• Title/Summary/Keyword: 배수분구

Search Result 48, Processing Time 0.022 seconds

Accuracy Improvement of Urban Runoff Model Linked with Optimal Simulation (최적모의기법과 연계한 도시유출모형의 정확도 개선)

  • Ha, Chang-Young;Kim, Byunghyun;Son, Ah-Long;Han, Kun-Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.215-226
    • /
    • 2018
  • The purpose of this study is to improve the accuracy of the urban runoff and drainage network analysis by using the observed water level in the drainage network. To do this, sensitivity analysis for major parameters of SWMM (Storm Water Management Model) was performed and parameters were calibrated. The sensitivity of the parameters was the order of the roughness of the conduit, the roughness of the impervious area, the width of the watershed, and the roughness of the pervious area. Six types of scenarios were set up according to the number and types of parameter considering four parameters with high sensitivity. These scenarios were applied to the Seocho-3/4/5, Yeoksam, and Nonhyun drainage basins, where the serious flood damage occurred due to the heavy rain on 21 July, 2013. Parameter optimization analysis based on PEST (Parameter ESTimation) model for each scenario was performed by comparing observed water level in the conduits. By analyzing the accuracy of each scenario, more improved simulation results could be obtained, that is, the maximum RMSE (Root Mean Square Error) could be reduced by 2.41cm and the maximum peak error by 13.7%. The results of this study will be helpful to analyze volume of the manhole surcharge and forecast the inundation area more accurately.

Inundation Analysis in Urban Area Considering of Head Loss Coefficients at Surcharged Manholes (과부하 맨홀의 손실계수를 고려한 도시지역 침수해석)

  • Lee, Won;Kim, Jung Soo;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • In general, XP-SWMM regards manholes as nodes, so it can not consider local head loss in surcharged manhole depending on shape and size of the manhole. That might be a reason why XP-SWMM underestimates inundated-area compared with reality. Therefore, it is necessary to study how we put the local head loss in surcharged manhole in order to simulate storm drain system with XP-SWMM. In this study, average head loss coefficients at circular and square manhole were estimated as 0.61 and 0.68 respectively through hydraulic experiments with various discharges. The estimated average head loss coefficients were put into XP-SWMM as inflow and outflow energy loss of nodes to simulate inundation area of Gunja basin. Simulated results show that not only overflow discharge amount but inundated-area increased considering the head loss coefficients. Also, inundation area with considering head loss coefficients was matched as much as 58% on real inundation area. That was more than simulated results without considering head loss coefficients as much as 18 %. Considering energy loss in surcharged manholes increases an accuracy of simulation. Therefore, the averaged head loss coefficients of this study could be used to simulate storm drain system. It was expected that the study results will be utilized as basic data for establishing the identification of the inundation risk area.

Development of flood forecasting system on city·mountains·small river area in Korea and assessment of forecast accuracy (전국 도시·산지·소하천 돌발홍수예측 시스템 개발 및 정확도 평가)

  • Hwang, Seokhwan;Yoon, Jungsoo;Kang, Narae;Lee, Dong-Ryul
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.3
    • /
    • pp.225-236
    • /
    • 2020
  • It is not easy to provide sufficient lead time for flood forecast in urban and small mountain basins using on-ground rain gauges, because the time concentration in those basins is too short. In urban and small mountain basins with a short lag-time between precipitation and following flood events, it is more important to secure forecast lead times by predicting rainfall amounts. The Han River Flood Control Office (HRFCO) in South Korea produces short-term rainfall forecasts using the Mcgill Algorithm for Precipitation-nowcast by Lagrangian Extrapolation (MAPLE) algorithm that converts radar reflectance of rainfall events. The Flash Flood Research Center (FFRC) in the Korea Institute of Civil Engineering and Building Technology (KICT) installed a flash flood forecasting system using the short-term rainfall forecast data produced by the HRFCO and has provided flash flood information in a local lvel with 1-hour lead time since 2019. In this study, we addressed the flash flood forecasting system based on the radar rainfall and the assessed the accuracy of the forecasting system for the recorded flood events occurred in 2019. A total of 31 flood disaster cases were used to evaluate the accuracy and the forecast accuracy was 90.3% based on the probability of detection.

Development of Grid based Inundation Analysis Model (GIAM) (격자기반 침수해석모델(GIAM) 개발)

  • Lee, Byong Ju;Yoon, Seong Sim
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.3
    • /
    • pp.181-190
    • /
    • 2017
  • Population congestion and increasing porosity caused by urbanization and increasing rainfall intensity are the main reasons for urban inundation damage. In order to reduce the damage to urban flooding, it is necessary to take a inundation analysis model that can be considered the topographic impact (i.e., building and road) and simulate the detailed inundation areas. In this study, Grid based Inundation Analysis Model (GIAM) is developed using a two-dimensional shallow water equations. The study area is Gangnam basin, with a surface area of $7.4km^2$, which includes 5 drainage areas such as Nonhyun, Yeoksam, Seocho 1, 2, and 3. EPA SWMM5 is used for simulating the overflows at each manhole. GIAM model is constructed to allow for simulating a inundation area with 6 m grid size. The inundation analysis is conducted in two heavy rainfall events (Sep. 21, 2010 and July 27, 2011) for the model evaluation. The accuracy of the simulated inundation area is calculated 0.61 and 0.57 at POD index using the historical flooded area report. The developed model will be used as a tool for analyzing the flood prone areas based on rainfall scenario, and a tool for predicting the detailed inundation area in the real-time.

Identifying Cost and Benefit Items of Investment Projects to Offer New Public Services By the Use of Food Waste Disposers and the Direct Input of Feces in Sewers (주방오물분쇄기 사용 및 수세분뇨의 직투입에 따른 「새로운 공공하수도 서비스」제공을 위한 투자사업의 비용과 편익 항목 식별)

  • Oh, Hyun-Taek;Park, Kyoo-Hong;Kim, Sung Tai;Lim, Byung In
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.5
    • /
    • pp.117-125
    • /
    • 2020
  • Our study identifies a cost and a benefit incurred in implementing an investment project to offer new public services by use of food waste disposers and direct input of feces in sewers. This is done with identifying costs of each processing division and benefits of the project by objective statistical data and engineering perspective. In summary, cost items identified are as follows: there are house laterals, removal of septic tanks, etc. for sewer pipes system. As to water quality conservation, cost incurs in storm water outfalls and divert chambers, sewage storage tanks, equipment to treat sewer overflows, and so on. With respect to sewage treatment plants(STPs), there are so many items as increase of contaminant loads in influent of STPs, and other items. There are benefit items in health improvement due to odor mitigation, increase of energy productivity, saving cost of food waste treatment and cleaning septic tanks, etc. These estimates will be used as a basic data for its economic effect.

Runoff analysis according to LID facilities in climate change scenario - focusing on Cheonggyecheon basin (기후변화 시나리오에서의 LID 요소기술 적용에 따른 유출량 분석 - 청계천 유역을 대상으로)

  • Yoon, EuiHyeok;Jang, Chang-Lae;Lee, KyungSu
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.583-595
    • /
    • 2020
  • In this study, using the RCP scenario for Hyoja Drainage subbasin of Cheonggyecheon, we analyzed the change with the Historical and Future rainfall calculated from five GCMs models. As a result of analyzing the average rainfall by each GCMs model, the future rainfall increased by 35.30 to 208.65 mm from the historical rainfall. Future rainfall increased 1.73~16.84% than historical rainfall. In addition, the applicability of LID element technologies such as porous pavement, infiltration trench and green roof was analyzed using the SWMM model. And the applied weight and runoff for each LID element technology are analyzed. As a result of the analysis, although there was a difference for each GCMs model, the runoff increased by 2.58 to 28.78%. However, when single porous pavement and Infiltration trench were applied, Future rainfall decreased by 3.48% and 2.74%, 8.04% and 7.16% in INM-CM4 and MRI-CGCM3 models, respectively. Also, when the two types of LID element technologies were combined, the rainfall decreased by 2.74% and 2.89%, 7.16% and 7.31%, respectively. This is less than or similar to the historical rainfall runoff. As a result of applying the LID elemental technology, it was found that applying a green roof area of about 1/3 of the urban area is the most effective to secure the lag time of runoff. Moreover, when applying the LID method to the old downtown area, it is desirable to consider the priority order in the order of economic cost, maintenance, and cityscape.

Comparing Methods for Determining Flood Protection Elevation in Urban Built-up Areas (도시지역 방어침수위 설정방법 비교분석)

  • Lee, Yang Jae;Shin, Sang Young;Lee, Chang Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3B
    • /
    • pp.271-281
    • /
    • 2008
  • To determine the flood protection elevation (FPE) in urban built-up areas, this study examines four possible methods: using the highest flood elevation in the past, extending base flood elevations of nearby watercourse to inland, and two simulation methods of inland flood under the same rainfall used in the watercourse planning nearby. According to the case study of the Jang-An Drainage Area, Seoul, the highest flood elevation in the past and simulation results of inland flood under the same rainfall in the watercourse planning nearby tend to get similar results, while extending base flood elevations of nearby watercourse to inland shows much higher elevations than other results. Meanwhile, cost-benefit analysis, when regulating residential/commercial uses below the FPE by each of four methods, suggest that planners need to consider carefully the economic feasibility of FPE used to choose appropriate methods.

Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District (하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구)

  • Shin, Hyun Suk;Kim, Mi Eun;Kim, Jae Moon;Jang, Jong Kyung
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1193-1207
    • /
    • 2013
  • Increase of impervious area caused by overdevelopment has led to increase of runoff and then the problem of flooding and NPS were brought up. In addition, as decrease of base flow made groundwater level to decline, a stream that dries up is issued. low impact development (LID) method which is possible to mimic hydrological water cycle, minimize the effect of development, and improve water cycle structure is proposed as an alternative. As introduction of LID in domestic increases, the study on small watershed is in process mainly. Also, analysis of property of hydrological runoff and load on midsize watershed, like sewage treatment district, is required, the study on it is still insufficient. So, area applying LID practices from watershed of Dongrae stream is pinpointed and made the ratio and then expand it to watershed of Oncheon stream. Among low impact development practices, Green Roof, Porous Pavement, and Bio- retention are selected for the application considering domestic situations and simulated with SWMM-LID model of each watershed and improvement of water cycle and reduction of non-point pollution loads was analysed. Improvement of water cycle and reduction of non-point pollution loads were analyzed including the property of rainfall and soil over long term simulation. The model was executed according to scenario based on combination of LID as changing conductivity in accordance with soil type of the watershed. Also, this study evaluated area of LID application that meets the efficiency of conventional management as a criteria for area of LID practices applying to sewer treatment district by comparing the efficiency of LID application with that of conventional method.