• Title/Summary/Keyword: 배연탈질설비

Search Result 8, Processing Time 0.024 seconds

A Study on the Economic Analysis of Low-Temperature SCR Technology for NOx Reduction by Scenarios (배연탈질을 위한 저온 SCR 기술 도입에 따른 시나리오별 경제성 분석)

  • Hong, Sungjun;Lee, Youah;Jeong, Soonkwan
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.10-22
    • /
    • 2020
  • As the national demand for solving the fine dust problem has increased, the government has announced intensive measures to deal with fine dust. So recently, selective catalytic reduction(SCR) has attracted attention as a technology for removing nitrogen oxides from precursors of fine dust. In this study, the government's policies related to fine dust and the current status of market and R&D were investigated, and economic analysis by scenarios was conducted by dividing cases where SCR technology was applied to industries. The results of economic analysis for each scenario were calculated using NPV, and companies with no denitrification facilities(Case 1) introduced general SCR technologies(Scenario 1-1) and low-temperature SCR technologies(Scenario 1-2). In addition, companies that have already installed denitrification facilities(Case 2) analyzed the two categories, using the general SCR technology as it is(Scenario 2-1) and replacing it with low-temperature SCR technology(Scenario 2-2). Comparative analysis was performed based on the results of each NPV.

Additive effects on $SO_x/NO_x$ removal characteristics using plasma (첨가제 활용에 따른 플라즈마 배연탈황탈질 특성)

  • 지평삼;엄희문;장경룡;남창모;지준화;한영욱
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.260-261
    • /
    • 1999
  • 산업시설 및 대형 발전설비에서 배출되는 아황산가스 및 질소산화물은 대기환경에 직접적으로 악영향을 미칠 뿐만 아니라, 오존의 생성과 고갈, 산성비의 출현등으로 지구 온난화와 같은 기후변화에 크게 기여하는 것으로 보고되고 있다. 기존의 습식 석회/석회석 탈황공정(FGD) 및 선택적 촉매/비촉매 탈질기술(SCR/SNCR)은 효과적인 상용기술로서 널리 연구개발되어 왔으나, 대단위 시설투자와 고비용, 2차 오염물질의 배출이 단점으로 지적되고 있다(Nam, 1999).(중략)

  • PDF

Comparison of Ammonia Mass Flow Rate between Two Ammonia Injection Positions in DeNOx system of a Horizontal HRSG (수평형 HRSG의 탈질설비에서 암모니아 분사위치 변동에 따른 암모니아 유량비교)

  • Park, Jae-Hyun;Yoo, Hoseon
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.48-54
    • /
    • 2018
  • As the emission limits for NOx in power generation facilities were strengthened, HRSGs installed in the 1990s became necessary to install additional DeNOx system. However, since there is no space in the HRSG for installing the entire the catalyst and ammonia injection grid, as an alternative, the catalyst was installed inside of the HRSG and the ammonia injection device was installed in the exhaust duct of the gas turbine. Experiments were conducted in horizontal HRSG of Incheon combined cycle power plant. Experimental results show that the ammonia injection method in the gas turbine exhaust duct is 1.2 times higher than the HRSG internal ammonia injection method. However when operating a HRSG for 30 years as its life span, ammonia injection method in the gas turbine exhaust duct is more economical than the cost of new HRSG construction.

  • PDF

Practical Study of the Thermal Efficiency Improvement and the White Plume Removal from Flue Gas by Fuel Additive Injection (연료첨가제를 이용한 열효율향상 및 가시백연 제거에 관한 연구)

  • 전상기;조승원;황영호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.487-488
    • /
    • 2003
  • 우리나라 대기환경기준이 점차 강화되고 있고, 국민의 욕구수준 또한 선진국 수준으로 강화될 계획으로 있어 이에 따른 대기오염 방지시설의 설치 또는 보완이 요구되고 있다 특히, 배기가스 중 황산화물 및 질소산화물 배출농도 강화로 울산화력발전소에서는 최신의 배연탈황ㆍ탈질설비를 가동중에 있으나 황산 Mist가 주요원인으로 추정되는 Plume Opacity가 발생되어 오염물질 배출농도는 법적규제기준 이내로 배출되더라도 민원이 발생되고 있다. 이에 대한 대책으로 현장에 적합한 연료첨가제 주입으로 Plume Opacity 발생원인을 제거함과 동시에 배연탈황설비에서 발생된 저온부식 현상을 개선하고, 보일러 내 고온부식 등 연소장애 현상 개선을 통한 열효율 향상 방안에 대해 연구하였다. (중략)

  • PDF

A Study on the Flue Gas Mixing for the Performance Improvement of De-NOx plant (배연탈질설비의 성능향상을 휘한 가스혼합에 관한 연구)

  • 류병남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.462-472
    • /
    • 1999
  • De-NOx facility using Selective Catalytic Reduction method is the most widely applied one that removes NOx from flue gas emitted from combustion facility such as boiler for power generation engine incinerator etc. Reductant $NH_3\;or\;NH_4OH$ is sprayed into flue gas to convert NOx into $H_2O$ and $N_2.$ Good mixing between flue gas and $NH_3$ is the most important factor to increase reduction in catalytic layer and to reduce unreacted NH3 slip. Therefore the development of mixer device for mixing effect is one of the important part for SCR facility. Objectives of this study are to investigate the relation between flow and concentration field by observation at the wake of delta-wing type mixer. At the first stage qualitative measurement of flow field is conducted by flow visualization using laser light sheet in lab. scale wind tunnel. Also we have conducted the quantitative analysis by comparing flow field measurement using LDV with numerical simulation. On the basis of qualitative and quantitative analysis we investigate the dis-tribution of flow and concentration in flow model facility. The results of an experimental and compu-tational examination of the vortex structures shed from delta wing type vortex generator having $40^{\circ}$ angle of attack are presented, The effects of vortex structure on the gas mixing is discussed, too.

  • PDF

Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process (저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발)

  • Yoo, J.S.;Paek, M.S.;Kim, T.H.;Kim, J.I.;Kim, Y.S.;Choi, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

Deactivation of $V_2O_5/TiO_2$ catalyst used in Orimulsion Fuel Power Plant for the Reduction of Nox (배연 탈질용 $V_2O_5/TiO_2$ 촉매의 오리멀젼 연소에 의한 비활성화)

  • Lee, In-Young;Lee, Jung-Bin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.54-60
    • /
    • 2008
  • Deactivation of SCR catalyst applied in Orimusion fuel power plant was investigated to develope the technique for the regeneration of deactivated SCR catalyst and optimize the operation of SCR facility. The characterization study of the catalysts was carried out using XRD, ICP-AES, SEM and EDS. The NO$_X$ removal activity and SO$_2$ oxidation activity of the catalysts were measured. The NO$_X$ conversion of the deactivated catalyst was 5$\sim$10% lower than that of the fresh catalyst and the value of SO$_2$conversion to SO$_3$ over the deactivated catalyst was about 0.59% higher than that of the fresh catalyst. Vanadium(V), Magnesium(Mg) and Sulfur(S) were largely accumulated in the deactivated catalyst. The accumulation of Vanadium(V) and Sulfur(S) is due to the components of the Orimulsion fuel and the accumulation of Magnesium(Mg) is due to MgO that is injected in the boiler to prevent the oxidation of SO$_2$ to SO$_3$. The diffraction line of the TiO$_2$ of the deactivated catalyst was identified as the crystalline peaks of anatase as the fresh catalyst.

Modeling of Damage Effects Caused by Ammonia Leakage Accidents in Combined Cycle Power Plant (복합화력발전소 내 암모니아 누출 사고에 의한 피해영향 모델링)

  • Eun-Seong Go;Kyeong-Sik Park;Dong-Min Kim;Young-Tai Noh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.3
    • /
    • pp.1-15
    • /
    • 2023
  • This study focuses on modeling the impact of ammonia leakage from the storage tank in a combined cycle power plant's flue gas denitrification facility. It employs accident impact assessments and diffusion models to determine the optimal scenarios for ammonia storage tank leakage accidents. The study considers the operating conditions of variables as standard conditions for predicting the extent of damage. The Taean combined cycle power plant is chosen as the target area, taking into account seasonal factors such as temperature, humidity, wind speed, atmospheric stability, and wind direction. By utilizing a Gaussian diffusion model, the concentration of ammonia gas at various locations is estimated to assess the potential extent of external damage resulting from a leak. The study reveals that in conditions of high temperature and stable atmosphere within the specified range, lower wind speeds contribute to increased damage to the human body due to ammonia diffusion.