• Title/Summary/Keyword: 배기 재순환 시스템

Search Result 54, Processing Time 0.036 seconds

A Fundamental Study of Hybrid Combustion System Applying Exhaust Gas Recirculation (배기가스 재순환을 적용한 하이브리드 연소시스템에 대한 기초 연구)

  • Oh, Wheesung;Yu, Byeonghun;Park, Taejoon;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.100-107
    • /
    • 2016
  • In this study confirmed the reduction effect of pollutant by applying Fi-EGR and FPI-EGR to hybrid combustion system realizing premixed flame and non-premxied flame at once. The results showed that NOx emission index decreased significantly in case of adopting EGR. Additionally, the hybrid combustion system with EGR resulted in a better performance compared to usual non-premixed combustion system such that it can reduce $NO_x$ emission at equivalent EGR ratios. Especially, in the case of 25% of FI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 50 : 50, NOx emission index reduction rate was about 59% compared to $NO_x$ emission of non-premixed combustion system without EGR and in the case of 15% of FPI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 70 : 30, $NO_x$ emission index reduction rate was about 48% compared to $NO_x$ emission of hybrid combustion system without EGR.

Improvement of Fuel Economy in a Diesel Engine by Application of Low Pressure EGR System (디젤 엔진의 연비 향상을 위한 저압 배기재순환 시스템의 적용에 관한 연구)

  • Kim, Yongrae;Lee, Yonggyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • LP(low pressure)-EGR system was investigated to evaluate its potential on fuel economy improvement and NOx emission reduction in a diesel engine. A diesel engine was tested for the evaluation of LP-EGR system at both of steady-state and transient test. For a transient test, control logic for LP-EGR valve operation was developed and a NEDC mode test was conducted by using a vehicle status simulation test. The steady-state results showed that LP-EGR system can reduce more NOx emission or fuel consumption comparing to the conventional HP(high pressure)-EGR. From the NEDC mode test, this LP-EGR system showed a possibility to improve fuel economy without a penalty of emissions.

$NO_x$ Control by Flue Gas Recirculation in Pulverized Coal Combustion (미분탄 연소에서 배기가스 재순환에 의한 질소산화물 제어)

  • 장길홍;장인갑;선칠영;천무환;양관모
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.473-474
    • /
    • 1999
  • 일반적으로 NOx배출은 연소과정에 의해 강력하게 지배되고 있으며, NOx 저감 기술은 1970년대 후반부터 많은 연구들이 수행되어, 그 이론들이 확립되고 있다. 석탄 연소시스템에서는 공기 다단(air staging, OFA), 연료다단(fuel staging, reburning) 및 배기가스 재순환(FGR) 등이 대표적인 NOx 저감 기술이며 [1∼4], 그 중 배기가스 재순환법은 저산소 배기가스를 연소용 공기에 재혼입시키므로써 NO의 생성속도를 저하시켜 NOx를 저감시키는 기법이다.(중략)

  • PDF

Effect of Recirculated Exhaust Gas on Exhaust Emissions of Boiler with FGR System (FGR 시스템 보일러의 배기 배출물에 미치는 재순환 배기의 영향)

  • Bae, Myung-Whan;Kim, Jung-Min;Kim, Yi-Suk;Cho, Yong-Soo;Choi, Seung-Chul
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.390-395
    • /
    • 2003
  • The effect of recirculated exhaust gas on exhaust emissions under four kinds of nozzle tip with the different fuel consumption rate are experimentally investigated by using an once-through boiler with FGR system. The purpose of this study is to develop the FGR control system for reducing NOx in a boiler. Intake and exhaust oxygen concentrations, and equivalence ratio are applied to discuss the effect of FGR rate on exhaust emissions at various fuel consumption rates. It is found that NOx emissions are decreased, while soot emissions are increased owing to the drop of intake and exhaust oxygen concentrations, and the rise of equivalence ratio as FGR rates are elevated.

  • PDF

Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in Power Plant Boilers with FGR System (FGR 시스템 공력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향)

  • Bae, Myung-Whan;Jung, Kwong-Ho;Choi, Seung-Chul;Cho, Yong-Soo;Kim, Yi-Suk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1686-1691
    • /
    • 2004
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air(OFA) damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_{x}$ emissions. To activate the combustion, the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$ , and the OFA with 0 to 20% into the flame is supplied, as the combustion air supplied to burner is reduced. It is found that the fuel consumption rate divided by evaporation rate does not show an obvious tendency to increase or decrease with rising the FOR rate, and $NO_{x}$ emissions are decreased, at the same OF A damper opening, as FOR rates are elevated and boiler loads are dropped.

  • PDF

A Study on the Effect of Recirculated Exhaust Gas upon Exhaust Emissions of Boiler with a FGR System (FGR 시스템 보일러의 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Jung, Kwang-Ho;Cho, Yong-Soo;Bae, Myung-Whan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.405-415
    • /
    • 2007
  • The effects of recirculated exhaust gas on exhaust emissions under four kinds of nozzle tip with the different fuel consumption rates are experimentally investigated by using an once-through boiler with a FGR system. The purpose of this study is to develop the FGR control system for reducing $NO_x$ emissions in boilers. Intake and exhaust oxygen concentrations, and equivalence ratio are considered to figure out the effect of FGR rate on exhaust emissions at various fuel consumption rates. It is found that $NO_x$ emissions are markedly decreased, while soot emissions are increased owing to the drop of intake and exhaust oxygen concentrations, and the rise of equivalence ratio as FGR rates are elevated. One can also conclude that the reduction in $NO_x$ emissions is more considerably influenced by the variation of equivalence ratio due to the FGR rate than the fuel consumption rate.

배기재순환과 기관성능 및 배기조성

  • 이성렬
    • Journal of the KSME
    • /
    • v.20 no.1
    • /
    • pp.21-30
    • /
    • 1980
  • 기관의 흡기에 배기의 일부를 혼입하는 배기재순환 (Exhaust Gas Recirculation, 약해서 EGR)은 배기중의 NOx 농도를 저하시키는 효과가 있기 때문에 자동차용 기관의 배기정화를 위한 유효한 수단의 하나로 생각된다. 배기가스의 공해성분인 CO, HC NOx 중에서 CO, HC는 실용적인 처 리방법이 각각 여러종류 개발되어 있지만 NOx를 기관으로부터 배출한 후의 단계에서 처리하는 실용적인 방법은 매우 어렵다, 따라서 이와 같은 단계에 있어서는 EGR를 유효하게 이용하는 것이 NOx 저감대책의 지름길이라 할 수 있다. 그러나 EGR를 시행하는 경우, 신기의 흡입량은 EGR에 의하여 제한을 받아 감소하므로 신기의 감소분만큼 출력이 저하하는 것을 막을 도리는 없다. 따라서 장래 대부분의 자동차용기관이 EGR시스템을 정착하게 되면 동력성능을 저하시 키지 않기 위하여 EGR에 상당하는 실린더용적의 증가를 하거나, 어떠한 대책이 필요할 것이다. 그러므로 저자는 장래 EGR시스템을 장착하게될 경우를 고려하는 기관에 EGR을 시해하는 경우, 기관사이클, 연소 및 배기성분 운전 Paramater와 EGR의 관계등에 대하여 기술하고저 한다.

  • PDF

A Study on Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in a Power Plant Boiler with FGR System (FGR 시스템 동력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Bae, Myung-whan;Jung, Kwong-ho;Park, Sung-bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.263-273
    • /
    • 2016
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_x$ emissions. To activate the combustion, the OFA with 0 to 20% is supplied into the flame. When the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$, also, the combustion air supplied to burner is changed. It is found that the fuel consumption rate per evaporation rate did not show an obvious tendency to increase or decrease with rising the FGR rate, and $NO_x$ emissions at the same OFA damper opening are decreased, as FGR rates are elevated and boiler loads are dropped. While a trace amount of soot is emitted without regard to the operation conditions of boiler load, OFA damper opening and FGR rate, because soot emissions are eliminated by the electrostatic precipitator with a collecting efficiency of 86.7%.

A study on the electronic EGR valve control method (전자식 EGR밸브 제어기법에 관한 연구)

  • Choi, Sang-Yun;Lee, Sang-Hun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2594-2602
    • /
    • 2014
  • As environmental awareness increases, regulations on exhaust gas of automobile, which is a cause of air pollution, have been strengthened. In order to meet emission regulation, automobile companies and engine manufacturers have actively developed the related technologies. Because the emission control has become severe, the systems using electronic motor or solenoid valve for high precise control are needed. For this reason, it is required not only the optimization of composition of components for improving performance and efficiency of the system but also the development of optimal design technology of electronic control system by securing the designing and manufacturing technology of the components. In this paper, it is proposed the position characteristics for electronic EGR valve module through the applied control logic and experiment results.

Fluid-flow Characteristics of Flue-gas-recirculation System in Sintering Plant (소결로 배기가스 재순환 시스템 내의 유체유동 특성 연구)

  • Moon, Chanhee;Kim, Hyun Dong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.7-15
    • /
    • 2018
  • The fluid-flow characteristics of flue-gas-recirculation (FGR) system can have a significant effect on system efficiency of a sintering plant. The flow characteristics in the system were investigated. A sintering plant with FGR system was modeled. Numerical visualization was performed and flow characteristics were analyzed. Characteristics of the flow distribution of the branch ducts, the inflow of air into the recirculating hood, and the flow in the hood were discussed. Based on the results three suggestions were proposed: (1) distribution of branch duct flowrate upstream, (2) installation of external air ducts in the hood, and (3) installation of baffles at the hood corners. The suggestions were tested numerical and experimental visualization methods. The suggestions were effective and confirmed to be applicable to the actual sinter plant.