• Title/Summary/Keyword: 배기 시스템

Search Result 740, Processing Time 0.028 seconds

The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology (가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발)

  • Park, Chan Il;Yoo, Kee-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2021
  • We devised the system to automatically shutdown the boiler and to fundamentally block the harmful gases, including carbon monoxide, into the indoor when the exhaust system swerves: (1) The discharge pressure of the exhaust gas decreases when the exhaust pipe is disconnected. The monitoring system of the exhaust pipe is implemented by measuring the output voltage of APS(Air Pressure Sensor) installed to control the amount of combustion air. (2) The operating software was modified so that when the system recognizes the fault condition of a flue pipe, the boiler control unit displays the fault status on the indoor regulator while shutting down the boiler. In accordance with the ventilation facility standards in the "Rules for Building Equipment Standards" by the Ministry of Land, Infrastructure and Transport, experiments were conducted to ventilate indoor air. When carbon monoxide leaked in worst-case scenario, it was possible to prevent poisoning accidents. However, since 2013, the number of indoor air exchange times has been mitigated from 0.7 to 0.5 times per hour. We observed the concentration exceeding TWA 30 ppm occasionally and thus recommend to reinforce this criterion. In conclusion, if the flue pipe fault detection and the indoor air ventilation system are introduced, carbon monoxide poisoning accidents are expected to decrease significantly. Also when the manufacturing and inspection steps, the correct installation and repair are supplemented with the user's attention in missing flue, it will be served to prevent human casualties from carbon monoxide poisoning.

Hydrogen Pumping Characteristics of a Scroll Pump (스크롤 펌프의 수소 배기특성)

  • In S. R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.14-23
    • /
    • 2006
  • The scroll pump is widely used in ultra clean vacuum systems. However, there is no commonly available information on the hydrogen pumping characteristics of this pump, which creates a difficulty in determining whether the scroll pump can be used or not in a fusion experiment system where hydrogen ,is the main working gas. In this paper the experimental setup, measurement procedures, experimental results, and discussions on the pumping speed, the maximum compression ratio and the back-streaming properties of the scroll pump, especially for the hydrogen gas, are reported.

The Application and Fabrication Process of Cold Cathode Lamp Using a FEA (FEA를 이용한 Cold Cathode Lamp의 제작 공정 연구와 그 응용성)

  • Park, Suhg-Hyun;Hong, Kun-Jo;Jun, Seok-Hwan;Kwon, Sang-Jik;Lee, Neung-Hun;Park, Jae-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1800-1802
    • /
    • 2000
  • 본 연구에서는 냉음극 발광 소자인 FEA를 이용하여 Cold Cathode Lamp 제작과 그 구조에 대해서 연구하였다. Anode plate에는 ZnO:Zn 형광체를 전기영동법으로 증착한 후 tube slabs와 anode plate를 frit glass를 이용하여 접합하였다. FEA와 substrate의 bonding, addressing을 위한 wire bonding, substrate와 집속전극, setter를 stem base의 외부전극에 연결하기 위한 spot welding, tube와 stem base를 glass melting method로 접합 공정을 하였다. 진공배기 시스템에 배기판을 연결하여 ${\sim}10^{-7}$torr까지 배기한 후 heater를 이용하여 배기관을 tip-off하였다. 최종적으로 진공을 유지하기 위해 getter를 RF 고주파로 활성화하였다. 결론적으로 lamp외 특성을 비교분석한 후 휘도 및 발광효율을 향상시키기 위한 구조절 개선과 방안을 고찰하였다.

  • PDF

Study on the Control Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층공동주택 국소배기용 입상덕트시스템의 제어성능평가에 관한 연구)

  • Kwon, Yong-Il;Ahn, Jung-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.103-108
    • /
    • 2009
  • Local exhaust system used in toilet and cooking place of low-rise public house installed roof ventilator at terminal of stack. There are many high riser public houses in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser public house depends on stack effect. But Neutral pressure level represents in a terminal of stack with air tightness for the best exhaust efficiency. Thereby, lower floors have the worst indoor air quality. This paper focuses mainly on the exhaust efficiency improved by roof fan with motor installed in high riser public house. It is observed there is higher exhaust efficiency than the existing natural roof ventilator.

A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting (조명발열 배기시스템의 배기위치에 따른 배기열량 실험연구)

  • Oh, Byung-Kil;Chung, Min-Ho;Won, Jong-Seo;Lee, Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • This study aims to reduce cooling energy by grasping kinds of heating load in building in order to decrease cooling energy in summer and eliminate efficiently heating load. Lighting heating value was confirmed through examination and experiment concerning lighting heating and reducible exhaustion value was extracted lighting apparatus. The optimal exhaust system by air conditioning type was suggested for applying lighting heat exhaust system and the method contributing to promotion supplying low energy architecture was suggested by predicting reduced cooling load.

진공펌프 배기속도 측정 방식에 따른 구조적 오차 및 보정

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.169-169
    • /
    • 2011
  • 진공펌프의 성능을 나타내는 여러 파라미터가 있지만 가장 중요한 성능지표는 역시 배기속도라고 할 수 있다. 배기속도는 물리적으로 체적유량(volume flow rate, L/s 또는 m3/hr) 즉 단위시간당 펌프 흡기구에 들어오는 기체의 체적을 가리킨다. 펌프 흡기구 단면을 지나가는 체적을 직접 측정하는 것은 거의 불가능하므로 진공 전문가들은 흡기구로 들어가는 기체 유량(flow rate, mbar${\cdot}$L/s 또는 Pa${\cdot}$m3/s)과 흡기구 압력(mbar 또는 Pa)을 측정한 후 유량을 압력으로 나누어 주는 방식으로 배기속도를 측정한다. 유량은 표면 기체 방출을 고려하더라도 실용적인 측면에서 보면 위치에 상관없이 불변하는 값으로 볼 수 있어서 유량을 어떻게 정밀하게 잴 것인가 하는 방법만 있으면 편리한 위치에서 측정하면 된다. 반면에 압력을 정밀하게 측정하는 방식은 확립되어 있지만 막상 어디서 측정하는 것이 옳은가 하는 것은 의외로 쉽지 않다. 펌프의 배기속도를 측정하는 상황을 몇 가지로 가정해 보면, 규격에 입각한 표준용기에 달아 정식으로 재는 것, 게이지가 부착된 마구리판을 달고 간이로 재는 것, 펌프가 사용되고 있는 시스템 현장에서 재는 것이 있을 수 있고 펌프가 달려 있는 상태도 직접 용기에 달거나, 도관 또는 어댑터 및 밸브를 통해 달리는 경우가 있다. 앞에서 펌프 배기속도 계산 시 사용하는 흡기구 압력이란 엄밀히 말하면 흡기구를 바라보는 방향으로 가해지는 압력을 말하는데 이는 진공 게이지를 펌프 흡기구 면에서 상류를 향하도록 놓을 때 얻을 수 있는 값으로 막상 실행하는 것은 어렵다. 표준용기의 구조는 진공 게이지를 특정 위치에 달 때 마치 흡기구 면에 놓인 게이지처럼 흡기구 압력을 정확하게 측정할 수 있도록 고안된 것이지만 때에 따라서는 여러 변형된 측정 방식을 사용할 수밖에 없는 상황이 만들어지므로 어떤 보정을 거치면 올바른 배기속도 값을 구할 수 있는지 살펴볼 필요가 있다.

  • PDF