• Title/Summary/Keyword: 배수성

Search Result 1,900, Processing Time 0.036 seconds

Indirect ELISA Method for Measurement of Lactoperoxidase using IgY Antibody (IgY 항체를 이용하여 Lactoperoxidase 정량을 측정하기 위한 Indirect ELISA 방법의 개발)

  • 이승배;최석호;최재원
    • Food Science of Animal Resources
    • /
    • v.24 no.2
    • /
    • pp.182-188
    • /
    • 2004
  • To determine the concentration of Lactoperoxidase (LPO), an indirect enzyme-linked immunosorbant assay(ELISA) was developed. Anti-LPO egg yolk immunoglobulin(IgY) was transferred to egg yolk by immunizing of Brown hens with LPO. The titer of purified anti-LPO IgY was 1: 520,000. The immunological response of anti- LPO IgY with ${\alpha}$-lactalbumin, ${\beta}$-lactoglobulin, casein and lysozyme were evaluated, resulting that the anti-LPO IgY found to be a specific antibody toward LPO and no cross-reaction was observed against ${\alpha}$-lactalbumin, ${\beta}$-lactoglobulin, casein, and lysozyme in double immunodiffusion test and ELISA test. In indirect ELISA method, coating concentration of LPO and dilution rate of anti-LPO IgY was 0.25$\mu\textrm{g}$/mL and 1:8,000 respectively. Sensitivity in the standard curve of LPO was ranged from 0.01 to 1$\mu\textrm{g}$/mL using anti-LPO IgY.

A Method on Discharge Computation of Backwater by Handle of Gate (갑문조작에 의한 배수영향을 받는 지점의 유량산정 방법)

  • Lee, Chung-Dae;Han, Hak-Young;Lim, Tae-Eun;Choi, Hyuk-Joon;Jeong, Seong-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.421-425
    • /
    • 2009
  • 수자원의 효율적인 관리를 위해서는 홍수량 자료뿐만 아니라 저 평수량의 자료도 매우 중요하며, 이는 최근의 가뭄 발생으로 인하여 용수공급 및 하천수질관리 문제에서 저수위 유량자료의 파악이 중요한 관심 대상이기 때문이다. 이를 위해서는 저수위에 대해 유량측정을 실시하여 유량자료를 확보해야 하며, 이와 더불어 연속적인 유량자료를 얻기 위해서는 신뢰성 있는 수위-유량관계곡선식이 필수적이다. 일반적으로 자연하천에서 수위-유량관계는 수위의 상승 및 하강에 따라 유량변화가 일정한 경향성을 가지고 변동을 하기 때문에 단일함수 관계로 설명이 가능하다. 하지만 갑문 조작에 영향을 받는 구간에서는 수위와 유량만의 단일함수 관계가 아닌 갑문의 개 폐에 따라 수위와 유량이 변동하는 특성을 가지고 있어 일반하천에 비해 수위-유량관계를 규명하는 것이 매우 어려운 문제이다. 최근에 ADCP(Acoustic Doppler Current Profiler) 및 유속지수법을 이용한 자동유량측정시설이 국내에 도입됨에 따라 저 평수량에 대한 연속측정이 가능하게 되었으나, 측정된 수위-유량자료를 이용하여 수위-유량관계곡선식을 개발하는 것은 아직까지 국내 외를 막론하고 명확히 해결하지 못하는 문제점이 남아 있다. 본 연구는 갑문의 조작에 따라 크게 영향을 받는 저 평수량에 대하여 수위-수면경사-유량관계를 이용한 산정방법과 자동유량측정시설에 의한 유량산정방법에 대하여 비교 검토하였으며, 이를 검증하기 위하여 ADCP(Acoustic Doppler Current Profiler)를 이용하여 갑문 개 폐에 따른 연속 측정을 수행하였다. 이와 같은 유량 산정방법과 검증을 통하여 보다 신뢰도가 높은 저 평수량을 산정하는 것이 목적이다.

  • PDF

A study on a ballast optimization algorithm for onboard decision support system (선내탑재 의사결정지원 시스템을 위한 발라스트 최적화 알고리즘에 관한 연구)

  • Shin Sung-Chul
    • Journal of Navigation and Port Research
    • /
    • v.29 no.10 s.106
    • /
    • pp.865-870
    • /
    • 2005
  • Because there are only a limited number of means of action that are available for the master to pursue in the event of flooding, onboard decision support system has been required. The majority of systems activated during a flooding emergency (such as watertight and semi-watertight doors, bulkhead valves, dewatering pumps etc.) almost exclusively aim to restore a sufficiently high level of subdivision to prevent flooding from spreading through the ship. Even though assuming the flooding scenario is not catastrophic, the use of ballast tanks can be an additional and very effective tool to ensure both prevention of flooding spreading and also improve ship stability. This paper describes an optimization algorithm devised to choose the set of ballast tanks that should be filled in order to achieve an optimal response to a flooding accident.

Groundwater Flow Modeling for a Finite Unconfined Sandy Aquifer in a Laboratory Scale (사질 자유면 대수층 모형에서의 지하수 모델링)

  • 이승섭;김정석;김동주
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.188-193
    • /
    • 1999
  • Transport of pollutants in aquifer largely depends on groundwater flow which is governed by aquifer hydraulic parameters. Determination of these parameters and associated groundwater modeling become essential for adequate remediation of contaminate groundwater. The objective of this paper is to analyze groundwater flow and determine the optimum hydraulic parameters by performing groundwater modeling based on sensitivity analysis for unconfined sandy gavel aquifer constructed in a laboratory scale under various boundary condition. Results revealed that the simulated drawdown was lower than the observed drawdown irrespective of boundary conditions. and specific yield (S$_{y}$) had less effect on the grondwater flow than permeability (K) in the aquifer. Water balance analysis showed that the measured drawdown in neighboring observation wells during pumping was higher than either simulated or recovered water table. The indicated that a difference might exist in the water tables between aquifer and wells. The difference was investigated by time domain reflectometry (TDR) measurements on water contents in the region of water table and capillary fringe, and explained by a delayed response of water table during gravitational drainage as the water table was lowered as a result of pumping.g.

  • PDF

Bactericidal Efficacy of a Powder Disinfectant Containing Phosphate Compounds Against Salmonella Typhimurium

  • Park, Eun-Kee;Cha, Chun-Nam;Yoo, Chang-Yeul;Kim, Suk;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.6
    • /
    • pp.471-475
    • /
    • 2016
  • Salmonella Typhimurium (S. Typhimurium) is one of the common food pathogens which may cause gastroenteritidis in human and animals. The microorganism also causes the economic loss in animal farming and food industry. In this study, the disinfection efficacy of a powder disinfectant containing phosphate compounds as a main ingredient, was evaluated against S. Typhimurium. A bactericidal efficacy test by broth dilution method was used to determine the lowest effective dilution of the disinfectant following exposure to test bacteria for 30 min at $4^{\circ}C$. The disinfectant and test bacteria were diluted with hard water (HW) or organic matter suspension (OM) according to treatment condition. On HW and OM conditions, the bactericidal activity of the disinfectant against S. Typhimurium was 4- and 2-fold dilutions, respectively. As the disinfectant composed to phosphate compounds possesses bactericidal efficacy against pathogenic bacteria such as S. Typhimurium, the powder disinfectant can be used to control the spread of bacterial diseases.

Technical Analysis on Existing Ship's Economical Operation (운항선 중심의 선박 경제운항 관리의 기술적 분석)

  • Kang, Nam-seon;Kim, Yong-dae;Yoon, Hyeon-kyu;Byeon, Sang-su
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.519-527
    • /
    • 2016
  • The present study is concept research on the operation cost management of shipping firms, especially considering technology for economical ship operation of existing ships in units of voyage. The factors that influence economical ship operation management were identified by analyzing the current status of the shipping industry, the development of economical ship operation technologies, technological requirements, and the cost factors of ship operation. Economical operation of existing ships, especially, the economical operation of the units of each voyage, may minimize fuel cost and port charges. This requires low-load streaming cruise control, ballast control, optimal trim, optimal routing, terminal work efficiency improvement, and ship energy management. Optimal routing and terminal work efficiency improvement manage the time saved. To determine the low-load streaming, cruise control, ballast control, optimal trim and ship energy management are meeting the recommendations.

Stabilization of Ascorbic acid with Nonaqueous Emulsification (비수 유화법을 이용한 아스코르빅산의 안정화)

  • Lee, Chung Hee;Shin, Jae Dong;Bae, Su Hyun;Kang, Ki Choon;Pyo, Hyeong Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.263-270
    • /
    • 2012
  • Ascorbic acid (Vitamin C) becomes unstable in the aqueous phase by oxygen, light and alkali, etc. The properties are limited in application to cosmetics. The most important factor that determines the destabilization of ascorbic acid in the aqueous phase was tried to understand considering its molecular deformation and degradation. In this study, we changed the polyols and emulsification technique for the stability of ascorbic acid. Then we observed the color and concentration change of ascorbic acid at room temperature and high temperature ($42^{\circ}C$) for 6 weeks and identified the stability using HPLC regularly. As a result, we found that glycerin was the most appropriate polyol for stability of the ascorbic acid. Also the technique of nonaqueous emulsification stabilized ascorbic acid than P/S emulsification. Also, P/S emulsification, glycerin was more stable than propylene glycol. By the results we suggest that ascorbic acid could be stabilized by nonaqueous emulsification method and this data could be applied to stabilization methods for cosmetic products.

Behavior of the Embankment on Normally Consolidated Clay Supported by the Piled Raft (Piled Raft 기초로 지지된 연약지반 상의 제방의 거동)

  • Kim, Sang-Kyu;Song, Sun-Ok;Han, Sung-Gil;Jeon, Jin-Kyu;Lee, Wan-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.4
    • /
    • pp.33-41
    • /
    • 2011
  • A railway embankment route extending to 2 km was laid on normally consolidated clay in the West Gimhae Plain. This embankment was first built using the stage-construction technique, but longitudinal cracks suggesting arc sliding appeared on the surface of the embankment immediately after the first stage of its construction. As an alternative, the piled raft was installed on the failed embankment and then the remaining height of the embankment was raised. The behavior of the piled raft was monitored with different instruments during construction. This paper describes the monitoring results and analyses. The results show that if the pile group essentially exhibits the behavior of friction piles, the piled raft foundation performs well even in normally consolidated soft clay.

Hydration Heat and Crack-Reducing Properties of Cement Mortar Added Fluosilicate Salt Based Hydration Heat Reducer (규불화염계 수화열 저감제가 첨가된 시멘트 모르타르의 수화열 변화 및 균열저감 특성)

  • Kim, Jin-Yong;Lee, Hyo-Song;Rhee, Young-Woo;Kim, Do-Su;Lee, Byoung-Ky;Khil, Bae-Su;Han, Seung-Gu
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.3 s.274
    • /
    • pp.198-204
    • /
    • 2005
  • Fluosilicate salts based hydration heat reducer(SWP-HR), used in this study, is composed of fluosilicate salts, soluble silica, aromatic polymer condensate and nitrate salt based inorganic compound with latent heat property. Effects of SWP-HR addition on the hydration heat and anti-crack property of cement mortar were investigated. Adiabatic hydration temperature and drying shrinkage length of SWP-HR added cement mortar had a tendency to decrease compared to those of cement mortar without SWP-HR addition. Also, it was confirmed through crack pattern experiment of plate-form specimen for elucidating crack-reducing characteristic that anti-crack property of SWP-HR added cement mortar was improved.

Determination of Consolidation Characteristics of Clayey Soils from the Self-boring Pressuremeter Test (자가굴착식 프레셔미터 시험을 이용한 점성토의 압밀특성 산정)

  • 장인성;정충기;김명모;조성민
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.87-96
    • /
    • 2002
  • The strain holding test(SHT) or the sell-boring pressuremeter test(SBPT) has been effectively utilized to determine the horizontal coefficient of consolidation$(c_h)$ of clayey soils. However, a commonly used procedure proposed by Clarke et al.(1979) can lead to an erroneous estimation of $(c_h)$ because of its simplified assumptions. This paper deals with numerical analyses based on realistic test conditions of the generally accepted testing procedure, and .using the most commonly used type of pressuremeter. The effects of pressuremeter geometry, partial drainage during cavity expansion, and the cavity strain level for the holding test are investigated with the radial distributions of the initial excess pore pressure and their dissipation rate. Based on the results of the numerical analyses, the curve of the time factor for the 50% degree of consolidation($T_{50}$) needed to estimate $(c_h)$ is proposed. Comparisons are made between $(c_h)$ values estimated from the SHT or the SBPT and those obtained from other in situ and laboratory tests performed at two sites in Korea. These results suggest the improved capability of the $T_{50}$ curve proposed herein.