• Title/Summary/Keyword: 배수공법

Search Result 283, Processing Time 0.027 seconds

Consolidation Analysis of Vertical Drain Considering Artesian Pressure (피압수압을 고려한 연직배수공법의 압밀해석)

  • 김상규;김호일;홍병만;김현태
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.02a
    • /
    • pp.62-70
    • /
    • 1999
  • Artesian pressure exists in Yangsan site, the maximum value of which has been measured as high as 5 t/m$^2$. This paper deals with the prediction of consolidation settlement for the site with artesian pressure. The consolidation settlement at the site has been accelerated using vertical band drains. Since the artesian pressure gives lower effective stress than a static condition, its effect should be considered in the settlement prediction. This case study shows that the prediction of settlement and pore pressure dissipation agrees well with the measurements, when considering the artesian effect.

  • PDF

A Case Study on Test Embankment using Vertical Drain Method at Incheon International Airport (인천국제공항 수직배수공법 시험시공 사례연구)

  • 권오현
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.06a
    • /
    • pp.33-44
    • /
    • 2001
  • The generally known vertical drain methods for improvement of soft ground are Sand Drain, Sand Compaction Pile, Plastic Drain Board, and Pack Drain. Recently, Plastic Drain Board method application in soft ground is widely used. In this case study, it is compared with each other vertical drain methods from the results of monitorning and test embankment. The results of the analysis and the study show that Plastic Drain Board method is relatively acceptable as vertical drain method.

  • PDF

Assessment and Damage Reduction Strategy of Acid Rock Drainage in Highway Construction Site: ○○ Highway Construction Site (고속도로 건설현장의 산성배수 발생개연성평가 및 피해저감대책: ○○고속도로건설현장)

  • Lee, Jin-Soo;Kim, Jae Gon;Park, Jeong-Sik;Chon, Chul-Min;Nam, In-Hyun
    • Economic and Environmental Geology
    • /
    • v.46 no.5
    • /
    • pp.411-424
    • /
    • 2013
  • Assessment and damage reduction strategy of acidic rock drainage were conducted in a section of ${\bigcirc}{\bigcirc}$ highway construction site. The geology of the studied section consists of Icheonri sandstone and intermediate to acidic volcanic rocks. Sulfides occur as a disseminated type in sandstone and volcanics which were altered by the hydrothermal solution of granite intrusion. Volcanics and sandstone with a high content of sulfide were classified as a potentially acid rock drainage(ARD) forming rock. The drainage originated from those rocks may acidify and contaminate the surrounding area during the highway construction. Therefore, the drainage should be treated before it is discharged. A slope landslide hazard due to the ARD was also expected and the coating technology was recommended for the reduction of ARD generation as a preemptive measure before reinforcement work for enhancing slope stability such as shotcrete and anchor. According to the ARD risk analysis, those rocks should not be used as cement aggregate, but only to be used as a bank fill material of a filling-up system that allows minimal contact with rainfall and groundwater.

Assessment of Acid Rock Drainage Production Potential and Damage Reduction Strategy: A Case Study of Tunnel Construction Area (암석의 산성배수 발생개연성 평가 및 피해저감대책: 터널건설예정구간 사례)

  • Kim, Jae-Gon;Lee, Jin-Soo;Kim, Tong-Kwon
    • Economic and Environmental Geology
    • /
    • v.41 no.3
    • /
    • pp.335-344
    • /
    • 2008
  • The acid rock drainage (ARD) production potential of rock was assessed for a tunnel construction area, Kimhae and the damage reduction strategy was discussed based on the ARD risk evaluation. The geology of the studied area consisted of Mesozoic quartz porphyry, sandstone, tuff and granite. Sulfides occurred as a disseminated type in quartz porphyry and granite, and a vein type in sandstone. Quartz porphyry and sandstone with a high content of sulfide were classified as a potentially ARD forming rock. The drainage originated from those rocks may acidify and contaminate the surrounding area during the tunnel construction. Therefore, the drainage should be treated before it is discharged. A slope stability problem due to the ARD was also expected and the coating technology was recommended for the reduction of ARD generation before the application of supplementary work for enhancing slope stability such as shotcrete and anchor. From the ARD risk analysis, those rocks should not be used as aggregate and be used as bank fill material with the system for the minimum contact with rain water and ground-water.

Characteristics of Lateral Flow due to Embankments for Road Construction on Soft Grounds Using Vertical Drain Methods (연직배수공법이 적용된 연약지반 상에 도로성토로 인한 측방유동의 특성)

  • Hong, Won-Pyo;Kim, Jung-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.9
    • /
    • pp.5-15
    • /
    • 2012
  • Field monitoring data for embankments in thirteen road construction sites at coastal area of the Korean Peninsula were analyzed to investigate the characteristics of lateral flow in soft grounds, to which vertical drain methods were applied. First of all, the effect of the embankment scale on the lateral flow was investigated. Thicker soft soils and lager relative embankment scale produced more horizontal displacements in soft grounds. Especially, if thick soft grounds were placed, the relative embankment scale, which was given by the ratio of thickness of soft ground to the bottom width of embankments, became larger and in turn large horizontal displacement was produced. And also higher filling velocity of embankments induced more horizontal displacements in soft grounds. The other major factors affecting the lateral flow in soft ground were the thickness and undrained shear strength of soft grounds, the soil modulus and the stability number. Maximum horizontal displacement was induced by less undrained shear strength and soil modulus of soft grounds. Also more stability numbers produced more maximum horizontal displacements. When the shear deformation does not develop, the stability number was less than 3.0 and the safety factor of bearing was more than 1.7. However, if the stability number was more than 5.14 and the safety factor of bearing was less than 1.0, the unstable shear failure developed in soft ground. 50mm can be recommended as a criterion of the allowable maximum horizontal displacement to prevent the shear deformation in soft ground, while 100mm can be recommended as a criterion of the allowable maximum horizontal displacement to prevent the shear failure in soft ground.

Analysis on Impact Factors of Open-cut Type Excavation Work using Numerical Analysis Method (수치해석기법을 이용한 개착식 지반굴착공사의 영향인자 분석)

  • Seong, Joo-Hyun;Kim, Yong-Soo;Shin, Byoung-Gil
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.43-53
    • /
    • 2013
  • In this study, an analysis about the causes of different types of excavation on accidents is required in order to prevent the frequently occurring accidents related to the earth retaining structure and excavation. Also, analysis of influence was performed by using numerical typical soil conditions and construction trend using numerical analysis method. According to the analysis results of 25 accident cases, the main influence factors were found as following: insufficient of soil survey, instability of temporary facility and lack of groundwater treatment, etc. Furthermore, in the numerical analysis result of 22 cases, drainage method was occurred larger settlement than waterproof method in the Inland. In case of applying the earth anchor method, it needs more detailed in the regions, which are discovered soft ground or rock discontinuities. Also, The consolidated clay absolutely needs further consideration of excess hydrostatic pressure.

Characteristics on Electroosmosis Ground Improvement Using Nano-geosynthetics (나노섬유를 이용한 동전기 지반개량에 관한 특성)

  • Ahn, Kwangkuk;Jeong, Kusic;Lee, JunDae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.59-63
    • /
    • 2009
  • In this study, Nano-geosynthetics with electroosmosis method was used and tried to verify the possibility of usage for soft ground improvement. Electroosmosis tests were performed with increasing the voltage level and changing distance between electrodes. The electrokinetic cell was assembled and a Nano-geosynthetics was inserted into the plastic drain board. And electroosmosis was applied to the disturbed kaolin clay. In order to study the effects of ground improvement, ground settlement, water content, collected pore water and shear strength were compared and analyzed with non-applied kaolin clay. Also, the electroosmosis tests were performed with changing the distance between electrodes and the voltage size. As a results of changing the distance and voltage between electrodes, the more voltage size was increased, the more the settlement of ground, shear strength and collected pore water were increased. As the distance between electrodes were increased, the settlement of ground, shear strength, water content and collected pore water were decreased. Finally, Nano-geosynthetics as a material of electrode have the sufficient potential to improve soft ground.

  • PDF

A Study on the Consolidation Settlement Due to the Vertical Drain Method by the Implicit Finite Difference Scheme (음적차분해석법을 이용한 연직배수 공법에 의한 압밀침하에 관한 연구)

  • Park, Sung Zae;Jung, Du Hwoe;Jeong, Gyeong Hwan;Lee, Kyeong Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1243-1251
    • /
    • 1994
  • The implicit finite difference program was developed to evaluate the relationship between time and consolidation ratio within the zone of vertical drain effective radius. In the evaluation, the excess pore water pressure was considered to dissipate in two directions, namely, vertical and radial flow direction. To calculate subsoil stress increments in the soil due to multi-step embanking, the foundation soil was assumed to be an isotropic and homogeneous elastic medium and the initial excess pore water pressure was estimated by using Skempton's parameters whose condition is plane strain and elastic phase of pore pressure response within the soft ground. Regarding to the settlement estimation, immediate and primary consolidation settlements were calculated. The secondary or delayed consolidation settlement was not considered. Numerically calculated excess pore water pressure and settlements were similar to the measured data in situ. Thus, this method can be used to predict the time-consolidation ratio of each layer treated by vertical drain method.

  • PDF

Effect of the Overlapping Smear Zone on the Consolidation of Clayey Soil (스미어 영역 겹침이 점성토 지반의 압밀에 미치는 영향)

  • Yune, Chan-Young;Kim, Beom-Jun;Kang, Hee-Woong
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.4
    • /
    • pp.13-22
    • /
    • 2013
  • To simulate the soft ground improved by vertical drain method and to investigate the effect of overlapping smear on subsequent consolidation behavior, a series of consolidation tests with a large consolidation chamber and mandrel insertion device were conducted. Based on the test result, numerical analysis was also performed to analyze the efficiency of the vertical drain method. Laboratory test and numerical analysis results showed that the effect of smear zone increased consolidation settlement but the overlapping smear zone decreased the consolidation settlement. In addition, vertical drain accelerated consolidation rate but narrowing the drain spacing did not affect the consolidation rate because of the effect of smear. The efficiency of consolidation rather decreased substantially when the smear zone was overlapped.

Optimization Techniques for Soil Parameters used in Axisymmetric Nonlinear Consolidation Analysis (축대칭 비선형 압밀해석을 위한 지반정수값의 최적화기법)

  • 김윤태;이승래
    • Geotechnical Engineering
    • /
    • v.12 no.4
    • /
    • pp.131-144
    • /
    • 1996
  • In order to accelerate the rate of consolidation settlement and to gain a required shear strength for a given soft clay deposit, the preloadina technique combined with a vertical drainage system has been widely applied. Even if a sophisticated numerical analysis technique is applied to solve the consolidation behavior of drainage-installed soft deposits, the actual field behavior is often different from the behavior predicted in the design state due to several uncertainties involved in soil properties, numerical modelling, and measuring system. In this paper, two back-analysis schemes such hs simplex and BFGS methods have been implemented in an a Bisymmetric consolidation program, AXICON which considers the variation of compressibility and permeability during the consolidation process. Utilizing the program, one might be able to appropriately predict the subsequent consolidation behavior from the measured data in an early stage of consolidation of drainage-installed soft deposits.

  • PDF