• Title/Summary/Keyword: 백-밸브 마스크

Search Result 9, Processing Time 0.017 seconds

Comparative Analysis of Tidal Volume and Airway Pressure with a Bag-valve Mask using RespiTrainer (RespiTrainer를 활용한 백-밸브마스크 환기에서 일회호흡량과 기도압 비교 연구)

  • Shin, So-Yeon;Lee, Jae-Gook;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.76-81
    • /
    • 2014
  • The purpose of this study was to comparative analysis of tidal volume and airway pressure after one-rescuer BVM, two-rescuer BVM, advanced airway devices with a Bag-valve mask using RespiTrainer. The data were obtained from June 2 to 10 in 2014. The collected data were analyzed using the SPSS WIN 18.0 program. The results showed that BVM ventilation using the endotracheal intubation produced higher mean tidal volume $497{\pm}78mL$, Two-rescuer ventilation $479{\pm}91mL$ One-rescuer ventilation $386{\pm}59mL$, King LTS-D $365{\pm}05mL$, Laryngeal mask airway (LMA) $351{\pm}35mL$. Peak airway pressure was higher in BVM ventilation using the endotracheal intubation. As a result, the study confirmed that the BVM Ventilation by endotracheal intubation and Two-rescuer BVM ventilation to one third the bag depth squeeze method is appropriate.

The Effect of Bag-Valve Mask Using Skill Education with Flowmeter

  • An, Juyeong;Kim, Hwan-Hui;Yun, Hyeong-Wan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.219-229
    • /
    • 2022
  • This study is to evaluate the intervention effect using a flowmeter in bag-valve mask skill education. The purpose of this study was to compare the accuracy of bag-valve mask skill between intervention group with flowmeter and control group without flowmeter, understand the improvement effect of skill education of bag-valve mask, and provide basic data to suggest the method of skill education. The total number of subjects of this study was 60, with 30 intervention group and 30 control group. In comparison of the optimal number of normal tidal volume range at pre-test and post-test, the normal range percentages of the intervention group before and after education were 32.8% and 86.7%, respectively, and there was a significant difference(p<0.01). The normal range percentages of the control group before and after education were 20.0% and 34.7%, respectively, and there was a significant difference(p<0.05). To evaluate the factors associated with good performance of bag-valve mask skill of the subjects including the normal range of tidal volume, the logistic regression analysis has been performed, and the significant influential factors were gender(10.305, 1.20-87.98), educational experience of field practice(31.674, 1.25-805.16), and intervention(92.750, 4.58-1879.69). Through this study, it was confirmed that the intervention using flowmeter for the skill education of bag-valve mask was effective, and it is necessary to consider reflecting it in the education of students majoring in emergency medical technology in the future.

Comparison of ventilation effects by mask-sealing methods during bag-valve-mask ventilation (백-밸브-마스크 환기 시 마스크 밀착방법에 따른 환기효과 비교)

  • Lee, Nam-Jong;Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.73-82
    • /
    • 2018
  • Purpose: The purpose of this study was to compare the tidal volumes and airway pressures of 3 mask-sealing methods (one hand C-E, two hands C-E, and one hand O-E) for ventilation treatment. Methods: The study subjects were 45 paramedic students. Tidal volume was measured for the three sealing methods by setting a ventilator, connecting it to the masks for 2 minutes, and using Respi-trainer software. Results: Regarding general characteristics, the group of men, in upper grades, and with practical training experience and experience and experience in the implementation of bag-valve-mask ventilation provided higher tidal volumes. Regarding physical characteristics, larger hands and greater grip strength correlated with higher tidal volume. Two hands C-E generated the highest tidal volume of $483.78{\pm}34.14mL$, one hand O-E generated $449.59{\pm}51.09mL$ and one hand C-E generated $394.31{\pm}68.95mL$. Conclusion: Means of tidal volumes were statistically significantly different based on mask sealing methods (p<.001). Two hand C-E was performed by the two-persons task and was suggested as the most effective method. For the one-person task, one hand O-E was the more effective method compared to the previous one hand C-E.

The Effects of Training on the Proper Use of Respiratory Rate Measurement Devices for Providing High-Quality Artificial Ventilation

  • Jae-Ran Lim;Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Ho-Jin Park
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.165-171
    • /
    • 2024
  • This study aims to investigate the appropriate volume of artificial ventilation and success rate when Basic - emergency medical Technician administer bag valve mask(BVM) artificial ventilation to patients experiencing respiratory failure or respiratory arrest using a respiratory rate measurement device. The research was conducted from December 11th to 12th, 2023, targeting 20 Basic - emergency medical Technicians enrolled at D University. Ten participants were selected for the experimental group, receiving BVM ventilation training with the use of a respiratory rate measurement device, while the other ten were assigned to the control group, receiving BVM ventilation training without the use of a respiratory rate measurement device. The experiment involved providing artificial ventilation for 2 minutes. The results of the study indicated that the control group did not provide accurate tidal volume (p=.025). The experimental group demonstrated a higher success rate of ventilation over the 2-minute period, while the control group showed a significant difference (p=.001). Subjective perception of tidal volume and objectively measured tidal volume also exhibited a significant difference in the control group (p=.010). Therefore, training with a respiratory rate measurement device can align the subjective perception of tidal volume with objective measurements, increase the success rate of ventilation, and potentially contribute to improving survival rates in patients experiencing respiratory failure or respiratory arrest during cardiopulmonary resuscitation.

Comparison of cardiopulmonary resuscitation quality using the over-the-head and lateral conventional positions with a bag-valve-mask device performed by a single rescuer : A manikin study (백밸브마스크를 이용한 1인 심폐소생술에서 구조자 위치 변화에 따른 가슴압박과 인공호흡의 질 변화 연구)

  • Uhm, Tai-Hwan;Jung, Hyung-Keon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.1
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: There are few studies on the quality of cardiopulmonary resuscitation (CPR) performed by a single rescuer using a bag-valve-mask device. The aim of this study is to compare CPR quality outcomes according to the rescuer's position or mask fixation grip method and to determine the optimal means of achieving therapeutic goals. Methods: The three CPR methods were defined as over-the-head, lateral-superior, and lateral-inferior, depending on the rescuer's position or mask fixation hand placement. CPR quality was estimated for 83 paramedic students who performed 5 minutes of CPR in a randomized sequence on a manikin using each of the three methods. Results: The over-the-head method showed no advantage for cardiac compression and ventilation quality, but minimized the rescuer's fatigue score. Conclusion: In contrast to previous studies or prevailing beliefs, the lateral-superior position is optimal for achieving therapeutic goals with moderate or minimal rescuer fatigue.

Effects of educational intervention on single-rescuer respiratory-assistant therapy using a bag valve mask (백-밸브-마스크를 이용한 1인 호흡보조요법 교육의 효과)

  • Lee, Yong-Jae;Uhm, Dong-Choon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.3
    • /
    • pp.29-40
    • /
    • 2019
  • Purpose: This study was conducted to identify the effects of educational intervention on pre-test and post-test tidal volume, endotracheal peak pressure, and ventilation interval measurements during single-rescuer respiratory-assistant therapy by paramedic students. Methods: The present study, with a quasi-experimental design, included a pre-test and post-test nonequivalent control group. A total of 62 paramedic students (31, experimental group; 31, control group) participated in this study. The intervention lasted 80 minutes. Data were collected from each student before the intervention and two weeks after the intervention, between September 3 and 21, 2018. The collected data were analyzed using IBM SPSS Statistics for Windows, Version 25.0. Results: Tidal volume (p<.001) and endotracheal peak pressure (p=.002) measurements after the intervention were significantly different between the two groups. Analysis of covariance was used to control the variance (the pretest value of endotracheal peak pressure) in order to identify the effect of the intervention in the two groups. Endotracheal peak pressure was not significantly different between the two groups. Conclusion: Education and training of paramedic students in emergency medical services on single-rescuer respiratory-assistant therapy is necessary for the emergency care of patients with respiratory arrest.

Assistant device development and effects for promotion of bag-valve-mask ventilation (백-밸브-마스크 환기증진을 위한 보조기구 개발 및 효과)

  • Kwon, Chan-Yang;Lee, In-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.49-59
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an assistant device for the promotion of bag-valve-mask ventilation based on a non-equivalent control group pre-test and post-test design. Methods: The experimental tool was a mask assistance device developed by the researchers. Data were analyzed using SPSS 21.0 with the cardiopulmonary resuscitation (CPR) evaluation program from August 18 to 30, 2016. The research tools included general, hand-related, and ventilation-related characteristics. Results: Before and after using the mask assistance device, the tidal volume increased by 64 mL (p<.001) from 461.76 mL to 525.86 mL. The tidal volume for control was 477.86 mL, and there was a statistical difference (p<.05). The ventilation frequency in device users was 10 times per minute for a total of 20 ventilations with before 10.65 after 10 times, and that of the control group was before 10.36 times after 10 times; there was no difference in both groups(p>.05). The accuracy of the assistance device was $81.72{\pm}30.86%$, which was a very high value. However, the accuracy of ventilation in the control group with no assistance device was $18.97{\pm}32.44%$, which was a very low accuracy rate. Conclusion: This study's results suggested utilizing the newly-developed mask assistance device in CPR, and showed increases in tidal volume and accuracy of ventilation using the bag-valve-mask ventilation equipment. The general and hand-related characteristics did not have any effect, so the use of the device proved to increase the efficacy in all users.

A comparison of ventilation effects using bag-valve-mask assist device (백-밸브-마스크 보조장치를 이용한 환기효과 비교)

  • EunYoung, Seo;ByoungGil, Yoon;GaEun, Kim;YougSeok, Kim
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.3
    • /
    • pp.37-46
    • /
    • 2022
  • Purpose: TThe experiment was designed to compare the efficiency of ventilation between conventional BVM ventilation and a newly devised A-BVM ventilation method with Tidal volume, total ventilation rate, average Ventilation speed, and average Ventilation volume. Methods: 40 Paramedical students who agreed to participate in the study were analyzed. Values were measured using IMB PASS after 2 minutes of Brayden Pro manikin with BVM and A-BVM ventilation. The difference in general characteristics was assessed by t-test and ANOVA and the difference in ventilation methods was analyzed by IBM SPSS. Results: A significant difference was found between the two ventilation methods in terms of tidal volume (t=-11.203, p<.001), ventilation time (t=-3.834, p<.001), and optimum ventilation probability (t=10.770, p<.001). A-BVM ventilation method, rather than BVM ventilation method, showed a value close to the appropriate amount recommended by Korean Advanced Life Support (500~600mL) in tidal volume, and higher in optimum ventilation probability. Conclusion: We could identify the a better mode of ventilation. Further studies on the efficacy of existing BVM ventilation methods as compared to device augmented BVM ventilation methods should be carried out to ensure that adequate ventilation is available to patients in clinical practice.

Effect of a CPR Educational Face Shield on Pathogenic Bacteria Protection (심폐소생술 교육용 페이스 쉴드의 병원성 세균 차단 효과)

  • Kim, Eun-Mee;Shim, Gyu-Sik;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.137-141
    • /
    • 2016
  • Cross contamination between a patient and rescuer or CPR trainees can occur when performing mouth to mouth ventilation during cardiopulmonary resuscitation (CPR). On the other hand, there has been a lack of research on the filtration efficacy of face shields that are designed to protect people from cross-contamination. This study aims to secure the safety of rescuers from communicable diseases in pre-hospital emergency settings and CPR trainees by verifying the protective effects of face shields. The FA shield and CM Shield were used to verify the safety. The bacteria collected from filters used by CPR trainees were incubated. These incubated bacteria were smeared onto the new filters, and were then blown out through the filters using a Bag Valve Mask (BVM) and the pathogens at the front and the back of the filters were checked. While the FA shield was effective in preventing the transmission of pathogens, the CM shield did not prevent the transmission of pathogens. Therefore, some of face shields that received national certification are ineffective in preventing cross-contamination. Accordingly, it is necessary to verify the safety of other face shields used domestically.