• Title/Summary/Keyword: 배플 간격

Search Result 4, Processing Time 0.017 seconds

Effect of baffle parameters on heat transfer in shell-and-tube heat exchangers (원통다관형 열교환기에서 배플인자가 열전달에 미치는 영향)

  • Lee, Sang-Cheon;Jo, Yeong-U;Nam, Sang-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.185-194
    • /
    • 1997
  • An experimental study has been performed on the effect of baffle parameters on shell -side heat transfer in a conventional shell-and-tube heat exchanger. The baffle spacing distance and the number of baffle were varied to investigate the behavior of unequal baffle spacing correction factor which is appeared in the Bell Delaware method for prediction of the shell-side heat transfer coefficient. It was obvious that heat duties obtained from the experiment significantly deviated from those calculated by the conventional Bell-Delaware method. A new correlation of the unequal baffle spacing correction factor was developed. It was shown that the new correlation improves the accuracy of the Bell-Delaware method considerably. This result may induce the use of the Bell-Delaware method in developing a computer software for design of shell-and-tube heat exchangers.

A Study on the Hydraulic Characteristics of Culvert Fishway with Offset Baffles and Fish Passage Effect (옵셋배플형 암거식 어도의 수리특성 및 어류이동효과에 관한 연구)

  • Park, Seong-Yong;Choi, Ji-Woong;Yoon, Byung-Man;Kim, Seo-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.1
    • /
    • pp.75-85
    • /
    • 2008
  • The pale chub (Zacco platypus) is a dominant species that migrates locally and inhabits in rivers in Korea. The fish movement at confluences or hydraulic connections is very important especially for the life of small fish as pale chub. If main stream and off-channel habitats are connected with culverts, they would restrict the fish movement due to the high flow velocities and low depths. In foreign conturies, design flow conditions of fish friendly culvert, including flood flow capacity and fish-passage flow capacity, were assigned. Installation of culvert fishways is one way to improve the fish-passing capacity of culverts. On the contrary, in Korea, the design flow of culvert contains only the flood flow capacity. The effect of the fish passage with offset baffles was tested with the fixed velocity method in an experimental flume. As a result, An occasion velocity 1.2m/s, proportional success of pale chubs pass is maximum 20% improve than without baffle flume for energy dissipate. Offset baffle fishway(baffle height 5cm) provides that resting areas and/or a continuous channel of low velocity water in culverts. Especially, short baffle areas are domain where the pale chubs pass. And, FLOW-3D, a three dimentional numerical model, was used in order to evaluate detailed hydraulic characteristics and application possibility in a culvert fishway design.

An Experimental Study of Shell and Tube Heat Exchanger Performance with Baffle Spacing (배플수에 따른 원통다관형 열교환기 성능에 관한 실험 적 연구)

  • Lee, Yuk-Hyeong;Kim, Sun-Yeong;Park, Myeong-Gwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1748-1755
    • /
    • 2001
  • The shell and tube heat exchangers were introduced to apply to a big capacity condenser and a high pressure feed water heater for power plant in the beginning of 1990s. Design and manufacturing technology fur shell and tube heat exchangers have been developed until now. But it is very difficult to calculate the expected performance characteristics of the shell and tube heat exchanger, because there are many design parameters to be considered according to internal structure and the shell side heat transfer mechanism complicately related to the design parameters. Design parameters to be considered in the design stage of shell and tube heat exchanger are shell and tube side fluids, flow rate, inlet and outlet temperature, physical properties, type of heat exchanger, outer diameter, thickness, length of tube, tube arrangement, tube pitch, permissive pressure loss on both sides, type of baffle plate, baffle cutting ratio. The propose of study is an analysis TEMA(Tubular Exchanger Manufacturers Association) E shell and tube heat exchanger performance with changing a number of baffles(3, 5, 7, 9, 11) and tubes(16, 20) and determined optimal baffle spacing.

A Numerical Study on an Optimum Design of a Hybrid Collector Coupled with the Principle of Cyclone, Baffle and Bag-Filter (싸이클론과 배플 및 백필터 원리를 결합한 하이브리드형 집진기의 최적화 설계를 위한 수치해석)

  • Hong, Sung-Gil;Jung, Yu-Jin;Lim, Ki-Hyuk;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.983-989
    • /
    • 2013
  • The current research reviewed the design conditions that would maximize the efficiency of the hybrid collector that combines in one unit "cyclone-inertial impaction-bag filter". The computational analysis for the shape of cyclone entry predicts that a design that installs the guide vane at the entry of the tangential type cyclone brings a high-rpm and powerful vortex, very effective in promoting the deflection of coarse particles from the streamline at the cyclone. As the lower part of the cyclone is venturi-shaped, however, a strong flow downward of 4 to 5 m/sec persists through the lower part of the hopper, revealing the likely reentrainment of collected dust. And the removal of the venturi at the lower part of the cyclone would solve the problem of the reentrainment of collected dust. The acceleration of the flow velocity through the adjustment of the gap of the collision baffle would increase the effect of collision, but as the interference with the dust separation is expected, the original design should be kept for the baffle.