• Title/Summary/Keyword: 백색 굴뚝연기

Search Result 1, Processing Time 0.018 seconds

Design of Turbidity Measurement of White Plume using Optical Method (광학기법을 이용한 백색 굴뚝연기 혼탁도 측정의 설계)

  • Son, Hyun-Keun;Ban, Chae-Hoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1195-1200
    • /
    • 2020
  • The DOM (: Digital Optical Method), which measures the turbidity of chimney smoke, is a method of calculating the turbidity by setting the area to be measured and the contrast area using a low-cost digital camera that can be easily obtained. However, it is difficult to measure clouds and white smoke in a cloudy sky. In this paper, we develop a background sky type model that can represent the background sky and classify the type by periodically photographing it with a digital camera to solve this problem. In addition, based on the model, we develop a filter to optimize white smoke image and prove its excellence through experiments.