to have various values between 0.05 and 0.6, and the effect of the variation of the critical pressure ratio on the performance of the air spring system has not yet been reported. The analysis derives nonlinear and linear governing equations of the air spring system, including the critical pressure ratio of the control valve. This simulation study is presented to show that the impedance and transmissibility characteristics of the air spring system change due to variations in the critical pressure ratio of the control valve as well as its sonic conductance. As a result, the critical pressure ratio of the control valve should be maintained as large as possible to improve the vibration isolation characteristics of the air spring system.

내해수용 Actuator system의 내식성에 미치는 Cr+6 free 화성피막 용액적용 효과 (The effect on corrosion resistance of actuator system plated with Cr+6 free chemical conversion solution for ocean plant.)

  • 박정환;김태원;조대형;김정수;한수민;정대희;전규성
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.105-105
    • /
    • 2017
  • actuator system은 조선, 제철, 석유화학 및 중공업 등 다양한 분야에서 각종 유량 및 공기압 등을 제어하는 밸브에 필수적으로 사용되는 핵심 부픔이다. 최근 유정 개발 등 해양구조물 설치 조절이 복잡화 되면서 본 부품이 해양산업에 사용되는 빈도가 증가하고 있다. 이 경우 본 부품이 염분이 많은 바닷물 또는 주변 환경에 직접 노출되기 때문에 내식성이 매우 엄격하게 관리되고 있다. 본 부품에 부식이 발생할 경우 control system의 작동을 지배하는 구성 품에 부식이 발생하여 actuator로서 기능을 상실하여 오동작이나 설비 가동이 중단되는 사례가 빈번하다. 현재 본 부품의 내식성 향상을 위해서는 금속기 표면에 페인트를 사용하는 방법이 가장 널리 사용되고 있는 방법이다. 이 경우 금속 표면과 도장 면과의 사이에 기포발생이나 이물질 유입 등으로 인한 밀착성이 감소되거나 blister 등으로 인하여 도장 코팅 면이 박리되는 사례가 빈번하다. 이를 방지하기 위해서 최근 고 밀착성 내식용 도장 방법을 적용하고 있으나, 이 방법으로 도장한 부품의 표면에 충격 등으로 인한 결함이 발생할 경우 pitting corrosion 등 급격한 부식이 발생하여 이에 대한 근본족인 대책 수립이 절실한 실정이다. 본 연구에서는 근본적으로 금속기 표면과 밀착성이 우수한 화성피막 용액을 이용하여 희생양극에 의한 내식성을 확보하고, 다양한 용도에 적합한 색상 도료를 화성피말 위에 적용하여 화성피막 층의 보호 및 actuator의 목적에 맞는 도장을 하였다. 희생 양극효과를 극대화 할 수 있는 최적 화성피막 층은 $15{\mu}m$이며 이때 1,000시간 이상의 내식성을 확보하였다. 이 경우 이론적인 내식 수명은 2년으로 추정할 수 있었다.

  • PDF

초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계 (Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler)

  • 김연환;배용채;김재원;이두영;허해용
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

방향제어 조직밸브의 동특성에 관한 연구 (A Study on Dynamic Characteristics of Directional Control Logic Valve)

  • 이일영;오세경
    • 수산해양기술연구
    • /
    • 제24권4호
    • /
    • pp.172-179
    • /
    • 1988
  • A cartridge type hydraulic logic valve consists of simple two port valve whose poppet is closed or opened by means of pressure signal of a pilot line. Accordingly, the logic valve can be used not only for direction, flow and pressure control purpose but also for versatile function valve which enables all above mentioned functions. In addition, the valve has little internal leakage and pressure loss, superior response characteristics and easiness in making small block type valve. The above mentioned good performances being recognized recently, the logic valve has been used widely in the large scale hydraulic system such as a hydraulic press system, for the performance requirements of high speed operation and precise control characteristics. However, there are scarce reports until now, except for a few ones from Aachen Institute of Technology in West Germany, so it is necessary to be studied on development and investigation for practical application. This paper showed that the static and dynamic characteristics of a logic valve when the logic valve is used for directional control, to investigate the relations between the valve operating characteristics and the valve design conditions. From the above mentioned procedure, it was ascertained that the valve operation characteristics obtained by numerical analysis showed good agreements with experimental results. The representative results obtained are as follows; 1. During the valve is closing, the poppet velocity is almost constant in the logic valve. 2. The pilot pressure P sub(3) and the resistance R in the pilot line have much influences on the valve operation time. 3. Spring strength have not such a severe influence on the valve operating time. 4. The operation characteristics of the logic valve can be estimated with good accuracy comparatively by numerical analysis with the equations describing poppet motion.

  • PDF

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로- (Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.57-66
    • /
    • 2018
  • 29명이 사망하고 40명이 부상을 입은 제천 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 원인을 초기대응과 관리적인 측면을 중심으로 분석하였다. 초기대응 측면은 119신고 지연, 2층 세신사 비상구로 피난유도를 하지 않음, 1층과 3층 비상계단쪽 방화문 개방 상태 유지, 3층 주계단실 쪽 방화문 닫지 않음, 비상방송을 하지 않음으로 분석하였다. 관리적인 측면은 1층의 스프링클러설비 알람밸브 폐쇄, 소방펌프 제어반에서 기동 정지 위치에 놓음, 주차장 반자 안 누수 및 누전 방치, 2층 여탕의 휴게실 피난구유도등이 가려져 있고 비상구에 물건이 적치됨, 2층 자동문의 조작버튼 불량상태로 방치, 형식적인 소방안전관리, 소방시설 부실한 자체점검, 방화셔터와 배연창 미작동으로 분석하였다.

액체로켓 LOX 공급계의 저압 배관시스템 개발 (Development of the Low Pressure Piping System for the Liquid Rocket LOX Feed System)

  • 전상인;정진택;김우겸;박준성;권오성;김영목
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.322-325
    • /
    • 2007
  • 본 논문은 터보펌프를 사용하는 액체로켓의 저압 LOX 공급계의 개발 프로세스를 제공한다. 대한항공은 한국항공우주연구원과 협력하여 터보펌프 공급을 위한 LOX 공급계 개발을 수행하였다. LOX 공급계는 극저온의 온도와 무게절감을 위한 얇은 배관두께가 특징이다. 본 프로젝트의 시스템은 주 배관과 LOX 온도 제어를 위한 재순환 배관으로 구성되어 있다. 각 배관시스템은 벨로우즈, 필터, 오리피스, 밸브류, 플랜지와 서포트로 구성되어 있다. 이 논문에서는 시스템 설계 및 제작, 구조 및 열 해석, 단품 시험에 대하여 설명하였다. 최종적으로, 이 시스템은 한국항공우주연구원의 PTF 시험설비에 조립되어 요구 성능을 달성하였다.

  • PDF

초음속 이젝터의 압력회복에 관한 연구 (Pressure Recovery in a supersonic ejector of a high altitude testing chamber)

  • 조지;공창덕
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.833-837
    • /
    • 2010
  • 본 연구는 최소 압력 모사로 엔진 배기가스를 배출시키기 위한 최적 이젝터 크기를 결정하기 위한 것을 목적으로 한다. 실험 챔버로 유입되는 2차 냉각 공기는 유량제어 밸브들과 진공펌프가 장착된 배출구를 통해 엔진배기가스는 분리되어 배출된다. 기존 고도시험 장치와 달리, 본 연구에 제안한 형상은 기존 이젝터의 압력 회복을 개선한 좀 더 작은 포획 면적을 가진 배기 이젝트를 사용하면 가스에 스텔링 챔버로 부터 20% 냉각 공기를 부가하여 배출시키도록 크기가 정해진다. 제안된 형상은 벨마우스 이젝터와 엔진배기 출구의 면적비가 이론적으로 약 1.2를 갖는다. 제안된 형상의 혼합 공기 모사결과에 따르면 큰 에너지는 기존 시스템 비해 좀 더 개선된 압력 회복과 감소된 전력 소모를 같음을 확인하였다.

  • PDF

완전급수상실사고/복구과정의 평가와 관련비상운전절차의 검토 (Evaluation of Total Loss of Feedwater Accident/Recovery Phase and Investigation of the Associated EOP)

  • Bang, Young-Seok;Seul, Kwang-Won;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.37-50
    • /
    • 1993
  • 완전급수상실사고 및 복구가정의 사고전개와 열수력학적 거동을 평가하기 위해 RELAP5/MOD3 계산을 수행하고 LOFT L9-l/L3-3 실험 결과와 비교하였다. 또한 본 사고의 주요 열수력 현상에 대한 코드의 예측도를 평가하였다. 본 연구의 결과로서 가압기 수위가 만수위에 도달할 때까지 살수를 이용한 압력 제어, 가압기 압력방출 밸브를 통한 가압방지, 증기발생기 재충수에 의한 이차측 열제거 능력의 재확보, 지속적인 자연순환에 의한 효과적인 일차계통의 냉각등이 이루어 질 수 있고 이 과정중 노심노출은 나타나지 않음이 밝혀졌다. 또한 현재의 현상-중심 비상운전절차서 특히 과압방지성능 및 증기발생기 회복절차 등의 유효성을 입증하기 위해서는 발전소 고유한 평가가 필요함이 밝혀졌다.

  • PDF

쿼드콥터형 드론에 설치된 가스총 결합유닛의 개발 (Development of the Connection Unit with a Gas Gun Installed in a Quadcopter-type Drone)

  • 전준하;강기준;권현진;장세명;정재복;백재구
    • 한국항공우주학회지
    • /
    • 제46권9호
    • /
    • pp.774-781
    • /
    • 2018
  • 본 연구에서는 쿼드콥터형 소형 무인 드론에 이산화탄소를 작동 기체로 하는 가스총을 설치하여 가축 방역에 응용할 수 있는 발사체 및 결합 유닛을 개발하였다. 시스템은 상용 드론과 가스총, 솔레노이드 밸브, 무선 통신 제어기 등으로 구성된다. 발사된 탄환의 속도를 측정하고, 지상 시험, 실제 비행체에의 탑재 시험 등을 거쳐 최종 검증하였다. 본 연구 개발을 통하여 농업, 소방 등의 다양한 방역 및 방재 분야에 발사체 기술을 적용할 수 있는 가능성을 확인하였다.

핫가스 바이패스 밸브를 이용한 R744용 초임계 냉동사이클의 부하제어에 대한 성능 분석 (Performance analysis for load control of R744(carbon dioxide) transcritical refrigeration system using hot gas by-pass valve)

  • 노건상;손창효
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2189-2194
    • /
    • 2009
  • 부분 부하운전시 냉동공조장치의 능력을 조절하기 위해서 핫가스 바이패스 기술을 적용한다. 이 개념은 압축기에서 나온 고온의 냉매증기를 증발기 입구측으로 보내는 것이다. 본 논문에서 질량과 에너지 보존법칙을 근거로 CO2에 대한 핫가스 바이패스 개념을 적용하여 분석한다. 본 논문에서 고려된 운전 변수는 냉동장치의 압축효율, 과열도, 가스냉각기 냉매 출구온도, 증발온도 등이다. 주요결과를 요약하면 다음과 같다. 과열도, 가스냉각기 출구온도, 증발온도는 냉동장치의 COP와 냉동능력에 영향을 미치는 것을 알 수 있다. 따라서 이러한 결과의 면밀한 분석을 통해 R744용 냉동장치를 설계할 필요가 있다.