• 제목/요약/키워드: 배열회수환기시스템

검색결과 3건 처리시간 0.016초

창호적용 배열회수 환기유닛의 열성능평가 연구 (A Study on Thermal Performance of the Heat Recovery Ventilator used Window)

  • 장철용;조수;성욱주;이진성
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.129-134
    • /
    • 2008
  • Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. And, recently the use of heat recovery ventilator has increased rapidly for improvement of air Quality and energy saving in building. But, the high efficient heat exchange will be more increasable than water vapors which were only occurred residential active. Purpose of this study is measurement of thermal performance about heat-recovery system integrated window. The result of the window thermal resistance is 1.80 $W/m^2K$ by KS F 2278. Air tightness is 5.96 m3/m2h at 4 Pa by KS F 2292.

  • PDF

창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가 (An Analysis on Thermal Performance and Economic of Heat Recovery Ventilation System Integrated with Window)

  • 성욱주;조수;송규동
    • 설비공학논문집
    • /
    • 제24권8호
    • /
    • pp.646-655
    • /
    • 2012
  • This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to $1.8W/m^2K$, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of '600,000 won/unit' for initial cost, 10 years for useful life of the system.

5톤/일 하향류식 가스화기를 이용한 폐목재 가스화 열병합 발전기술 연구 (A Study on Cogeneration System Using 5ton/day Scale Downdraft Waste Wood Gasifier)

  • 윤상준;김용구;이재구;김기세;강병찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.174.2-174.2
    • /
    • 2011
  • 최근 유가상승과 석유, 천연가스의 가채 매장량의 한계등과 함께 온실가스에 의한 지구온난화 방지를 위하여 미국, 유럽국가 및 캐나다 등에서는 바이오매스를 이용한 에너지 회수 기술개발에 많은 관심과 연구를 수행하고 있다. 바이오 매스는 에너지 밀도 대비 존재하는 지역이 광범위하여 발생, 수집, 수송에 따른 비용이 많이 소요되는 특성이 있어 산지에서 직접처리하거나 수집하여 대규모처리등과 같이 여러 가지 현장상황에 따라 적정한 플랜트 운용의 유연성을 갖추고 있어야 한다. 일반적으로 바이오매스로부터 중소형으로 분산형 발전이나 수소제조를 위해서는 직접 연소법 보다는 가스화 방식을 이용하고 있는데, 연소에 의해 열을 생산하여 전기를 생산하는 방식은 스팀터빈을 이용하는 것이며, 스팀터빈은 소형 운용이 어렵기 때문이다. 본 연구에서는 폐목재로부터 합성가스제조를 위하여 5톤/일 규모 가스화기를 제작하였으며, 타르 및 수트와 같은 미반응 물질을 제거할 수 있는 집진, 세정장치를 설계 및 제작하였다. 또한 합성가스에 함유된 현열로부터 열회수를 위하여 열교환기를 설치하였으며, 정제된 합성가스를 이용하는 가스엔진을 통하여 열병합 발전시스템 연계운전을 수행하였다. 운전 실험을 폐목재 가스화 3톤/일 규모로 수행하였으며, 평균 1,500kcal/$Nm^3$의 발열량을 갖는 합성가스를 생성시킬 수 있었다. 사이클론, 스크러버 및 기수분리 장치를 이용하여 정제된 합성가스는 합성가스 엔진을 통하여 72kW 이상의 전력생산이 가능하였다. 열교환기를 통하여 평균 15,000kcal/h의 배열 회수가 가능하였으며, 바이오매스 가스화 합성가스를 이용한 열병합 발전이 가능함을 입증하였다.

  • PDF