• Title/Summary/Keyword: 배열회수

Search Result 133, Processing Time 0.032 seconds

A Technique of the Combined Cycle Heat Rate Allocation for the On-Line Performance Monitoring System (복합화력 온라인 성능감시 구현을 위한 열소비율 분담 기법)

  • 주용진;김시문
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.173-180
    • /
    • 2004
  • A technique of the heat rate allocation was devised to monitor the performance of Combined Cycle Power Plant. This calculates the expected heat rate of current conditions and compares it with actual values. Loss allocation in heat rate is reconciled by calculating the magnitude of the deficiency contributed by major components, such as the gas turbine, heat recovery steam generator (HRSG), steam turbine and condenser. Expected power output is determined by a detailed model and correction curves of the plant.

Surface Ultrastructure of Heterophyes nocens (Trematoda: Heterophyidae) (Heterophues nocens (Trematoda: Heterophyidae)의 표피 미세구조)

  • 채종일;정혜림
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.2
    • /
    • pp.75-82
    • /
    • 1992
  • The surface ultrastructure of Heterephyes nocens (Trematoda: Heterophyidae) was studied by scanning electron microscopy(SEM), The adult worms were recovered from experimentally infected cats and from a naturally infected patient. They were leaf-like, ventrally concave, and ovoid or lyriform in shape. Ciliated knob-like sensory papillae (type I) were observed in single or grouped forms on and around the oral sucker, whereas non-ciliated round swellings (type II papillae) were seen on the lip of the ventral sucker, The tegumental spines around the oral sucker were 5∼9 pointed, whereas those between the two suckers were 12∼17 pointed. yentrolaterally, three groups of 5∼6 type I papillae were located between the oral and ventral suckers, with single ones alternating between them. The genital sucker was protruded or depressed, depending on the contraction state of the nukes, and the gonotyl spine number ranged 50∼60. The number of tip points of tegumental spines was decreased posteriorly; finally they became 1∼3 pointed. On the dorsal surface, 4 groups of 4∼5 type I papillae were symmetrically located on both lateral sides, and the shape and distribution of tegumental spines were similar to those of the ventral surface. Although the tegumental ultrastructure of H. nocens was generally similar to those of other heterophyids, the genital sucker morphology including the number of gonotyl spines and/or the distribution pattern of tegumental spines and sensory papillae were suggested to be the characteristic features of H. necens.

  • PDF

A Numerical Analysis of Flow Characteristics in a Heat Recovery Steam Generator with the Change of Inlet Flow Conditions (배열회수보일러(HRSG)의 입구유동 경계조건에 따른 유동특성 변화에 관한 연구)

  • Kim, Tae-Kwon;Lee, Boo-Yoon;Ha, Ji-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.53-57
    • /
    • 2011
  • The present study has been carried out to analyze the flow characteristics of a heat recovery steam generator with the change of inlet flow conditions by using numerical flow analysis. The inlet of HRSG corresponds the outlet of gas turbine exit and the flow after gas turbine has strong swirl flow and turbulence. The inlet flow condition of HRSG should be included the exit flow characteristics of gas turbine. The present numerical analysis adopted the flow analysis result of gas turbine exit flow as a inlet flow condition of HRSG analysis. The computational flow analysis result of gas turbine exit shows that the maximum axial velocity appears near circular duct wall and the maximum turbulent kinetic energy and dissipation rate exist relatively higher gradient region of axial velocity. The comparison of flow analysis will be executed with change of inlet turbulent flow condition. The first case is using the inlet turbulent properties from the result of computational analysis of gas turbine exit flow, and the second case is using the assumed turbulent intensity with the magnitude proportional to the velocity magnitude and length scale. The computational results of flow characteristics for two cases show great difference especially in the velocity field and turbulent properties. The main conclusion of the present study is that the flow inlet condition of HRSG should be included the turbulent properties for the accurate computational result of flow analysis.

A Bitmap Index for Chunk-Based MOLAP Cubes (청크 기반 MOLAP 큐브를 위한 비트맵 인덱스)

  • Lim, Yoon-Sun;Kim, Myung
    • Journal of KIISE:Databases
    • /
    • v.30 no.3
    • /
    • pp.225-236
    • /
    • 2003
  • MOLAP systems store data in a multidimensional away called a 'cube' and access them using way indexes. When a cube is placed into disk, it can be Partitioned into a set of chunks of the same side length. Such a cube storage scheme is called the chunk-based MOLAP cube storage scheme. It gives data clustering effect so that all the dimensions are guaranteed to get a fair chance in terms of the query processing speed. In order to achieve high space utilization, sparse chunks are further compressed. Due to data compression, the relative position of chunks cannot be obtained in constant time without using indexes. In this paper, we propose a bitmap index for chunk-based MOLAP cubes. The index can be constructed along with the corresponding cube generation. The relative position of chunks is retained in the index so that chunk retrieval can be done in constant time. We placed in an index block as many chunks as possible so that the number of index searches is minimized for OLAP operations such as range queries. We showed the proposed index is efficient by comparing it with multidimensional indexes such as UB-tree and grid file in terms of time and space.

A Study on Partial Load Performance of Absorption Type Heat Pump for Waste Heat Recovery of Closed Cooling Water (기기냉각수 폐열회수용 흡수식 히트펌프의 부분부하 성능에 관한 연구)

  • Park, Byungchul;Kim, Taehyeong;Kim, Kwangsu
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.47-54
    • /
    • 2019
  • As absorption type heat pump for waste heat recovery is installed in combined cycle power plant for Energy Service Company, performance test is implemented to confirm the operation data on partial load. The operation data changes according to the heat pump operation on partial load are as follows. Total heat output increases, because waste heat of closed cooling water and a portion of LP steam from HRSG is supplied. But electric power output of steam turbine is reduced, because LP steam to steam turbine is reduced. And heat output from HP district heater and LP district heater is reduced, because HP turbine exhaust steam to HP district heater and LP district heater is reduced. On partial load operation, turbine output reduction is higher than the base load operation. Therefore, on partial load, heat pump should be operated in consideration of the heat output increase and electric power output reduction.

Experimental life history of Echinostoma cinetorchis (이전고환극구흡충의 실험실 내 생활사)

  • 이순형;채종일
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.39-44
    • /
    • 1990
  • The life history of Echinostoma cinetorchis was completed in the laboratory using Hippeutis cantors as the first and second intermediate host. The incubation for maturation of eggs and hatching of miracidia took 24 days at 28℃. On the 66th day after miracidial challenge, 16 snails were crushed and examined for the presence of E. cinetorchis larvae. The metacercariae were detected in all of the snails, and from three of them were found the rediae and cercariae. The morphological characteristics of the larvae and the experimentally obtained adults were compatible with that of E. cinetorchis.

  • PDF

A Design of Mooring Line for the Buoy-Enabled Underwater Surveillance System (부이형 수중감시 시스템에서 계류라인의 구조 설계)

  • Byun, Yang-Hun;Choi, Bum-Kyu;Oh, Tae-Won
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.12
    • /
    • pp.41-47
    • /
    • 2018
  • The buoy-enabled underwater surveillance system is a device that is installed in a particular sea area and operated for a certain period of tine and moved to another sea area after recovery. In this paper, a mooring method which is applied for a buoy-enabled underwater surveillance system was selected to maintain installation and enure stable operation. Also, the structure of the mooring line was designed. Two-point mooring method was selected considering interference with the communication cable of array-assembly. The composite structure of buoy chain, nylon rope, and anchor chain is designed as the basic component of mooring line. For the verification of design, a numerical simulation and wave tank experiment were performed. Their results were confirmed similarity in test condition. Finally, the mooring lines were designed for the environment of the sea trial location. The mooring line produced by the final design confirmed the stability above the significant wave height considered in the design on the sea trial.

Ultrastructural Changes on the Cuticular Surface, Excretory and Digestive Organs of Anisakis simplex Larvae Chronologically Recovered from Experimental Cats (실험감염 고양이로부터 경시적으로 회수한 고래회충 유충의 표피, 배설기 및 소화기의 미세구조 변화)

  • Sohn, Woon-Mok
    • Applied Microscopy
    • /
    • v.29 no.2
    • /
    • pp.211-221
    • /
    • 1999
  • The ultrastructural changes of cuticular surface, excretory and digestive organs of Anisakis simplex larvae chronologically recovered from experimental cats were observed with a SEM and TEM. The larva recovered from an experimental cat at 3 days post-infection (PI) retained the cuticular surface with regular transverse striations and a longitudinal groove on the lateral side of body. This finding suggests that the molting of the 3rd stage larva of A. simplex to 4th one occurred from the 3rd day after infection in cats. The excretory organ (renette cell) consisted of a large cell with numerous ductules ramified from the main duct, mitochondria and secretory granules in cytoplasm. Secretory granules in the renette cell of larvae recovered at 24 hours PI were round whereas those of control and larvae recovered at 6 hours PI were amorphous. Muscular esophagus and ventriculus also retained many secretory granules in the cytoplasm. The secretory granules in these organs of larvae recovered at $6\sim24$ hours PI were electron-dense and widely distributed whereas those of control worm were packed in a pocket and retained various electron densities. In the cytoplasm of intestinal epithelial cells, numerous fine glycogen particles and mitochondria were distributed. The chronological changes of secretory granules in renette cell, muscular esophagus and ventriculus seem to be related with the worm penetration into host tissue.

  • PDF

Electrical Characteristics and System Efficiency of the 5.9kW Phosphoric Acid Fuel Cell Power Generation System (소형 인산형 연료전지발전 시스템의 출현 및 효율 특성)

  • 정두환;이원용;이선근;임희천;신동열;최수현
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.90-95
    • /
    • 1993
  • 수력, 화력, 원자력 다음으로 제 4의 전원으로서 관심의 대상이 되고 있는 연료전지는 연료가 가지고있는 화학에너지를 직접에너지로 변환시키는 점에서 종래의 발전 기술과는 원리적으로 다르며, 카르노(Carnot)사이클에 의한 에너지 변환 효율의 제한을 받지 않기 때문에 효율이 높으며 공해가 없는 특징을 가지고 있다. 연료전지의 발전 방식은 작동 온도, 전해질 등에 의해서 분류되나 현재 실용화단계의 기술은 인산형연료전지 발전이다. 인산형 연료전지의 발전용 연료는 천연가스, 메탄올, 납사 등과 같은 탄화수소 계열의 다양한 연료를 사용할 수 있으며, 이들 연료들을 수소가 많이 함유된 가스로 변환시켜 연료전지에 공급하여야 한다. 연료전지발전시스템 개발은 주로 전력이용 측면에서 천연가스를 개질연료로 사용하는 연구가 주류를 이루었으나, 최근에는 전 세계적으로 대기 공해에 시달리고 있는 도시의 환경개선을 위하여 도심용 버스 및 대형 트럭 등에 응용하기 위한 무공해 수송용 자동차엔진의 개발, 국방용 이동전원 개발 및 100㎾ 미만의 현지설치용 및 낙도용 전원으로서 메탄올을 연료로 한 연료전지의 개발이 활발히 진행되고 있다. 한국에너지기술연구소는 한국전력 기술연구원과 공동으로 1989년부터 1992년까지 본체를 제외한 5.9㎾급 인산형 연료전지 발전시스템 즉, 메탄올 연료 개질장치, 운전자동화 시스템, 배열이용 시스템, 종합 배관 등을 설계 구성하여 발전 플랜트의 운전 특성 연구를 수행하였으며, 본 고에서는 이들 설비들의 운전 특성과 발전 플랜트로서의 효율 특성에 대한 고찰을 수행하였다. 본 시스템은 연료개질기가 연결되고 배열을 이용하는 국내최초의 종합적인 연료전지 발전 시스템으로서 개질된 연료로 운전하였을 경우 본체의 효율은 31.9%, 배열을 회수한 종합발전 플랜트의 효율은 45.2%였다.로서, 흰쥐 유선이 LH의 생성처이면서 동시에 작용처이며 유선에서 합성된 GnRH의 조절하에 국부적인 인자로 작용할 가능성을 시사한다.f variation)가 10% 내외로 만족할 만한 범위에 들었다. 본 실험 방법을 타액과 혈청내 testosterone 농도 측정에 응용하여 RIA의 결과와 비교하여 본 바 상관관계가 타액에서 r=0.969, 혈청에서 r=0.990으로 두 결과가 잘 일치하였다. 본 실험에서 측정된 한국인 여성의 타액내 testosterone농도는 107.7$\pm$12.0 pmol/l이었고, 남성의 타액내 농도는 274.2$\pm$22.1 pmol/l이었다. 이상의 결과로 보아 본 연구에서 정립된 EIA 방법은 RIA를 대신하여 소규모의 실험실에서도 활용할 수 있을 것으로 사려된다.또한 상실기 이후 배아에서 합성되며, 발생시기에 따라 그 영향이 다르고 팽창과 부화에 관여하는 것으로 사료된다. 더욱이, 조선의 ${\ulcorner}$구성교육${\lrcorner}$이 조선총독부의 관리하에서 실행되었다는 것을, 당시의 사범학교를 중심으로 한 교육조직을 기술한 문헌에 의해 규명시켰다.nd of letter design which represents -natural objects and was popular at the time of Yukjo Dynasty, and there are some documents of that period left both in Japan and Korea. "Hyojedo" in Korea is supposed to have been influenced by the letter design. Asite- is also considered to have been "Jap

  • PDF

Performance Analysis of a 3 Pressured Combined Cycle Power Plant (3압 복합 발전 플랜트 사이클에 대한 성능해석)

  • Kim, S. Y.;K. S. Oh;Park, B. C.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.74-82
    • /
    • 1998
  • Combined cycle power plant is a system where a gas turbine or a steam turbine is used to produce shaft power to drive a generator for producing electrical power and the steam from the HRSG is expanded in a steam turbine for additional shaft power. The temperature of the exhaust gases from a gas turbine ranges from $400{\sim}650^{\circ}C$, and can be used effectively in a heat recovery steam generator to produce steam. Combined cycle can be classed as a topping and bottoming cycle. The first cycle, to which most of the heat is supplied, is a Brayton gas turbine cycle. The wasted heat it produces is then utilized in a second process which operates at a lower temperature level is a steam turbine cycle. The combined gas and steam turbine power plant have been widely accepted because, first, each separate system has already proven themselves in power plants as an independent cycle, therefore, the development costs are low. Secondly, using the air as a working medium, the operation is relatively non- problematic and inexpensive and can be used in gas turbines at an elevated temperature level over $1000^{\circ}C$. The steam process uses water, which is likewise inexpensive and widely available, but better suited for the medium and low temperature ranges. It therefore, is quite reasonable to use the steam process for the bottoming cycle. Recently gas turbine attained inlet temperature that make it possible to design a highly efficient combined cycle. In the present study, performance analysis of a 3 pressured combined cycle power plant is carried out to investigate the influence of topping cycle to combined cycle performance. Present calculation is compared with acceptance performance test data from SeoInchon combined cycle power plant. Present results is expected to shed some light to design and manufacture 150~200MW class heavy duty gas turbine whose conceptual design is already being undertaken.

  • PDF